                                                                                                           16-3
                                               COOLING   -   COOLING SYSTEM
                                                                                                          160M6-02


INSPECTION



                                               1.    INSPECT THERMOSTAT
                                               HINT:
                                               The thermostat is numbered with the valve opening tempera-
                                               ture.




                                      P13560



                                               (a)    Immerse the thermostat in water and gradually heat the
                                                      water.
                                               (b) Check the valve opening temperature of the thermostat.
                                                      Valve opening temperature:
                                                      80 to 84_C (176 to 183_F)
                                               If the valve opening temperature is not as specified, replace the
                                               thermostat.

                                      P00436



                                               (c)    Check the valve lift.
                                                      Valve lift: 10 mm (0.394 in.) or more at 95_C (203_F)
                                               If the valve lift is not as specified, replace the thermostat.
                                               (d) Check that the valve is fully closed when the thermostat
                                                      is at low temperatures (below 77_C (171_F)).
                                               If not closed, replace the thermostat.
                            10mm

                                      A51911



                                               2.  INSPECT WATER OUTLET CAP SUB-ASSY
                                               NOTICE:
                                                S  If the radiator cap has contaminations, rinse it with
                                                   water.
                                                S  Before using a radiator cap tester, wet the relief valve
                                                   and pressure valve with engine coolant or water.
                                                S  When performing steps (a) and (b) below, keep the
                                                   tester at an angle of over 30_ above the horizontal.




2005 SIENNA REPAIR MANUAL (RM1163U)

                                                                  Author :            Date :              2503
16-4
                                               COOLING   -   COOLING SYSTEM

                                               (a)     Using a radiator cap tester, slowly pump the tester and
                     Radiator Cap Tester               check that air is coming from the vacuum valve.
                                                       Pump speed: 1 push / 3 seconds or more
                                               NOTICE:
                                               Push the pump at a constant speed.
       30_ or more
                                               If air is not coming from the vacuum valve, replace the radiator
                                               cap.
 Radiator Cap                                  (b) Pump the tester and measure the relief valve opening
                                      A51912           pressure.
                                                       Pump speed: 1 push within 1 second
                                               NOTICE:
                                               The following pump speed is for the first pump only (in or-
                                               der to close the vacuum valve). After the first pump, the
                                               pump speed can be reduced.
                                                       Standard opening pressure:
                                                       83 to 113 kPa (0.85 to 1.15 kgf/cm2, 12.1 to 16.4 psi)
                                                       Minimum opening pressure:
                                                       69 kPa (0.7 kgf/cm2, 10.0 psi)
                                               If the opening pressure is less than minimum, replace the radia-
                                               tor cap.
                                               HINT:
                                               Use the tester's maximum reading as the opening pressure.




                                               3.     INSPECT WATER PUMP ASSY
              Turn                             (a) Visually check the drain hole for coolant leakage.
                                               If leakage is found, replace the water pump.
                                               (b) Turn the pulley, and check that the water pump bearing
                                                      moves smoothly and does not make noise.
                                               If necessary, replace the water pump.



                                      P12487




2005 SIENNA REPAIR MANUAL (RM1163U)

                                                                   Author :           Date :              2504