Text preview - extract from the document
                                                                                                                    CO-29
                                                             COOLING   -   COOLING FAN RELAY


                                                             COOLING FAN RELAY                                       CO08H-01


                                                             INSPECTION
                                                             1.    INSPECT NO.1 COOLING FAN RELAY
                                                             (a)   Remove the No.1 cooling fan relay. (Marking: FAN NO.1)

                                      No.1 Cooling
                                      Fan Relay
                                                    B00742



Ohmmeter                                                     (b)    Inspect the No.1 cooling fan relay continuity.
                                              Continuity
       Continuity                                                   (1) Using an ohmmeter, check that there is continuity
                          1                                               between terminals 1 and 2.
                                      4                      If there is no continuity, replace the relay.
                                          Ohmmeter
                                                                    (2) Check that there is continuity between terminals 3
             3                                                            and 4.
                                                             If there is no continuity, replace the relay.
                      2

                                                    S04975



Ohmmeter No                                                  (c)    Inspect the No.1 cooling fan relay operation.
         Continuity                                                 (1) Apply battery voltage across terminals 1 and 2.
                  1                                                 (2) Using an ohmmeter, check that there is no continu-
                                      4                                   ity between terminals 3 and 4.
                                                             If there is continuity, replace the relay.
              3                                              (d) Install the No.1 cooling fan relay.

                      2
                                          Battery
                                                    S04976



                                                             2.    INSPECT NO.2 COOLING FAN RELAY
                                                             (a)   Remove the No.2 cooling fan relay. (Marking: FAN NO.2)




                                          No.2 Cooling
                                          Fan Relay

                                                    B00740



 Ohmmeter                         Continuity                 (b)    Inspect the No.2 cooling fan relay continuity.
                       4                                            (1) Using an ohmmeter, check that there is continuity
                                      2 Ohmmeter                          between terminals 1 and 2.
                  1                                          If there is no continuity, replace the relay.
                                          5
 Ohmmeter
                                                                    (2) Check that there is continuity between terminals 3
                                                                          and 4.
                                                             If there is no continuity, replace the relay.
                              3
                                                                    (3) Check that there is no continuity between terminals
                                    No Continuity
              Continuity                            S04972                3 and 5.
                                                             If there is continuity, replace the relay.
2001 SIENNA (RM787U)

                                                                                 Author :         Date :             1189
CO-30
                                                             COOLING   -   COOLING FAN RELAY

                                                             (c)    Inspect the No.2 cooling fan relay operation.
                       4                                            (1) Apply battery voltage across terminals 1 and 2.
                                       2 Ohmmeter                   (2) Using an ohmmeter, check that there is no continu-
                                                                          ity between terminals 3 and 4.
   Battery         1                    5
                                                             If there is continuity, replace the relay.
  Ohmmeter
                                                                    (3) Using an ohmmeter, check that there is continuity
                           3                                              between terminals 3 and 5.
                                                             If there is no continuity, replace the relay.
                                       Continuity
               No Continuity                        S04971   (d) Install the No.2 cooling fan relay.

                                                             3.    INSPECT NO.3 COOLING FAN RELAY
                                                             (a)   Remove the No.3 cooling fan relay. (Marking: FAN NO.3)




                                        No.3 Cooling
                                        Fan Relay
                                                    B00741




  Continuity                                                 (b)    Inspect the No.3 cooling fan relay continuity.
                                                                    (1) Using an ohmmeter, check that there is continuity
  Ohmmeter                         2        Ohmmeter
               1                                                          between terminals 1 and 2.
                                       5                     If there is no continuity, replace the relay.
                                                                    (2) Check that there is no continuity between terminals
                                                                          3 and 5.
                   3                                         If there is continuity, replace the relay.

                                   No Continuity
                                                    S04970



                                                             (c)    Inspect the No.3 cooling fan relay operation.
                               2
                                                                    (1) Apply battery voltage across terminals 1 and 2.
                                            Ohmmeter
               1                                                    (2) Using an ohmmeter, check that there is continuity
                                    5                                     between terminals 3 and 5.
                                                             If there is no continuity, replace the relay.
                                                             (d) Install the No.3 cooling fan relay.
                   3
    Battery
                                       Continuity
                                                    S04969




2001 SIENNA (RM787U)

                                                                                 Author :          Date :             1190