>> Download cip2716 documenatation <<Text preview - extract from the document05-626 DIAGNOSTICS - ELECTRONIC CONTROLLED AUTOMATIC
TRANSAXLE [ECT] 05280-11
DTC P2716 PRESSURE CONTROL SOLENOID "D"
ELECTRICAL (SHIFT SOLENOID SLT)
CIRCUIT DESCRIPTION
The throttle pressure that is applied to the primary regulator
valve (which modulates the line pressure) causes the solenoid
Line Pressure valve SLT, under electronic control, to precisely and minutely
Control Pressure
modulate and generate the line pressure according the extent
of the accelerator pedal depressed or the output of engine pow-
er.
This controls the line pressure and provides smooth shifting.
Current Flow to Solenoid D02290 Upon receiving a signal of the throttle valve opening angle, the
ECM controls the line pressure by sending a predetermined (*)
duty ratio to the solenoid valve, modulating the line pressure
and generating throttle pressure.
ON (*): Duty Ratio
The duty ratio is the ratio of the period of continuity in one cycle.
For example, if A is the period of continuity in one cycle, and B
OFF is the period of non-continuity, then
1 cycle
Duty Ratio=A/(A+B) x 100 (%)
BE4056
DTC No. DTC Detection Condition Trouble Area
Condition (a) or (b) below is detected 1 sec. or more:
S Open or short in shift solenoid valve SLT circuit
(1-trip detection logic)
P2716 S Shift solenoid valve SLT
(a) SLT- terminal: 0V
S ECM
(b) SLT- terminal: 12V
5 V/
Reference:
Division Check the waveform between terminals SLT+ and SLT- during
the engine idling.
GND
1 msec./Division D01875
2005 SIENNA REPAIR MANUAL (RM1163U)
Author : Date : 809
DIAGNOSTICS - ELECTRONIC CONTROLLED AUTOMATIC 05-627
TRANSAXLE [ECT]
MONITOR DESCRIPTION
When an open or short in the linear solenoid valve (SLT) circuit is detected, the ECM interprets this as a fault.
The ECM will turn ON the MIL and store the DTC.
MONITOR STRATEGY
Related DTCs P2716: Shift solenoid valve SLT/Range check
Required sensors/Components Shift solenoid valve SLT
Frequency of operation Continuous
Duration 1 sec.
MIL operation Immediate
Sequence of operation None
TYPICAL ENABLING CONDITIONS
The monitor will run whenever this DTC is not present. See page 05-9
Solenoid current cut status Not cut
Battery voltage 11 V or more
CPU commanded duty ratio to SLT 19% or more
Ignition switch ON
Starter OFF
TYPICAL MALFUNCTION THRESHOLDS
Solenoid status from IC Fail (Open or short)
COMPONENT OPERATING RANGE
Shift solenoid valve SLT Resistance: 5.0 to 5.6 at 20_C (68_F)
WIRING DIAGRAM
E1 Electronically Controlled
Transmission Solenoid ECM
2 13
G Y-R
E1 E7 SLT+
SLT+
8 12
GR Y-B
E1 E7 SLT-
SLT-
C93636
2005 SIENNA REPAIR MANUAL (RM1163U)
Author : Date : 810
05-628 DIAGNOSTICS - ELECTRONIC CONTROLLED AUTOMATIC
TRANSAXLE [ECT]
INSPECTION PROCEDURE
1 INSPECT TRANSMISSION WIRE(SLT)
(a) Disconnect the transmission wire connector from the
SLT+ transaxle.
(b) Measure the resistance between the terminals SLT+ and
SLT-.
OK:
Resistance: 5.0 to 5.6 at 20