                                                                                                                                           AC-3
                                                   AIR CONDITIONING           -   AIR CONDITIONING SYSTEM
                                                                                                                                            AC0RW-03


                                                                  ON-VEHICLE INSPECTION
                                                                  1.  INSPECT REFRIGERANT VOLUME
                                                                  Observe the sight glass on the liquid tube.
                                                                      Test conditions:
                                                                             S     Running engine at 1,500 rpm
                                                                             S     Blower speed control switch set at "HI"
                                                                             S     A/C switch ON
                                                                             S     Temperature control set at "MAX. COOL"
                            Sight Glass                  I03837
                                                                             S     Fully open doors
 Item                     Symptom                                       Amount of refrigerant                           Remedy
                                                                                                      (1) Check for gas leakage with gas leak de-
  1     Bubbles present in sight glass                      *Insufficient                             tector and repair if necessary
                                                                                                      (2) Add refrigerant until bubbles disappear
  2     No bubbles present i sight glass                    None, sufficient or too much              Refer to item 3 and 4
                                                                                                      (1) Check for gas leakage with gas leak de-
        No temperature difference between com-
  3                                                         Empty or nearly empty                     tector and repair if necessary
        pressor inlet and outlet
                                                                                                      (2) Add refrigerant until bubbles disappear
        Temperature between compressor inlet and
  4                                                         Correct or too much                       Refer to items 5 and 6
        outlet is noticeably different
                                                                                                      (1) Discharge refrigerant
        Immediately after air conditioning is turned
  5                                                         Too much                                  (2) Evacuate air and charge proper amount
        off, refrigerant in sight glass stays clear
                                                                                                      of new refrigerant
        When air conditioning is turned off, refriger-
  6                                                         Correct                                                           -
        ant foams and then stays clear

*: Bubbles in the sight glass with ambient temperatures higher than usual can be considered normal if cooling
is sufficient.
                                              2.     INSPECT REFRIGERANT PRESSURE WITH MAN-
                                                     IFOLD GAUGE SET
                                              This is a method in witch the trouble is located by using a man-
                                              ifold gauge set. Read the manifold gauge pressure when the
                                              these conditions are established.
                                                     Test conditions:
                                                            S    Temperature at the air inlet with the switch set
                                                                 at RECIRC is 30 - 35 