Text preview - extract from the document
                                                                                                                       BE-163
                                     BODY ELECTRICAL      -   ENGINE IMMOBILISER SYSTEM


ENGINE IMMOBILISER SYSTEM
                                                                                                                        BE11U-04


REGISTRATION PROCEDURE
HINT:
In case of having lost all the already registered master keys, you are not able to do additional registration
or deletion. Change the ECM and then must register the new key codes according to the following registra-
tion procedure of the automatic registration mode.
1.    KEY REGISTRATION IN AUTOMATIC REGISTRATION MODE
(a) Registration of a new transponder key.
HINT:
 S    This must be done when you install a new ECM.
 S    The new ECM is on the automatic key code registration mode. The already fixed number of key codes
      for this ECM can be registered.
      On this type of vehicle, up to 3 key codes can be registered.
 S    In the automatic registration mode, the last key registered becomes sub-key.



                                  START                                    Security indicator blinks until the first
                                                                           key is inserted. The indicator lights up
                                                                           after the key registration.


                    Insert the key in the key cylinder.
                                                                               Security Indicator ON


                           Under registration

                                                                               Security Indicator OFF


                         Registration completion




                            Remove the key.



                                                                           Security Indicator light is ON
                                                                           (After the last key (sub-key) has
           Yes            Will you register the
                                                                           been registered, the indicator
                          next key?
                                                                           remain OFF until remove the
                                                                           key. And after remove the key,
                                       No                                  the indicator blinks.)


                                   END




 2002 4RUNNER (RM887U)

                                                                    Author :                   Date :                    1631
BE-164
                                         BODY ELECTRICAL   -   ENGINE IMMOBILISER SYSTEM

HINT:
S       When a key is not inserted in the key cylinder on the automatic registration mode, the security indicator
        always lights on.
S       When the immobiliser system operates normally and the key is pull out, the security indicator blinks.
S       When key code registration could not be performed on the automatic registration mode, code 2-1 is
        output from the security indicator and when inserting the already registered key, code 2-2 is output.
       Blinks                        Code 2-1                                           Code 2-2
      1.8 sec.          0.25 sec.    1 sec.                          0.25 sec.         1 sec.




    0.2 sec.        0.25 sec. 0.5 sec.                            0.25 sec. 0.5 sec.




(b)     Automatic registration mode completion
        If completing the mode forcibly when more than 1 key code have been registered on the automatic
        registration mode, perform the following procedures.
        After 1 more key code have been registered with master key, perform step (1) or (2) without pulling
        the key out or inserting the already registered key.
        (1) Depress and release brake pedal 5 times or more within 15 sec.
        (2) With the hand-held tester, require automatic registration mode completion.




 2002 4RUNNER (RM887U)

                                                                      Author :                  Date :      1632
                                                                                                         BE-165
                                    BODY ELECTRICAL     -   ENGINE IMMOBILISER SYSTEM

2.    REGISTRATION OF ADDITIONAL MASTER KEY
There are 2 ways for registration of additional master key, one way is depressing brake pedal and accelera-
tion pedal and the other way is using hand-held tester.
HINT:
 S    It is possible to register up to 7 master key codes including the already registered key code.
 S    When any operation time described below is over, registration mode completes.
 S    When the next procedure is performed while the timer is working, the timer completes counting time,
      then next timer starts.
 S    When replacing "Ignition Cylinder Key Set" or "Lock Cylinder Set" and register according to the follow-
      ing procedure using the original master key. However, after the registration of the additional master
      key, as the original master key and the original sub-key is not necessary any more, so erase registra-
      tion of those key codes.
      (1) Depressing brake pedal and acceleration pedal:



                             Insert already registered master key in the key
                             cylinder



                             Depress and release the acceleration pedal 5               Within 15 sec.
                             times.


                                                                                        Within 20 sec.
                             Depress and release the brake pedal 6 times,
                             and remove the master key.


                                                                                        Within 10 sec.
                             Insert key to be registered in key cylinder.



                                                                                        Within 10 sec.
                             Depress and release the acceleration pedal 1
                             time. (Security indicator blinks)
  Within 10 sec.

                             After 60 sec. additional master key is registered.
                             (Security indicator is OFF)




                          Yes           Will you register the
                                        next key?

                                                      No

                             The registration mode completes when pulling
                             out the key and depressing and releasing the
                             brake pedal once or more within 10 secs. after
                             indicator has been off or 10 sec. have passed.

 2002 4RUNNER (RM887U)

                                                                   Author :             Date :             1633
BE-166
                                      BODY ELECTRICAL      -   ENGINE IMMOBILISER SYSTEM

    (2)    Using hand-held tester:


            Insert already registered master key in the key cylinder
            and turn the ignition switch ON.




             Using hand-held tester select master key registration.




