Text preview - extract from the document
13-2
                                               INTAKE      -   INTAKE AIR CONTROL SYSTEM
                                                                                                           1306U-01


INSPECTION



                                               1.    INSPECT INTAKE AIR CONTROL VALVE ASSY NO.2
                                               (a)   With 26.7 kPa (200 mm Hg, 7.9 in. Hg) of vacuum applied
                                                     to the actuator, check that the actuator rod moves.
                                               (b)   One minute after applying the vacuum, check that the ac-
                                                     tuator rod does not return.
                                               (c)   If the operation is not as specified, replace the intake air
                                                     control valve assembly No.2.

                                      A82243



                                               2.    INSPECT INTAKE AIR CONTROL VALVE ASSY NO.3
                                               (a)   Inspect actuator operation
                                                     (1) With 26.7 kPa (200 mm Hg, 7.9 in. Hg) of vacuum
                                                          applied to the actuator, check that the actuator rod
                                                          moves.
                                                     (2) One minute after applying the vacuum, check that
                                                          the actuator rod does not return.
                                                     (3) If the operation is not as specified, replace the in-
                                      A75330              take air control valve No.3.

                               Ohmmeter        (b)    Inspect VSV operation
                                                      (1) Using an ohmmeter, check the resistance between
                                                            the terminals.
                                                      Resistance: 37 to 44  at 20_C (68_F)
                                               If the resistance is not as specified, replace the VSV.




                      Resistance      A75331




                              Ohmmeter               (2)    Inspect the VSV for ground.
                                                             S    Using an ohmmeter, check that there is no
                                                                  continuity between each terminal and the
                                                                  body.
                                               If there is continuity, replace the VSV.




                    No Continuity     A75332




2005 SIENNA REPAIR MANUAL (RM1163U)

                                                                      Author :             Date :            2296
                                                                                                             13-3
                                                INTAKE   -   INTAKE AIR CONTROL SYSTEM

                                                      (3)    Inspect the VSV operation.
                        Filter                                S    Check that air flows from port E to the filter.




                 E
                                 Air

                                       A75333



                                                              S    Apply battery voltage across the terminals.
                                                              S    Check that air flows from port E to port F.
                                                If operation is not as specified, replace the VSV.

    F
             E           Air


                       Battery
                                       A75334



                                                3.    INSPECT AIR CLEANER CAP SUB-ASSY
                                                (a)   Cover port C with finger, and check that air flows from port
                                                      B to port A.
                 C                              (b)   Cover port C with finger, and check that air does not flow
                                                      from port A to port B.
                 A                              (c)   Cover port A and C with fingers, and apply 60 kPa (450
                 B                                    mm Hg, 18 in. Hg) of vacuum to port B, and check that
                                                      there is no change of vacuum after one minute.
                                       A51995




Ohmmeter         Resistance                     4.     INSPECT VACUUM SWITCHING VALVE ASSY NO.1
                                                (a)    Inspect the VSV for open circuit.
                                                       (1) Using an ohmmeter, check the resistance between
                                                             the terminals.
                                                       Resistance: 33 to 39  at 20_C (68_F)
                                                If the resistance is not as specified, replace the VSV.



                                       S04525




Ohmmeter                                        (b)    Inspect the VSV for ground.
             No Continuity
                                                       (1) Using an ohmmeter, check that there is no continu-
                                                             ity between each terminal and the body.
                                                If there is continuity, replace the VSV.




                                       S04524



2005 SIENNA REPAIR MANUAL (RM1163U)

                                                                   Author :              Date :              2297
13-4
                                               INTAKE   -   INTAKE AIR CONTROL SYSTEM


             Air
                                               (c)   Inspect the VSV operation.
                                                     (1) Check that air flows from port E to the filter.



                   E

                             Filter


                                      FI6393



                                                     (2) Apply battery voltage across the terminals.
       Air                                           (3) Check that air flows from port E to port F.
                                               If operation is not as specified, replace the VSV.


        E

  F
                                Battery
                                      S04523