                                                                                                             AC-89
                            AIR CONDITIONING          -     HEATER CONTROL ASSEMBLY (Manual A/C)


                                          HEATER CONTROL ASSEMBLY
                                          (Manual A/C)                                                        AC3F4-01


                                          ON-VEHICLE INSPECTION
                                          1.    INSPECT HEATER CONTROL LEVER AND DIALS OP-
                                                ERATION
                                          Move the control dials left and right check for stiffness and bind-
                                          ing the full range of the dials.
                                          2.    REMOVE HEATER CONTROL ASSEMBLY
                                          3.    INSPECT AMPLIFIER CIRCUIT
                                          (a) Remove the glove compartment door
                                                (See page BO-69 ).




                                          (b)      Disconnect the amplifier connector and inspect the con-
Wire Harness Side:
                                                   nector on wire harness side, as shown in the chart below.
                                                   Test conditions:
                                                          S    Turn ignition switch to ON
                                                          S    Blower speed switch HI
                                                          S    Temperature control lever Max. COOL



                              I21759




        Tester connection                       Condition                              Specified condition
           1 - Ground                            Always                                 Battery voltage
           2 - Ground                  Turn ignition switch to ON                       Battery voltage
           2 - Ground              Turn ignition switch to OFF                             No voltage
            11 - 13                              Always                                     4.5 - 5.5
            15 - 16              Turn light control switch to TAIL                      Battery voltage
            15 - 16              Turn light control switch to OFF                          No voltage




2002 4RUNNER (RM887U)

                                                                    Author :            Date :                1858
AC-90
                            AIR CONDITIONING        -    HEATER CONTROL ASSEMBLY (Manual A/C)

                                       (c)      Disconnect the amplifier connector and inspect the con-
 Wire Harness Side:
                                                nector on wire harness side, as shown in the chart below.
                                                Test conditions:
                                                       S    Turn ignition switch to ON
                                                       S    Blower speed switch HI
                                                       S    Temperature control lever Max. COOL



                              I21758




        Tester connection                    Condition                              Specified condition
           1 - Ground                         Always                                    Below 1 




2002 4RUNNER (RM887U)

                                                                Author :              Date :              1859
                                                                                                             AC-91
                             AIR CONDITIONING         -     HEATER CONTROL ASSEMBLY (Manual A/C)

                                          (d)      Connect the connector to amplifier and inspect wire har-
From back side:
                                                   ness side connector from the back side, as shown in the
                                                   chart below.
                                                   Test conditions:
                                                          S    Running engine at idle speed
                                                          S    Blower speed switch HI
                                                          S    A/C switch ON
                                                          S    Temperature control lever Max. COOL
                                I21756




        Tester connection                       Condition                              Specified condition
           3 - Ground                            IG ON.                                    10 -14 V
           3 - Ground       IG ON. Disconnect pressure switch connector                   Below 1.0 V
           4 - Ground              IG ON. Set temp. MAX. COOL                             Below 1.0 V
           4 - Ground               IG ON. Set temp. MAX. HOT                             Below 1.0 V
           5 - Ground               IG ON. Set temp. MAX. HOT                             Below 1.0 V
           5 - Ground              IG ON. Set temp. MAX. COOL                             Below 1.0 V
           6 - Ground             IG ON. Air inlet selector: FRESH                        Below 1.0 V
           6 - Ground         IG ON. Air inlet selector: RECIRCULATE                       10 - 14 V
           7 - Ground         IG ON. Air inlet selector: RECIRCULATE                      Below 1.0 V
           7 - Ground             IG ON. Air inlet selector: FRESH                         10 - 14 V
           8 - Ground               IG ON. Operate blower motor                            10 - 14 V
           9 - Ground                     A/C switch to OFF                                4.5 - 5.5 V
           9 - Ground                     A/C switch to ON                                 4.5 - 5.5 V
          10 - Ground                     A/C switch to ON                                Below 1.0 V
          10 - Ground                     A/C switch to OFF                               Below 1.0 V
          14 - Ground                     A/C switch to ON                                 10 - 14 V
          14 - Ground                     A/C switch to OFF                                10 - 14 V
          17 - Ground                    Mode selector: FACE                              Below 1.0 V
          17 - Ground               Mode selector: Except FACE                             10 - 14 V
          18 - Ground                     Mode selector: B/L                              Below 1.0 V
          18 - Ground                Mode selector: Except B/L                             10 - 14 V
          19 - Ground                    Mode selector: FOOT                              Below 1.0 V
          19 - Ground               Mode selector: Except FOOT                             10 - 14 V
          20 - Ground                     Mode selector: F/D                              Below 1.0 V
          20 - Ground                Mode selector: Except F/D                             10 - 14 V
          21 - Ground                    Mode selector: DEF                               Below 1.0 V
          21 - Ground                Mode selector: Except DEF                             10 - 14 V
          23 - Ground               Ambient temp. 25 