                                                                                             BE-89
                       BODY ELECTRICAL     -   WIRELESS DOOR LOCK CONTROL SYSTEM
                                                                                               BE0IO-06


                                  REPLACEMENT
                                  1.   REPLACE TRANSMITTER (LITHIUM) BATTERY
                                  NOTICE:
                                  Special caution should be taken for handling each compo-
                                  nent as they are precision electronic components.




                                  (a) Using a screwdriver, remove the cover.
                                  NOTICE:
                                  Do not pry out the cover forcibly.
                                  HINT:
                                  Push the cover with a finger as shown in the illustration, so that
                                  there becomes clearance, then pry out the cover from that
                                  clearance.
                                  (b) Remove the transmitter.
                         I09408   (c) Remove the battery (lithium battery).
                                  NOTICE:
                                   S    Do not push the terminals with a finger.
                                   S    If prying up the battery (lithium battery) forcibly to re-
                                        move, the terminals are deformed.




                                  (d)   Install a battery (lithium battery) as shown in the illustra-
                                        tion.
                                  NOTICE:
                                  Face the battery upward. Take care not to deform the termi-
                                  nals.
                                  (e) Assemble the transmitter to the key plate and the cover.



                         I09406




2001 SIENNA (RM787U)

                                                    Author :              Date :               1607
BE-90
                       BODY ELECTRICAL   -   WIRELESS DOOR LOCK CONTROL SYSTEM

                               2.      REPLACE DOOR CONTROL RECEIVER AND TRANS-
                                       MITTER
                               (a)     Select the operation mode to perform from the following
                                       operation modes.
                                        S   Rewrite mode
                                        S   Confirmation mode
                               HINT:
                                S      The rewrite mode is used to erase all previously regis-
                                       tered codes and register only new recognition codes.
                                S      The confirmation mode is for confirming how many recog-
                                       nition codes are already registered before you rewrite rec-
                                       ognition codes.
                               (b)     Follow the chart on the following page to register the
                                       transmitter recognition code at the wireless door lock con-
                                       trol receiver.
                               HINT:
                                S      When procedure is out of the specified, the operation re-
                                       turns to normal operation.
                                S      Maximum 4 recognition codes can be registered.




2001 SIENNA (RM787U)

                                                    Author :             Date :              1608
                                                                                                              BE-91
                                    BODY ELECTRICAL      -   WIRELESS DOOR LOCK CONTROL SYSTEM


                       Start registration of recognition code




                       The vehicle should be in the following conditions.
                       D The key is not inserted in the ignition key cylinder.
                       D Driver's door is OPEN. (Other doors are CLOSED)
                       D Driver's door is UNLOCKED. (Other doors are ignorable)



                       Insert the key into the ignition key cylinder, then pull it out.




                       Press the door lock control switch (by manual operation) 5 times to
                       LOCK/UNLOCK at approx. 1 sec. interval.
                                1st time       2nd time        3rd time         4th time           5th time


                              Approx. Approx.
 Within                       1 sec.  1 sec.
               LOCK
 40 secs.
               OFF

            UNLOCK




                       Close the driver's door, then open it.




                       Again press the door lock control switch (for manual operation) 5 times to
                       LOCK/UNLOCK at approx. 1 sec. interval.
                                1st time       2nd time        3rd time         4th time        5th time


                              Approx. Approx.
               LOCK           1 sec.  1 sec.


 Within        OFF
 40 secs.
            UNLOCK




                       Insert the key into the ignition key cylinder.




2001 SIENNA (RM787U)

                                                                    Author :              Date :               1609
BE-92
                                         BODY ELECTRICAL   -     WIRELESS DOOR LOCK CONTROL SYSTEM




          Turn the ignition switch from ON to LOCK at approx. 1 sec. interval 2 to 3 times to select the mode.


            Rewrite mode                                       Confirmation mode


          ON - LOCK change occurs 2 times                  ON - LOCK change occurs 3 times


                          Approx. Approx.                         Approx. Approx.
                          1 sec. 1 sec.                           1 sec. 1 sec.

            ON                                      ON

         LOCK                                    LOCK




                       Pull out the key plate from the ignition key cylinder.
                                                                                                 When confirmation
                  When rewrite mode is selected.
                                                                                                 mode is selected.


                                                                           Integration relay automatically performs the
          Integration relay automatically performs                         LOCK-UNLOCK operation 1 to 4 times at
          the LOCK-UNLOCK operation once or                                2 sec. interval to inform the operator of
          twice                                                            the number of the registered codes.
          at 1 sec. interval to inform the operator                        HINT:
          that rewrite mode has been selected.                             When the number of the registered code
                                                                           is 0, the operation is automatically
  Within LOCK-UNLOCK occurs twice                                          performed 5 times.
  3 secs. Indicates that rewrite mode has been
          selected.                                                        Example:
                             1 sec. 1 sec.                                  When the operation is performed twice, the
                 LOCK                                                      diagram shows that 2 type of recognition
             UNLOCK                                                        code have been registered.
                                                                                             1st time 2nd time

                                                                                           2 secs. 2 secs.

                                                                                    LOCK
                                                                              UNLOCK




                                                                                Confirmation mode is completed.




2001 SIENNA (RM787U)

                                                                        Author :                Date :               1610
                                                                                                                 BE-93
                                       BODY ELECTRICAL     -   WIRELESS DOOR LOCK CONTROL SYSTEM




  Within
  20 secs.


                  Press the LOCK and UNLOCK switch simultaneously for more than 1 sec.

       Within
       3 secs.
                  Press either the LOCK or UNLOCK switch for more than 1 sec.




                 Integration relay automatically performs LOCK-UNLOCK operation once or
                 twice at a 1 sec. interval to inform the operator that it has received the signal
                 from the transmitter.
                  LOCK-UNLOCK occurs once
                       Registration of recognition code is completed.

                  LOCK-UNLOCK occurs twice

                      Registration of recognition code has not been completed.
     Within
                      D Recognition codes that were received first time and second time did not
     3 secs.
                         match.
                 If they are not performed, the mode returns to the normal mode, then start with
                 "Start registration of recognition code".

                                        Proceed to finish registration            Proceed to continue registration
                                                                                               Within 20 secs.

                  If even one of the following conditions is satisfied, registration of recognition
                  codes is completed.
                        D 20 secs. have elapsed since the integration relay response.
                        D The driver's door is closed.
                        D The key plate is inserted in the ignition key cylinder.
                        D 4 types recognition codes are registratied at one time.




                  Registration of recognition codes (rewrite mode) is completed.




2001 SIENNA (RM787U)

                                                                     Author :              Date :                 1611