                                                                                  Within 20 sec.

            Remove the master key.




                                                                                  Within 10 sec.
            Insert key to be registered in key cylinder.
            (Security indicator blinks)




            After 60 sec., additional master key is registered.
            (Security indicator OFF)




                 The registration mode completes when pulling
                 out the key and depressing and releasing the
                 brake pedal once or more within 10 sec. after in-
                 dicator has been off or 10 sec. have passed.


          HINT:
          Please follow the screen of the hand-held tester for more detailed procedure.




2002 4RUNNER (RM887U)

                                                                       Author :                Date :   1634
                                                                                                   BE-167
                                    BODY ELECTRICAL      -   ENGINE IMMOBILISER SYSTEM

3.    REGISTRATION OF ADDITIONAL SUB-KEY
There are 2 ways for registration of additional sub-key, one way is depressing brake pedal and acceleration
pedal and the other way is using hand-held tester.
HINT:
 S    It is possible to register up to 3 sub-key codes including the already registered key code.
 S    When any operation time described below is over, registration mode completes.
 S    When the next procedure is performed while the timer is working, the timer completes counting time,
      then next timer starts.
      (1) Depressing brake pedal and acceleration pedal:
                        Insert already registered master key in the key
                        cylinder


                                                                                 Within 15 sec.
                        Depress and release the acceleration pedal 4
                        times.


                                                                                 Within 20 sec.
                        Depress and release the brake pedal 5 times,
                        and remove the master key.

                                                                                 Within 10 sec.

                        Insert key to be registered in key cylinder.


                                                                                  Within 10 sec.
                        Depress and release the acceleration pedal 1
                        time. (Security indicator blinks)
 Within 10 sec.


                        After 60 sec. additional sub-key is registered.
                        (Security indicator is OFF)




                     Yes           Will you register the
                                   next key?

                                                 No

                        The registration mode completes when pulling
                        out the key and depressing and releasing the
                        brake pedal once or more within 10 sec. after in-
                        dicator has been off or 10 sec. have passed.




2002 4RUNNER (RM887U)

                                                                   Author :              Date :      1635
BE-168
                                     BODY ELECTRICAL       -   ENGINE IMMOBILISER SYSTEM

    (2)   Using hand-held tester:

            Insert already registered master key in the key cylinder
            and turn the ignition switch ON.




            Using hand-held tester select sub-key registration.




                                                                                  Within 20 sec.

            Remove the master key.




                                                                                  Within 10 sec.

            Insert key to be registered in key cylinder.
            (Security indicator blinks)




           After 60 sec., additional sub-key is registered.
           (Security indicator OFF)




               The registration mode completes when pulling
               out the key and depressing and releasing the
               brake pedal once or more within 10 sec. after in-
               dicator has been off or 10 sec. have passed.



          HINT:
          Please follow the screen of the hand-held tester for more detailed procedure.




2002 4RUNNER (RM887U)

                                                                       Author :                Date :   1636
                                                                                                      BE-169
                                      BODY ELECTRICAL      -   ENGINE IMMOBILISER SYSTEM

4.    ERASURE OF TRANSPONDER KEY CODE
There are 2 ways for erasure of transponder key code, one way is depressing brake pedal and acceleration
pedal and the other way is using hand-held tester.
HINT:
 S    Delete all other master and sub-key codes leaving the master key code to use the operation. When
      using the key which was used before deletion, it is necessary to register the code again.
 S    When any operation time described below is over, registration mode completes.
 S    When the next procedure is performed while the timer is working, the timer completes counting time,
      then next timer starts.

     (1)   Depressing brake pedal and acceleration pedal:



             1. Insert already registered master key in the key cylinder.



                                                                                     Within 15 sec.
             2. Depress and release the acceleration pedal 6 times.



                                                                                     Within 20 sec.
             3. Depress and release the brake pedal 7 times.


                                                                                     Within 10 sec.
             4. Remove the master key.




                                      END
                               (Key code erased)



            HINT:
            When the key cannot be pulled out in the step 4, key code deletion is canceled.




2002 4RUNNER (RM887U)

                                                                     Author :              Date :       1637
BE-170
                                     BODY ELECTRICAL     -   ENGINE IMMOBILISER SYSTEM

    (2)   Using hand-held tester:


            1. Insert already registered master key in the key cylinder
               and turn the ignition switch ON.




            2. Require key code deletion from hand-held tester.
            (Security indicator blinks)



                                                                                  Within 10 sec.

            3. Remove the master key.




                                      END
                               (Key code erased)



           HINT:
           S When the key cannot be pulled out in step 3, key code deletion is canceled.
              (Security indicator is OFF.)
           S Please follow the screen of the hand-held tester for more detailed procedure.




2002 4RUNNER (RM887U)

                                                                     Author :            Date :    1638