                                                                                                                                     DI-193
                                                   DIAGNOSTICS        -   AUTOMATIC TRANSAXLE
                                                                                                                                         DI02Q-08




   DTC                  P1765                Linear Solenoid for Accumulator Pressure Control
                                             Circuit Malfunction (Shift Solenoid Valve SLN)


CIRCUIT DESCRIPTION
                                                          The shift solenoid valve SLN controls the hydraulic pressure
 Accumulator Control Pressure                             acting on the accumulator control valve when gears are shifted
                                                          and performs smooth gear shifting.
 High
                                                          The ECM determines optimum operating pressure according to
                                                          the signals from the throttle position sensor, vehicle speed sen-
                                                          sor and direct clutch speed sensor and controls the volume of
                                                          current flow to the solenoid valve.
                                                          The amount of current to the solenoid is controlled by the (*)
                                                          duty ratio of ECM output signals, causing a momentary change
                                                          to the hydraulic pressure acting on the clutches during gear
                                                          shifting.
                                                          When the duty ratio is high, the hydraulic pressure acting on the
        0                                                 clutches is low.
                                            1
              Electric Current (A)
                                      AT5608
(*) Duty Ratio
The duty ratio is the ratio of the period of continuity in one cycle.
For example, if A is the period of continuity in one cycle, and B is the period of non-continuity, then




                                                                                                                                         D00060

  DTC No.                        DTC Detecting Condition                                                Trouble Area
              After the engine is warmed up, the current flows to the shift
              solenoid valve SLN for 1 sec or more under condition (a) or     S Open or short in shift solenoid valve SLN circuit
  P1765       (b):                                                            S Shift solenoid valve SLN
              (a) Engine speed: 500 rpm or more                               S ECM
              (b) Park/neutral position switch: ON (P or N position)

Reference


            Waveform between terminals SLN+                                   Waveform between terminals SLN+
            and SLN- when engine is idling.                                   and SLN- during shift change.




                                                     5 V / Div.                                                             5 V / Div.

            GND                                                                  GND


                                                                                                 1 msec. / Div.
                         1 msec. / Div.                                                                                                  D00062




2001 SIENNA (RM787U)

                                                                               Author :                      Date :                      347
DI-194
                                          DIAGNOSTICS   -   AUTOMATIC TRANSAXLE

WIRING DIAGRAM


         E1                                                                                  ECM
         Transaxle


                                                                                   20
                                      3                 B-Y
                                                                                  E12 SLN+


                     Shift Solenoid
                     Valve SLN

                                                                                  19
                                      8                 G-W
                                                                                  E12 SLN-




                                                                                                   D07911




2001 SIENNA (RM787U)

                                                                  Author :          Date :         348
                                                                                                                         DI-195
                                       DIAGNOSTICS     -   AUTOMATIC TRANSAXLE

INSPECTION PROCEDURE

  1      Check shift solenoid valve SLN.


                        2
                                           Check solenoid resistance and operation:
                                   1
                                           PREPARATION:
                                           Disconnect the shift solenoid valve SLN connector.
                                           CHECK:
                                           (a) Measure resistance between terminals 1 and 2 of sole-
                                                noid connector.
                                           (b) Connect positive  lead with an 8 - 10 W bulb to terminal
                                                1 of solenoid connector and negative  lead to terminal
                                                2, then check the movement of the valve.
                                           OK:
                                                (a) Resistance: 5.1 - 5.5 
                         2     1                (b)
                                            When battery positive voltage is sup-       Valve moves in direction shown in il-
                                            plied.                                      lustration. (on the left)

                                                                                        Valve moves in direction shown in il-
                                            When battery positive voltage is cut off.
                                                                                        lustration. (on the right)

   (-)        (+)

                               D04720



                                           Check solenoid operation:
                                           PREPARATION:
                                           Connect positive  lead of the variable power supply to termi-
                                           nal 1 of solenoid connector and negative  lead to terminal 2.
                                           CHECK:
                                           (a) Check the movement of the valve when the voltage is
                                                 gradually increased.
                                                 (A current greater than 1A should not be supplied.)
  (+)
                                           (b) Check the movement of the valve when the voltage is cut
                                                 off.
                                           OK:
                         1      2                (a) As the voltage is increased, the valve should move
                                                 slowly in the       direction.
                                                 (b) The valve should return in the        direction.


  (-)


                               D00051
                                              NG           Replace the shift solenoid valve SLN.


  OK




2001 SIENNA (RM787U)

                                                                    Author :                    Date :                     349
DI-196
                                 DIAGNOSTICS   -   AUTOMATIC TRANSAXLE



   2     Check harness and connector between battery and shift solenoid valve SLN,
         shift solenoid valve SLN and ECM (See page IN-31 ).


                                       NG          Repair or replace the harness or connector.


  OK



  Check and replace the ECM
  (See page IN-31 ).