>> Download MSA5TCD96L6398 documenatation <<Text preview - extract from the document6-2 DIAGNOSTICS
2. AT Shift Lock System
2. AT Shift Lock System
A: WIRING DIAGRAM
B6M0466
66
DIAGNOSTICS 6-2
2. AT Shift Lock System
B: BASIC DIAGNOSTICS CHART
Turn ignition switch ON.
Check that shift lever does not move from "P" to any Not OK Conduct diagnostics procedure No. 1.
OK
Check if shift lever moves from "P" to any other Not OK Conduct diagnostics procedure No. 2.
OK
Move shift lever to "N" and turn ignition switch OFF.
Check that ignition key cannot be removed from slot Not OK
Conduct diagnostics procedure No. 3.
OK
Check if ignition key can be removed with shift lever Not OK
Conduct diagnostics procedure No. 4.
OK
System is OK.
67
6-2 DIAGNOSTICS
2. AT Shift Lock System
C: DIAGNOSTICS PROCEDURE No. 1
Not OK
Check that stop lights do not remain on when brake Check stop light system.
pedal is released.
OK
Disconnect connector from shift lock control module.
Check that shift lock does not occur when shift lever Not OK Replace shift lock control module.
is moved to "P".
OK
Disconnect connector from "P" position switch.
Disconnect connector from shift lock solenoid.
Not OK
Check that shift lock does not occur when shift lever Short in wiring harness of shift lock solenoid.
is moved to "P".
OK
Check selector lever assembly.
68
DIAGNOSTICS 6-2
2. AT Shift Lock System
D: DIAGNOSTICS PROCEDURE No. 2 (SHIFT
LOCK DOES NOT RELEASE.)
Not OK
Check if stop light comes on when brake pedal is Check stop light system.
depressed.
OK
Not OK
Check if voltage between shift lock control module Repair or replace wiring harness or faulty connector
terminal No. 4 and body is at least 10 V when brake between stop light switch and shift lock control
pedal is depressed. module.
OK
Not OK
Check if voltage between shift lock control module Check fuse.
terminal No. 1 and body is at least 10 V when Repair or replace wiring harness or faulty connector
ignition switch is turned ON. between ignition switch and shift lock control
module.
OK
Turn ignition switch OFF.
Disconnect connector from shift lock control module.
Not OK
Check if continuity exists between terminal No. 2 of Check inhibitor switch or repair wiring harness.
shift lock control module connector and body when
shift lever is set at "P".
OK
Not OK
Check if continuity exists between terminal No. 5 of Check "P" position switch or repair wiring harness.
shift lock control module connector and body when
shift lever is set at "P".
OK
Measure resistance between terminal No. 1 of shift
lock control module connector and body.
Not OK
Resistance is less than 20 . Shift lock solenoid circuit is shorted. Repair or
replace wiring harness or faulty connector between
OK shift lock solenoid and shift lock control module.
Not OK
Resistance is at least 10 . Shift lock solenoid is shorted or poorly grounded.
* After repairs, recheck solenoid operation.
OK If still faulty, replace shift lock control module.
Not OK
Check if resistance between terminal No. 10 of shift Shift lock control module ground circuit open or poor
lock control module connector and body is less than connector contact.
10 .
OK
Replace shift lock control module.
69
6-2 DIAGNOSTICS
2. AT Shift Lock System
E: DIAGNOSTICS PROCEDURE No. 3 (KEY
INTERLOCK DOES NOT OPERATE.)
Not OK
Check if shift lock operates properly. Check diagnostics procedure "No. 1" or "No. 2".
OK
Not OK
Check if voltage between shift lock control module Faulty key switch.
terminal No. 8 and body is at least 10 V when Repair or replace wiring harness or faulty connector
ignition key is inserted in its slot. between fuse box and shift lock control module.
OK
Check if voltage between shift lock control module Not OK Repair or replace wiring harness or faulty connector
terminal No. 7 and body is at least 10 V when between ignition switch and shift lock control
ignition switch is set to ACC. module.
OK
Disconnect connector from shift lock control module. Not OK
Key lock solenoid circuit open. Repair or replace
Check if resistance between terminal No. 9 and wiring harness or faulty connector between key lock
terminal No. 11 of shift lock control module solenoid and shift lock control module.
connector is less than 8 .
OK
Voltage is at least 4 V. (*) Not OK
Key lock solenoid is shorted.
Repair or replace wiring harness or faulty connector
OK between key lock solenoid and shift lock control
module.
Not OK * After repairs, recheck for proper operation.
Check if resistance between terminal No. 11 of shift
lock control module connector and body is at least 1 If still faulty, replace shift lock control module.
M.
OK
Replace shift lock control module.
*: When conducting operational checks of the key lock solenoid, do not apply 12 V to solenoid for more than one second, since
this may break solenoid circuit.
70
DIAGNOSTICS 6-2
2. AT Shift Lock System
F: DIAGNOSTICS PROCEDURE No. 4 (KEY
INTERLOCK DOES NOT RELEASE.)
Not OK
Check if shift lock operates properly. Check diagnostics procedure "No. 1" or "No. 2".
OK
Not OK
Check if voltage between shift lock control module Faulty key switch. Repair or replace wiring harness
terminal No. 8 and body is at least 10 V when or faulty connector between fuse box and shift lock
ignition key is inserted in its slot. control module.
OK
Check if voltage between shift lock control module Not OK Repair or replace wiring harness or faulty connector
terminal No. 7 and body is at least 10 V when between ignition switch and shift lock control
ignition switch is set to ACC. module.
OK
Disconnect connector from shift lock control module. Not OK
Key lock solenoid circuit open.
Check if resistance between terminal No. 9 and Repair or replace wiring harness or faulty connector
terminal No. 11 of shift lock control module between key lock solenoid and shift lock control
connector is less than 8 . (*) module.
OK
Voltage is at least 4 V. Not OK
Key lock solenoid is shorted.
Repair or replace wiring harness or faulty connector
OK between key lock solenoid and shift lock control
module.
* After repairs, recheck for proper operation.
If still faulty, replace shift lock control module.
Check if resistance between terminal No. 9 of shift Not OK
Repair or replace wiring harness or faulty connector
lock control module connector and body is at least 1 between key lock solenoid and shift lock control
M. module.
* After repairs, recheck for proper operation.
OK If still faulty, replace shift lock control module.
Replace shift lock control module.
*: When conducting operational checks of the key lock solenoid, do not apply 12 V to solenoid for more than one second, since
this may break solenoid circuit.
71