BE-142
                       BODY ELECTRICAL    -   GARAGE DOOR OPENER SYSTEM


                                 GARAGE DOOR OPENER SYSTEM                                      BE0G2-04


                                 REGISTRATION PROCEDURE
                                 1.    NEW CODE REGISTRATION
                                 NOTICE:
                                  S    If pressing the switch of the original transmitter to
                                       register the code, the system might operate.
                                  S    When registering the transmitter codes such as for
                                       garage or gate, check that there is nobody around
                                       those places then register.
                                 (a) Press the switch for the item to be registered for 20 se-
                                       conds
                                 HINT:
                                 When transferring to registration mode, LED (red) blinks in 1 Hz
                                 cycle.




                                 (b)   In the condition of (a), bring the original transmitter to with-
                                       in 1-inch area around the garage door opener and press
                                       the switch. (code transmitting).
                                 HINT:
                                 When code registration completes correctly, LED (red) blinks in
                                 5.6 Hz cycle.



                        I19481




2001 SIENNA (RM787U)

                                                     Author :               Date :                1660
                                                                                            BE-143
                       BODY ELECTRICAL   -   GARAGE DOOR OPENER SYSTEM

                               New code registration timing chart


           PRESSED
GARAGE DOOR
OPENER SWITCH
           PRESSED

               ENTER
                            20 sec
LEARN MODE
               EXIT

LED            ON
OPERATION
               OFF
                                                     LED flashes
                                                     at a rate of 1 Hz
                                                                                  LED flashes at a
                                                                                  rate of 5.6 Hz
               ON
ORIGINAL
TRANSMITTER
               OFF


                                                                                                I03487




                               If a code can not be registered, observe the following condi-
                               tions.
                               HINT:
                                S     If the battery of original transmitter is consumed.
                                S     Press the switch of the transmitter repeatedly in registra-
                                      tion mode, as some transmitters stop transmitting for 1 to
                                      2 seconds.
                                S     This system is not applicable to the garage door opener
                                      which had been made before 1982.
                               2.     CODE DELETION
                               (a) Press the switches at both ends of garage door opener
                                      simultaneously for 20 seconds.
                               HINT:
                               When transferring to deletion mode, LED (red) blinks in 6 Hz
                               cycle.
                               (b) When releasing the switch within 10 seconds after trans-
                                      ferring to deletion mode, all the registered codes will be
                                      erased.
                               HINT:
                               Press the switch until blinking in 6 Hz cycle stops, so that the
                               default code for check is set.




2001 SIENNA (RM787U)

                                                  Author :               Date :                1661
BE-144
                                  BODY ELECTRICAL   -   GARAGE DOOR OPENER SYSTEM

                                          Code deletion timing chart




 GARAGE DOOR            PRESSED
 OPENER SWITCH
 (Switch at either end)
                                       Enter in erase mode to erase all 3 channels
                        PRESSED
                       ON
 CLEAR/DEFAULT                                            10 SEC                 LOAD DEFAULT
                                       20 SEC
 MODE
                       OFF
                       ON
 LED
 OPERATION
                       OFF
                                                                         LED flashes at a rate of 6 HZ