Service Manuals, User Guides, Schematic Diagrams or docs for : . Car Manuals Subaru Legacy 1995-1999 Approved Subaru Legacy 1995 1995 Service Manual ENGINE SECTION FUEL INJECTION SYSTEM MSA5TCD95L5505

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
MSA5TCD95L5505


>> Download MSA5TCD95L5505 documenatation <<

Text preview - extract from the document
2-7                        SERVICE PROCEDURE
8. Rear Oxygen Sensor


                                   8. Rear Oxygen Sensor
                                   A: REMOVAL
                                   1) Lift-up the vehicle.
                                   2) Disconnect connector from rear oxygen sensor.




                         B2M0335


                                   3) Apply SUBARU CRC or its equivalent to threaded por-
                                   tion of rear oxygen sensor, and leave it for one minute or
                                   more.
                                   SUBARU CRC (Part No. 004301003)




                                   4) Remove rear oxygen sensor.
                                   CAUTION:
                                   When removing rear oxygen sensor, do not force rear
                                   oxygen sensor especially when exhaust pipe is cold,
                                   otherwise it will damage exhaust pipe.




                         B2M0351


                                   B: INSTALLATION
                                   1) Before installing rear oxygen sensor, apply anti-seize
                                   compound only to threaded portion of rear oxygen sensor
                                   to make the next removal easier.
                                   Anti-seize compound:
                                      SS-30 by JET LUBE
                                   CAUTION:
                                   Never apply anti-seize compound to protector of rear
                                   oxygen sensor.
                        B2M0352A


                                   2) Install rear oxygen sensor.
                                   Tightening torque:
                                      21