Service Manuals, User Guides, Schematic Diagrams or docs for : . Car Manuals Subaru Legacy 1995-1999 Approved Subaru Legacy 1996 1996 Service Manual MECHANICAL COMPONENTS SECTION AIR CONDITIONING SYSTEM MSA5TCD96L6251

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
MSA5TCD96L6251


>> Download MSA5TCD96L6251 documenatation <<

Text preview - extract from the document
4-7                    SERVICE PROCEDURE
10. Performance Test


                           10. Performance Test
                           1. VEHICLE SET UP
                           In order to obtain meaningful test results, the vehicle must
                           be set up to meet the following conditions:
                           1) Vehicle in shade
                           2) No wind
                           3) All vehicle doors closed
                           4) Front windows opened
                           5) Hood opened
                           6) Engine speed set at 1,500 rpm.
                           7) A/C ON
                           8) Temperature control lever -- Maximum cold
                           9) Air source -- Recirculation
                           10) Blower speed -- 4th position (High)
                           11) Operate A/C for 10 minutes (Minimum) before taking
                           measurement.

                           2. MEASUREMENTS
                           After 10 minutes (Minimum) of A/C operation and using
                           accurate test equipment, take the following measurements
                           (in order):
                           1) Evaporator intake air temperature at recirculation door.
                           2) Evaporator discharge air temperature at center grill.
                           3) Condenser (Ambient) intake air temperature measured
                           0.9 m (3 ft) in front and in line with the center of the con-
                           denser.
                           4) Suction (Low) side pressure
                           5) Discharge (High) side pressure
                           NOTE:
                           If only one thermometer is available; 1) take the ambient
                           measurement first; then 2) the intake air; and 3) dis-
                           charge air temperature.




                                 28
SERVICE PROCEDURE                                        4-7
                                          10. Performance Test


    3. MEASUREMENT STANDARD BY VERSES
    Compare temperature and pressure measurements with
    the established standards shown in the following charts.