Service Manuals, User Guides, Schematic Diagrams or docs for : . Car Manuals Toyota Sienna 1998-2003 Approved FSM 19 wdlcs repl
<< Back |
HomeMost service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download
Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing.
If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.
Image preview - the first page of the document
>> Download repl documenatation <<Text preview - extract from the document BE-89
BODY ELECTRICAL - WIRELESS DOOR LOCK CONTROL SYSTEM
BE0IO-06
REPLACEMENT
1. REPLACE TRANSMITTER (LITHIUM) BATTERY
NOTICE:
Special caution should be taken for handling each compo-
nent as they are precision electronic components.
(a) Using a screwdriver, remove the cover.
NOTICE:
Do not pry out the cover forcibly.
HINT:
Push the cover with a finger as shown in the illustration, so that
there becomes clearance, then pry out the cover from that
clearance.
(b) Remove the transmitter.
I09408 (c) Remove the battery (lithium battery).
NOTICE:
S Do not push the terminals with a finger.
S If prying up the battery (lithium battery) forcibly to re-
move, the terminals are deformed.
(d) Install a battery (lithium battery) as shown in the illustra-
tion.
NOTICE:
Face the battery upward. Take care not to deform the termi-
nals.
(e) Assemble the transmitter to the key plate and the cover.
I09406
2001 SIENNA (RM787U)
Author : Date : 1607
BE-90
BODY ELECTRICAL - WIRELESS DOOR LOCK CONTROL SYSTEM
2. REPLACE DOOR CONTROL RECEIVER AND TRANS-
MITTER
(a) Select the operation mode to perform from the following
operation modes.
S Rewrite mode
S Confirmation mode
HINT:
S The rewrite mode is used to erase all previously regis-
tered codes and register only new recognition codes.
S The confirmation mode is for confirming how many recog-
nition codes are already registered before you rewrite rec-
ognition codes.
(b) Follow the chart on the following page to register the
transmitter recognition code at the wireless door lock con-
trol receiver.
HINT:
S When procedure is out of the specified, the operation re-
turns to normal operation.
S Maximum 4 recognition codes can be registered.
2001 SIENNA (RM787U)
Author : Date : 1608
BE-91
BODY ELECTRICAL - WIRELESS DOOR LOCK CONTROL SYSTEM
Start registration of recognition code
The vehicle should be in the following conditions.
D The key is not inserted in the ignition key cylinder.
D Driver's door is OPEN. (Other doors are CLOSED)
D Driver's door is UNLOCKED. (Other doors are ignorable)
Insert the key into the ignition key cylinder, then pull it out.
Press the door lock control switch (by manual operation) 5 times to
LOCK/UNLOCK at approx. 1 sec. interval.
1st time 2nd time 3rd time 4th time 5th time
Approx. Approx.
Within 1 sec. 1 sec.
LOCK
40 secs.
OFF
UNLOCK
Close the driver's door, then open it.
Again press the door lock control switch (for manual operation) 5 times to
LOCK/UNLOCK at approx. 1 sec. interval.
1st time 2nd time 3rd time 4th time 5th time
Approx. Approx.
LOCK 1 sec. 1 sec.
Within OFF
40 secs.
UNLOCK
Insert the key into the ignition key cylinder.
2001 SIENNA (RM787U)
Author : Date : 1609
BE-92
BODY ELECTRICAL - WIRELESS DOOR LOCK CONTROL SYSTEM
Turn the ignition switch from ON to LOCK at approx. 1 sec. interval 2 to 3 times to select the mode.
Rewrite mode Confirmation mode
ON - LOCK change occurs 2 times ON - LOCK change occurs 3 times
Approx. Approx. Approx. Approx.
1 sec. 1 sec. 1 sec. 1 sec.
ON ON
LOCK LOCK
Pull out the key plate from the ignition key cylinder.
When confirmation
When rewrite mode is selected.
mode is selected.
Integration relay automatically performs the
Integration relay automatically performs LOCK-UNLOCK operation 1 to 4 times at
the LOCK-UNLOCK operation once or 2 sec. interval to inform the operator of
twice the number of the registered codes.
at 1 sec. interval to inform the operator HINT:
that rewrite mode has been selected. When the number of the registered code
is 0, the operation is automatically
Within LOCK-UNLOCK occurs twice performed 5 times.
3 secs. Indicates that rewrite mode has been
selected. Example:
1 sec. 1 sec. When the operation is performed twice, the
LOCK diagram shows that 2 type of recognition
UNLOCK code have been registered.
1st time 2nd time
2 secs. 2 secs.
LOCK
UNLOCK
Confirmation mode is completed.
2001 SIENNA (RM787U)
Author : Date : 1610
BE-93
BODY ELECTRICAL - WIRELESS DOOR LOCK CONTROL SYSTEM
Within
20 secs.
Press the LOCK and UNLOCK switch simultaneously for more than 1 sec.
Within
3 secs.
Press either the LOCK or UNLOCK switch for more than 1 sec.
Integration relay automatically performs LOCK-UNLOCK operation once or
twice at a 1 sec. interval to inform the operator that it has received the signal
from the transmitter.
LOCK-UNLOCK occurs once
Registration of recognition code is completed.
LOCK-UNLOCK occurs twice
Registration of recognition code has not been completed.
Within
D Recognition codes that were received first time and second time did not
3 secs.
match.
If they are not performed, the mode returns to the normal mode, then start with
"Start registration of recognition code".
Proceed to finish registration Proceed to continue registration
Within 20 secs.
If even one of the following conditions is satisfied, registration of recognition
codes is completed.
D 20 secs. have elapsed since the integration relay response.
D The driver's door is closed.
D The key plate is inserted in the ignition key cylinder.
D 4 types recognition codes are registratied at one time.
Registration of recognition codes (rewrite mode) is completed.
2001 SIENNA (RM787U)
Author : Date : 1611
◦ Jabse Service Manual Search 2026 ◦ Jabse Pravopis ◦ onTap.bg ◦ Other service manual resources online : Fixya ◦ eServiceinfo