Text preview - extract from the document
                                       SERVICE PROCEDURE                                            [W9B1] 4-7
                                                                                                    9. Lubrication


7. CHECK THE EVAPORATOR                                      9. Lubrication
ASSEMBLY
1) Use one or both of the following methods to
                                                             A: ADJUSTMENT
check the evaporator assembly.                               1. SYSTEM OIL STABILIZATION
2) Remove the drain hose from the case drain                 1) Prior to opening the refrigerant system for
nipple. Hold the probe at the end of the case drain          repairs (except compressor seizure) the system
nipple for at least 10 seconds. Be certain to recon-         must be stabilized for correct oil replenishment.
nect the drain hose when finished.                           2) Follow these procedures:
3) With the ignition key in the "ACC" position, run             (1) Engine speed set to 1,500 rpm
the blower on high speed for 1 minute, then turn                (2) A/C "ON"
the blower off. Place the probe in the center instru-           (3) Air source to recirculate
ment panel vent, an turn the blower on low speed                (4) Blower in 4th or high speed position
for 1 to 2 seconds, then turn the blower off. Leave          