                                                                                                                                         AC-3
                                                   AIR CONDITIONING         -   AIR CONDITIONING SYSTEM
                                                                                                                                          AC0PZ-01


                                                                ON-VEHICLE INSPECTION
                                                                1.  INSPECT REFRIGERANT VOLUME
                                                                Observe the sight glass on the liquid tube.
                                                                    Test conditions:
                                                                           S     Running engine at 1,500 rpm
                                                                           S     Blower speed control switch at "HI" position
                                                                           S     A/C switch ON
                                Sight Glass                                S     Temperature control dial at "COOL" position
                                                       N08744
                                                                           S     Fully open the doors
 Item                     Symptom                                     Amount of refrigerant                          Remedy
                                                                                                    (1) Check for gas leakage with gas leak de-
  1     Bubbles present in sight glass                    Insufficient*                             tector and repair if necessary
                                                                                                    (2) Add refrigerant until bubbles disappear
  2     No bubbles present in sight glass                 None, sufficient or too much              Refer item 3 and 4
                                                                                                    (1) Check for gas leakage with gas leak de-
        No temperature difference between com-
  3                                                       Empty or nearly empty                     tector and repair if necessary
        pressor inlet and outlet
                                                                                                    (2) Add refrigerant until bubbles disappear
        Temperature between compressor inlet and
  4                                                       Correct or too much                       Refer to items 5 and 6
        outlet is noticeably different
                                                                                                    (1) Discharge refrigerant
        Immediately after air conditioning is turned
  5                                                       Too much                                  (2) Evacuate air and charge proper amount
        off, refrigerant in sight glass stays clear
                                                                                                    of purified refrigerant
        When air conditioning is turned off, refriger-
  6                                                       Correct                                                        -
        ant foams and then stays clear

*: Bubbles in the sight glass with ambient temperatures higher than usual can be considered normal if cooling
is sufficient.




 1997 SUPRA (RM502U)

                                                                                         Author :              Date :                     2151
AC-4
                      AIR CONDITIONING    -   AIR CONDITIONING SYSTEM

                                 2.     INSPECT REFRIGERANT PRESSURE WITH MAN-
                                        IFOLD GAUGE SET
                                 This is a method in which the trouble is located by using a man-
                                 ifold gauge set. Read the manifold gauge pressure when these
                                 conditions are established.
                                        Test conditions:
                                               S    Temperature at the air inlet with the switch set
                                                    at RECIRC is 30 - 35 



◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo