>> Download MSA5TCD96L6235 documenatation <<Text preview - extract from the document4-6 SERVICE PROCEDURE
5. Intake Door Motor
5. Intake Door Motor
A: REMOVAL
1) Disconnect GND cable from battery.
2) Remove glove box and pocket back panel.
3) Remove heater duct or evaporator. (With A/C model).
B5M0025
4) Remove intake unit from the vehicle.
G4M0561
5) Remove screws which secure intake door motor to
intake unit.
NOTE:
Ensure that RECIRC switch is set to "ON".
G4M0562
B: INSPECTION
1) When approx. 12 V is applied to the intake door motor
terminals, intake door motor operates as follows:
LHD model
Intake Terminal
door motor Intake door motor operation
position
FRESH 2 Door motor moved to FRESH position.
3
B4M0294A RECIRC 1 Door motor moved to RECIRC position.
RHD model
Intake Terminal
door motor Intake door motor operation
position
FRESH 1 Door motor moved to FRESH position.
2
RECIRC 3 Door motor moved to RECIRC position.
16
SERVICE PROCEDURE 4-6
5. Intake Door Motor
2) Connect harness to intake door motor.
3) Turn ignition switch to "ACC" and RECIRC switch to
"ON" then, set to "RECIRC".
NOTE:
Ensure that intake door motor is set in the "RECIRC" mode.
4) Install intake door motor on intake unit.
5) Secure rod holder to link, and install link to intake unit.
6) Manually set rod in the "RECIRC" mode, and secure to
rod holder.
G4M0564
7) Operate mode selector switch to ensure that system
changes from intake air to "RECIRC" and from "RECIRC"
to intake air in full-stroke range.
C: INSTALLATION
Installation is in the reverse order of removal.