Text preview - extract from the document
DI-586
                                                      DIAGNOSTICS       -   AIR CONDITIONING SYSTEM
                                                                                                                                  DI3VX-02


PROBLEM SYMPTOMS TABLE
                              Symptom                                                       Suspect Area                     See page
                                                                   3. IG power source circuit                                DI-622
Whole functions of the A/C system does not operate.
                                                                   4. A/C control assembly                                   IN-28

                                                                   1.   Heater main relay circuit                            DI-627
                                                                   2.   Blower motor circuit                                 DI-630
Air Flow Control: No blower operation                              3.   Engine coolant temperature sensor circuit            DI-597
                                                                   4.   IG power source circuit                              DI-622
                                                                   5.   A/C control assembly                                 IN-28
                                                                   1. Blower motor circuit                                   DI-630
Air Flow Control: No blower control                                2. IG power source circuit                                DI-622
                                                                   3. Heater main relay circuit                              DI-627
Air Flow Control: Insufficient air out                             1. Blower motor circuit                                   DI-630
                                                                   1. Volume of refrigerant                                  AC-3
                                                                   2. Drive belt tension                                     AC-16
                                                                   3. Inspect refrigeration system with manifold gauge set   AC-3
                                                                   4. Compressor circuit                                     DI-632
                                                                   5. Pressure switch circuit                                DI-603
Temperature Control: No cool air comes out
                                                                   6. Air mix control servomotor circuit                     DI-612
                                                                   7. Air mix damper position sensor circuit                 DI-606
                                                                   8. Room temp. sensor circuit                              DI-588
                                                                   9. Ambient temp. sensor circuit                           DI-591
                                                                   10.A/C control assembly                                   IN-28
                                                                   1.   Air mix control servomotor circuit                   DI-612
                                                                   2.   Air mix damper position sensor circuit               DI-606
                                                                   3.   Ambient temp. sensor circuit                         DI-591
Temperature Control: No warm air comes out                         4.   Room temp. sensor circuit                            DI-588
                                                                   5.   Evaporator temp. sensor circuit                      DI-594
                                                                   6.   A/C control assembly                                 IN-28
                                                                   7.   Heater radiator (in heater unit)                     AC-34
                                                                   1. Volume of refrigerant                                  AC-3
                                                                   2. Drive belt tension                                     AC-16
                                                                   3. Inspect refrigeration system with manifold gauge set   AC-3
                                                                   4. Ambient temp. sensor circuit                           DI-591
                                                                   5. Evaporator temp. sensor circuit                        DI-594
                                                                   6. Solar sensor circuit                                   DI-600
                                                                   7. Air mix damper position sensor circuit                 DI-606
Temperature Control: Output air is warmer or cooler than the set   8. Engine coolant temp. sensor circuit                    DI-597
                 temperature or response is slow.                  9. Air mix control servomotor circuit                     DI-612
                                                                   10.Compressor                                             AC-49
                                                                   11.Condenser                                              AC-60
                                                                   12.Receiver                                               AC-57
                                                                   13.Evaporator                                             AC-29
                                                                   14.Heater radiator (in heater unit)                       AC-34
                                                                   15.Expansion valve                                        AC-24
                                                                   16.A/C control assembly                                   IN-28
                                                                   1. Air mix control servomotor circuit                     DI-612
Temperature Control: No temperature control
                                                                   2. Air mix damper position sensor circuit                 DI-606
                    (only Max. cool or Max. warm)
                                                                   3. A/C control assembly                                   IN-28
                                                                   1. Air outlet control servomotor circuit                  DI-619
No air outlet control
                                                                   2. A/C control assembly                                   IN-28

                                                                   1. Compressor circuit                                     DI-632
Engine idle up does not occur, or is continuous
                                                                   2. A/C control assembly                                   IN-28




2002 4RUNNER (RM887U)

                                                                                      Author :                      Date :          762
                                                                                                                     DI-587
                                                    DIAGNOSTICS       -   AIR CONDITIONING SYSTEM


                           Symptom                                                        Suspect Area            See page
Set temperature value displayed does not match up with operation
                                                                   1. A/C control assembly                         IN-28
of temperature control switch.
Brightness does not change when rheostat volume or light control   1. Illumination light system                    BE-15
switch is turned.                                                  2. A/C control assembly                         IN-28

Unable to access the diagnosis mode.                               A/C control assembly                            IN-28
DTC not recorded. Set mode is cleared when IG switch is turned     1. Back-up power source circuit                DI-625
off.                                                               2. A/C control assembly                        IN-28




2002 4RUNNER (RM887U)