Text preview - extract from the document
DI-578
                                          DIAGNOSTICS   -   AIR CONDITIONING SYSTEM
                                                                                                                  DI5CD-01


PRE-CHECK
1.    LIST OF OPERATION METHODS
By operating each of the A/C control switches as shown in the diagram below, it is possible to enter the diag-
nosis check mode.


             Turn ignition switch ON with AUTO and
             R/F switches held down.


                                                                          If both AUTO switch and R/F switch
                                                                          are not pressed at the same time.

               Indicator Check


                                             R/F
    OFF             DTC Check                                                                               OFF
                   (Sensor Check)                               AUTO             Actuator Check
                (continuous operation)                                        (continuous operation)

                           DEF                                                              DEF

                                             R/F                 R/F
                     DTC Check                                                                             OFF
    OFF                                                                           Actuator Check
                   (Sensor Check)             AUTO              AUTO
                 (stepped operation)                                            (stepped operation)


                           DEF                                                           DEF


                                         Cancel check mode and can start
                                         A/C control


                                                                                : Indicates a switch operation.




 2002 4RUNNER (RM887U)

                                                                   Author :               Date :                    754
                                                                                                              DI-579
                                          DIAGNOSTICS      -   AIR CONDITIONING SYSTEM

                                                 2.      INDICATOR CHECK
    R/F Switch                                   (a)     Turn the ignition switch to ON while pressing the air condi-
                                                         tioning control AUTO switch and R/F switch simulta-
                                                         neously.




  AUTO Switch
                                        I09224



Blinking Pattern                                 (b)     Check that all the indicators light up and go off at 1 second
                                                         intervals 4 times in succession.
                       4 times
                                                 HINT:
         1 sec.
                   1 sec.                        S       After the indicator check is ended, the system enters the
                                                         DTC begins automatically.
  ON
                                                 S       Press the OFF switch when desiring to cancel the check
                                                         mode.
 OFF

                                        I00339



                                                 3.      DTC CHECK (SENSOR CHECK)
            Code Display                         (a)     Perform an indicator check. After the indicator check is
                                                         completed, the system enters the DTC check mode auto-
                                                         matically.
                                                 (b)     Read the code displayed on the panel. Refer to the list of
                                                         DTCs on page DI-582 when reading the DTCs. (DTCs
                                                         are output at the temperature display).

                                        I09224



                                                 (c)     If the slower display is desired, press the front DEF switch
                            Front DEF Switch
                                                         and change it to stepped operation. Each time the front
                                                         DEF switch is pressed, the display changes by 1 step.




                                        I09224




2002 4RUNNER (RM887U)

                                                                     Author :              Date :               755
DI-580
                                  DIAGNOSTICS   -   AIR CONDITIONING SYSTEM


 No. 1 J/B                              4.    CLEARING DTC
                                        (a)   Pull out the ECU-B fuse in No. 1 J/B for 10 sec., or longer
                                              to clear the DTC memory.
                        ECU-B Fuse      (b)   After reinserting the fuse, check that the normal code is
                                              output.




                               I09233




2002 4RUNNER (RM887U)

                                                           Author :             Date :              756
                                                                                                              DI-581
                                         DIAGNOSTICS        -   AIR CONDITIONING SYSTEM

                                                 5.      ACTUATOR CHECK
   R/F Switch            Front DEF Switch        (a)     After entering the DTC check mode (Sensor Check
                                                         Mode) press the R/F switch.
                                                 (b)     Since each damper, motor and relay automatically oper-
                                                         ates at 1 second intervals beginning in order from 10 in
                                                         the temperature display, check the temperature and air
                                                         flow visually and by hand.
                    OFF Switch                           If a slower display is desired, press the FRONT DEF
                                       I09224            switch and change it to a stepped operation. Each time
                                                         the FRONT DEF switch is pressed, the display changes
                                                         by 1 step.
                                                 HINT:
                                                  S      Code are displayed in order from the smaller to the larger
                                                         numbers.
                                                  S      To cancel the check mode, press the Off switch.



             Display                                               Conditions
 Step No.
             code       Blower motor            Air flow vent      Air inlet damper Magnetic clutch   Air mix damper

                                                  FACE                                    OFF          Cool side
    1           0            OFF                                      FRESH
                                                                                                      (0 % open)

                                                  FACE                FRESH                            Cool side
    2           1             1                                                           OFF
                                                                                                      (0 % open)

                                                                      FRESH               ON           Cool side
    3           2            16                   FACE
                                                                                                      (0 % open)
                                                                                                       Cool side
    4           3            16                   FACE               FRS/REC              ON
                                                                                                      (0 % open)
                                                                                                        Cool / Hot
    5           4            16                   FACE               RECIRC               ON           (50 % open)
                                                                                                        Cool / Hot
    6           5            16                 BI-LEVEL             RECIRC               ON
                                                                                                       (50 % open)
                                                                                                        Hot side
    7           6            16                   FOOT               RECIRC               ON
                                                                                                      (100 % open)
                                                                                                        Hot side
    8           7            16                   FOOT               RECIRC               ON
                                                                                                      (100 % open)

                                                                     RECIRC                             Hot side
    9           8            16                 FOOT/DEF                                  ON
                                                                                                      (100 % open)

    10                       31                       DEF            RECIRC               ON            Hot side
                9
                                                                                                      (100 % open)




2002 4RUNNER (RM887U)

                                                                      Author :             Date :              757