Service Manuals, User Guides, Schematic Diagrams or docs for : . Car Manuals Subaru Legacy 1995-1999 Approved Subaru Legacy 1996 1996 Service Manual WIRING DIAGRAM SECTION WIRING DIAGRAM MSA5TCD96L6475

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
MSA5TCD96L6475


>> Download MSA5TCD96L6475 documenatation <<

Text preview - extract from the document
6-3                                     WIRING DIAGRAM
2. Basic Diagnostics Procedures


                                            2. Basic Diagnostics Procedures
                                            The most important purpose of diagnostics is to determine
                                            which part is malfunctioning quickly, to save time and labor.
                                            A: IDENTIFICATION OF TROUBLE SYMPTOM
                                            Determine what the problem is based on the symptom.

                                            B: PROBABLE CAUSE OF TROUBLE
                                            Look at the wiring diagram and check the system's circuit.
                                            Then check the switch, relay, fuse, ground, etc.

                                            C: LOCATION AND REPAIR OF TROUBLE
                                            1) Using the diagnostics narrow down the causes.
                                            2) If necessary, use a voltmeter, ohmmeter, etc.
                                            3) Before replacing certain component parts (switch, relay,
                                            etc.), check the power supply, ground, for open wiring
                                            harness, poor connectors, etc. If no problems are
                                            encountered, check the component parts.

                                            D: CONFIRMATION OF SYSTEM OPERATION
                                            After repairing, ensure that the system operates properly.




                                            E: INSPECTION
                                            1. VOLTAGE MEASUREMENT
                                            1) Using a voltmeter, connect the negative lead to a good
                                            ground point or negative battery terminal and the positive
                                            lead to the connector or component terminal.
                                            2) Contact the positive probe of the voltmeter on connec-
                                            tor (A).
                                            The voltmeter will indicate a voltage.
                                            3) Shift the positive probe to connector (B). The voltmeter
                                  G6M0206
                                            will indicate no voltage.
                                            With test set-up held as it is, turn switch ON. The voltme-
                                            ter will indicate a voltage and, at the same time, the light
                                            will come on.
                                            4) The circuit is in good order. If a problem such as a lamp
                                            failing to light occurs, use the procedures outlined above to
                                            track down the malfunction.




                                                   8
      WIRING DIAGRAM                                                     6-3
                                               2. Basic Diagnostics Procedures


          2. CIRCUIT CONTINUITY CHECKS
          1) Disconnect the battery terminal or connector so there is
          no voltage between the check points.
          Contact the two leads of an ohmmeter to each of the check
          points.
          If the circuit has diodes, reverse the two leads and check
          again.
          2) Use an ohmmeter to check for diode continuity.
          When contacting the negative lead to the diode positive
G6M0207   side and the positive lead to the negative side, there should
          be continuity.
          When contacting the two leads in reverse, there should be
          no continuity.




          3) Symbol "o--o" indicates that continuity exists between
          two points or terminals. For example, when a switch posi-
          tion is "3", continuity exists among terminals 1, 3 and 6, as
          shown in table below.
                            Terminal
                                       1   2        3      4      5      6
          Switch Position
                     OFF
                      1                k                          k      k
                      2                k                   k             k
                      3                k            k                    k
                      4                k   k                             k




                 9
6-3                                     WIRING DIAGRAM
2. Basic Diagnostics Procedures


                                            3. HOW TO DETERMINE AN OPEN CIRCUIT
                                            1) Voltmeter method
                                            An open circuit is determined by measuring the voltage
                                            between respective connectors and ground using a
                                            voltmeter, starting with the connector closest to the power
                                            supply. The power supply must be turned ON so that cur-
                                            rent flows in the circuit. If voltage is not present between a
                                            particular connector and ground, the circuit between that
                                            connector and the previous connector is open.
                                  G6M0208


                                            2) Ohmmeter method
                                            Disconnect all connectors affected, and check continuity in
                                            the wiring between adjacent connectors. When the ohm-
                                            meter indicates "infinite", the wiring is open.




                                  G6M0209

                                            4. HOW TO DETERMINE A SHORT-CIRCUIT
                                            1) Test lamp method
                                            Connect a test lamp (rated at approximately 3 watts) in
                                            place of the blown fuse and allow current to flow through
                                            the circuit. Disconnect one connector at a time from the
                                            circuit, starting with the one located farthest from the power
                                            supply. If the test lamp goes out when a connector is
                                            disconnected, the wiring between that connection and the
                                            next connector (farther from the power supply) is shorted.
                                  G6M0210


                                            2) Ohmmeter method
                                            Disconnect all affected connectors, and check continuity
                                            between each connector and ground. When ohmmeter
                                            indicates continuity between a particular connector and
                                            ground, that connector is shorted.




                                  G6M0211