>> Download MSA5TCD97L3929 documenatation <<Text preview - extract from the document BRAKES 4-4b
5. Control Module I/O Signal
5. Control Module I/O Signal
1. I/O SIGNAL VOLTAGE
Input/Output signals
Contents Connector No. Terminal No.
Measured value and measuring conditions
Front left wheel P7 1--11 0.12 -- 1 V (When it is 10 Hz.)
ABS
sensor Front right wheel P6 8--16 0.12 -- 1 V (When it is 10 Hz.)
(Wheel
speed Rear left wheel P6 7--15 0.12 -- 1 V (When it is 10 Hz.)
sensor)
Rear right wheel P7 2--12 0.12 -- 1 V (When it is 10 Hz.)
Front left outlet P4 1--GND
Front right outlet P5 3--GND 10 -- 14 V when the valve is OFF.
Rear left outlet P5 8--GND Less than 1.5 V when the valve is ON.
Rear right outlet P4 3--GND
Solenoid Front left inlet P4 2--GND
valve Front right inlet P5 2--GND 10 -- 14 V when the valve is OFF.
Rear left inlet P5 7--GND Less than 1.0 V when the valve is ON.
Rear right inlet P4 4--GND
TCS 1 P4 5--GND 10 -- 14 V when the valve is OFF.
Hydraulic TCS 2 P5 6--GND Less than 1.0 V when the valve is ON.
unit
Valve power supply P6 6--GND Ignition switch ON, 10 -- 14 V
Valve relay power supply P6 1--GND Less than 1.2 V when IGN is ON.
10 -- 14 V when the system is down.
Motor relay power supply P6 9--GND Less than 1.0 V when the motor is ON.
10 -- 14 V when the motor is OFF.
P7 3--GND Cyclic waveform of more than 180 Hz
Motor sensor signals when the motor across terminals is ON.
P7 13--GND Less than 70 Hz when the motor is OFF.
H/L toggle signal with the brake pedal off
(Cycle 14 mS, H: 10 --14 V, L: less than
Pressure switch P7 6--GND 0.7 V). 10 -- 14 V with the brake pedal
depressed.
Pedal Output signals P7 5--GND 0.7 -- 0.9 V with the brake pedal off.
stroke
sensor Power supply P7 4--14 5