                                                                                                                                   DI-697
                                                      DIAGNOSTICS       -   AIR CONDITIONING SYSTEM
                                                                                                                                     DI3F3-05


PROBLEM SYMPTOMS TABLE
Front A/C
                              Symptom                                                        Suspect Area                       See page
                                                                   3. A/C control assembly                                      IN-31
Whole functions of the A/C system does not operate
                                                                   4. IG power source circuit                                   DI-749

                                                                   1.   IG power source circuit                                 DI-749
                                                                   2.   Front heater relay circuit                              DI-756
Air Flow Control: No blower operation
                                                                   3.   Blower motor circuit                                    DI-765
                                                                   4.   A/C control assembly                                    IN-31
                                                                   1. Blower motor circuit                                      DI-765
Air Flow Control: No blower control                                2. A/C control assembly                                      IN-31
                                                                   3. Solar sensor circuit                                      DI-715
Air Flow Control: Insufficient air flow                            Blower motor circuit                                         DI-765
                                                                   1. Refrigerant volume                                        AC-3
                                                                   2. Drive belt tension                                        AC-17
                                                                   3. Refrigeration system inspection with manifold gauge set   AC-3
                                                                   4. Compressor circuit                                        DI-776
                                                                   5. Pressure switch circuit                                   DI-721
Temperature Control: No cool air comes out
                                                                   6. Front air mix damper position sensor circuit              DI-727
                                                                   7. Front air mix damper control servomotor circuit           DI-736
                                                                   8. Front room temp. sensor circuit                           DI-712
                                                                   9. Ambient temp. sensor circuit                              DI-703
                                                                   10.A/C control assembly                                      IN-31
                                                                   1.   Front air mix damper position sensor circuit            DI-727
                                                                   2.   Front air mix damper control servomotor circuit         DI-736
                                                                   3.   Front room temp. sensor circuit                         DI-712
Temperature Control: No warm air comes out
                                                                   4.   Ambient temp. sensor circuit                            DI-703
                                                                   5.   Front evaporator temp. sensor circuit                   DI-706
                                                                   6.   A/C control assembly                                    IN-31

                                                                   1. Refrigerant volume                                         AC-3
                                                                   2. Drive belt tension                                        AC-17
                                                                   3. Refrigeration system inspection with manifold gauge set    AC-3
                                                                   4. Cooling fan system                                        AC-109
                                                                   5. Solar sensor circuit                                      DI-715
                                                                   6. Front room temp. sensor circuit                           DI-712
                                                                   7. Ambient temp. sensor circuit                              DI-703
                                                                   8. Front Evaporator temp. sensor circuit                     DI-706
Temperature Control: Output air is warmer or cooler that the set
                                                                   9. Front air mix damper position sensor circuit              DI-727
temperature or response is slow
                                                                   10.Front air mix damper control servomotor circuit           DI-736
                                                                   11.Front air inlet damper position sensor circuit            DI-730
                                                                   12.Front air inlet damper control servomotor circuit         DI-739
                                                                   13.Condenser                                                 AC-72
                                                                   14.Evaporator                                                AC-30
                                                                   15.Heater radiator                                           AC-77
                                                                   16.Expansion valve                                           AC-25
                                                                   17.A/C control assembly                                       IN-31




2001 SIENNA (RM787U)

                                                                                     Author :                    Date :              851
DI-698
                                                    DIAGNOSTICS       -   AIR CONDITIONING SYSTEM


                            Symptom                                                      Suspect Area                    See page
                                                                 1.   Front room temp. sensor circuit                    DI-712
                                                                 2.   Ambient temp. sensor circuit                       DI-703
Temperature Control: No temperature control (only Max. cool or
                                                                 3.   Front air mix damper position sensor circuit       DI-727
Max. warm)
                                                                 4.   Front air mix damper control servomotor circuit    DI-736
                                                                 5.   A/C control assembly                               IN-31
                                                                 1. Front air inlet damper position sensor circuit       DI-730
No air inlet control                                             2. Front air inlet damper control servomotor circuit    DI-739
                                                                 3. A/C control assembly                                 IN-31
                                                                 1. Air outlet damper control servomotor circuit         DI-744
No air flow control
                                                                 2. A/C control assembly                                 IN-31

