Text preview - extract from the document
   SERVICE PROCEDURE                                                 4-7
                                    16. Flexible Hose - 17. Relay and Fuse


           16. Flexible Hose
           A: REMOVAL AND INSTALLATION
           1) Disconnect battery negative terminal.
           2) Discharge refrigerant using refrigerant recovery system.
           
           3) Remove low-pressure hose.
               (1) Remove hose attaching bolts.
           CAUTION:
 B4M0103
           Plug the opening to prevent foreign matter from get-
           ting in.
               (2) Disconnect the connector at evaporator module.
           4) Remove high-pressure hose.
               (1) Disconnect hose attaching bolt (compressor side).
               (2) Disconnect hose attaching bolt (condenser side).
           CAUTION:
           Plug the opening to prevent foreign matter from get-
           ting in.
           5) Installation is in the reverse order of removal.
 B4M0764
           6) Charge refrigerant. 
           17. Relay and Fuse
           A: LOCATION
           Relays used with A/C system are located as shown in fig-
           ure.
           1) A/C relay
           2) Main fan (radiator fan) relay
           3) Sub fan (condenser fan) relay
           4) Sub fan (condenser fan) water temperature relay
G4M0649
           5) Fuses (10 A and 20 A)

           B: INSPECTION
           1) Check conduction with a circuit tester (ohm range)
           according to the following table in figure.




G4M0651


           2) Replace relays which do not meet specifications.