Text preview - extract from the document
                                                                                                                        SF-35
                                                       SFI    -   MASS AIR FLOW (MAF) METER
                                                                                                                             SF0IX-03


       E2              THA    Ohmmeter           INSPECTION
                                                 1.   INSPECT MAF METER RESISTANCE
                                                 Using an ohmmeter, measure the resistance between terminals
                                                 THA and E2.
                                                      Resistance:
                                                             Terminals               Resistance              Temperature
                                                             THA - E2               13.6 - 18.4 k            -20 