Service Manuals, User Guides, Schematic Diagrams or docs for : . Car Manuals Subaru Legacy 1995-1999 Approved Subaru Legacy 1995 1995 Service Manual MECHANICAL COMPONENTS SECTION AIR CONDITIONING SYSTEM MSA5TCD95L5736

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
MSA5TCD95L5736


>> Download MSA5TCD95L5736 documenatation <<

Text preview - extract from the document
   SERVICE PROCEDURE                                                 4-7
                                14.Evaporator - 15. Condenser Fan Assembly


           3) Disconnect the connection between the expansion
           valve and pipe from receiver drier.
           4) Remove the expansion valve from pipes.
           5) To install expansion valve, reverse removal procedures.
           Properly wrap capillary tube of expansion valve with seal.
           6) Check to see if the evaporator fins are clogged. If they
           are, clean them with compressed air.
           CAUTION:
           Water must never be used to clean the evaporator.
B4M0101A
           7) Check parts that have been removed for cracks or
           scratches, and repair or replace them with new ones, if
           necessary.
           8) Reassemble the evaporator in the reverse order of dis-
           assembly.
           NOTE:
           Confirm that the O-ring is inserted in the specified position.




           15. Condenser Fan Assembly
           A: REMOVAL AND INSTALLATION
           1) Disconnect battery negative terminal.
           2) Disconnect harness connector from fan motor.
           3) Remove condenser fan bolt from radiator.
           4) Pull condenser fan assembly.
           5) Install the condenser fan assembly in the reverse order
           of removal.
B4M0102A   Tightening torque:
               T: 7.4