                                                                 1. Compressor circuit                                   DI-776
Engine idle up does not occur, or is continuous
                                                                 2. ECM                                                  DI-19

                                                                 1. Igniter circuit                                      DI-754
A/C indicator blinking                                           2. Compressor lock sensor circuit                       DI-718
                                                                 3. A/C control assembly                                 DI-19




2001 SIENNA (RM787U)

                                                                                    Author :                    Date :         852
                                                                                                                                       DI-699
                                                             DIAGNOSTICS    -   AIR CONDITIONING SYSTEM

Rear A/C
                              Symptom                                                          Suspect Area                         See page
                                                                       1. IG power source circuit                                   DI-749
Whole functions of the rear A/C system does not operate
                                                                       2. A/C control assembly                                      IN-31

                                                                       1.   IG power source circuit                                 DI-749
                                                                       2.   Rear CLR relay circuit                                  DI-762
Air Flow Control: No blower operation (for rear cooling)
                                                                       3.   Rear blower motor circuit                               DI-768
                                                                       4.   A/C control assembly                                    IN-31

                                                                       1.   IG power source circuit                                 DI-749
                                                                       2.   Rear heater relay circuit                               DI-759
Air Flow Control: No blower operation (for rear heater)
                                                                       3.   Rear blower motor circuit                               DI-772
                                                                       4.   A/C control assembly                                    IN-31

                                                                       1. Rear blower motor circuit                                 DI-772
Air Flow Control: No blower control (for rear cooling)                 2. A/C control assembly                                      IN-31
                                                                       3. Solar sensor circuit                                      DI-715
                                                                       1. Rear blower motor circuit                                 DI-768
Air Flow Control: No blower control (for rear heater)                  2. A/C control assembly                                      IN-31
                                                                       3. Solar sensor circuit                                      DI-715
Air Flow Control: Insufficient air flow (for rear cooling)             1. Rear blower motor circuit                                 DI-768
Air Flow Control: Insufficient air flow (for rear heater)              1. Rear blower motor circuit                                 DI-768
                                                                       1. Refrigerant volume                                        AC-3
                                                                       2. Drive belt tension                                        AC-17
                                                                       3. Refrigeration system inspection with manifold gauge set   AC-3
                                                                       4. Expansion valve                                           AC-33
                                                                       5. Evaporator                                                AC-38
Temperature Control: No cool air comes out
                                                                       6. Compressor circuit                                        DI-776
                                                                       7. Rear air mix damper position sensor circuit               DI-733
                                                                       8. Rear air mix damper control servomotor circuit            DI-742
                                                                       9. Rear room temp. sensor circuit                            DI-712
                                                                       10.A/C control assembly                                      IN-31
                                                                       1.   Rear air mix damper position sensor circuit             DI-733
                                                                       2.   Rear air mix damper control servomotor circuit          DI-742
Temperature Control: No warm air comes out                             3.   Rear room temp. sensor circuit                          DI-712
                                                                       4.   Rear air intake temp. sensor circuit                    DI-724
                                                                       5.   A/C control assembly                                    IN-31
                                                                       1. Refrigerant volume                                         AC-3
                                                                       2. Drive belt tension                                        AC-17
                                                                       3. Refrigeration system inspection with manifold gauge set    AC-3
                                                                       4. Cooling fan system                                        AC-109
                                                                       5. Solar sensor circuit                                      DI-715
                                                                       6. Rear room temp. sensor circuit                            DI-712
Temperature Control: Output air is warmer or cooler that the set       7. Rear air intake temp. sensor circuit                      DI-724
temperature or response is slow                                        8. Rear air mix damper position sensor circuit               DI-733
                                                                       9. Rear air mix damper control servomotor circuit            DI-742
                                                                       10.Condenser                                                 AC-72
                                                                       11.Evaporator                                                AC-33
                                                                       12.Heater radiator                                           AC-51
                                                                       13.Expansion valve                                           AC-33
                                                                       14.A/C control assembly                                       IN-31
                                                                       1.   Rear room temp. sensor circuit                          DI-712
Temperature Control: No temperature control (only Max. cool or         2.   Rear air mix damper position sensor circuit             DI-733
Max. warm)                                                             3.   Rear air mix damper control servomotor circuit          DI-742
                                                                       4.   A/C control assembly                                    IN-31