65-4
                                               LIGHTING      -   LIGHTING SYSTEM
                                                                                                                                  650SA-01


INSPECTION



                                                1.   HEADLAMP DIMMER SWITCH ASSY
                                                (a)  Inspect light control switch continuity.
                                                     (1) Check that there is continuity between the terminals
                                                          at each switch position as shown in the chart.
                                                Standard:
                                                      Switch operation             Tester connection            Specified condition
                                                             OFF                             -                    No continuity
                                                             TAIL                         14 - 16                   Continuity
                                      E57951                HEAD                        13 - 16 - 14                Continuity
                                                            AUTO                          12 - 16                   Continuity
                                                (b)  Inspect headlight dimmer switch continuity.
                                                     (1) Check that there is continuity between the terminals
                                                          at each switch position as shown in the chart.
                                                Standard:
                                                      Switch operation             Tester connection            Specified condition
                                                           FLASH                         7 - 8 - 16                 Continuity
                                                         LOW BEAM                         16 - 17                   Continuity
                                                          HI BEAM                          7 - 16                   Continuity
                                                (c)  Inspect turn signal switch continuity.
                                                     (1) Check that there is continuity between the terminals
                                                          at each switch position as shown in the chart.
                                                Standard:
                                                      Switch operation             Tester connection            Specified condition
                                                          Right turn                       2-3                      Continuity
                                                           Neutral                           -                    No continuity
                                                           Left turn                       1-2                      Continuity
                                                (d)  Inspect front fog light switch continuity.
                                                     (1) Check that there is continuity between the terminals
                                                          at each switch position as shown in the chart.
                                                Standard:
                                                      Switch operation             Tester connection            Specified condition
                                                             OFF                             -                    No continuity
                                                              ON                          11 - 18                   Continuity




                                                2.   HAZARD WARNING SIGNAL SWITCH ASSY
                                                (a)  Check that there is continuity between the terminals at
                                                     each switch position as shown in the chart.
                                                Standard:
                                                      Switch operation             Tester connection            Specified condition
                                                             OFF                           3-4                    No continuity
                                                              ON                           3-4                      Continuity
                                                      Illumination circuit                 5-6                      Continuity

                                      I35767



2005 SIENNA REPAIR MANUAL (RM1163U)

                                                                             Author :                  Date :                       3087
                                                                                                                                    65-5
                                                LIGHTING      -   LIGHTING SYSTEM

                                                 (b)
                                                   Inspect illumination operation.
                                                   (1) Connect the positive (+) lead from the battery to the
                                                        terminal 6 and negative (-) lead to the terminal 5,
                                                        then check that the illumination comes on.
3.    FRONT DOOR COURTESY LAMP SWITCH ASSY
(a)   Check that there is continuity between the terminal and the switch body when the switch is operated.
      Standard:
      ON (When shaft is pressed): No continuity
      OFF (When shaft is not pressed): Continuity
4.    REAR DOOR COURTESY LAMP SWITCH ASSY
(a)   Check that there is continuity between the terminal and the switch body when the switch is operated.
      Standard:
      ON (When shaft is pressed): No continuity
      OFF (When shaft is not pressed): Continuity

                                                 5.       BACK DOOR LOCK ASSY (W/O POWER BACK DOOR)
                                                 (a)      Inspect back door courtesy lamp switch operation.
                                                          (1) Check that there is continuity between the terminal
                                                               5 and the terminal 6 when the back door is open and
                                                               closed.
                                                          Standard:
                                                          Back door is open: No continuity
                                                          Back door is closed: Continuity
                                       I35768



                                                 6.       BACK DOOR LOCK ASSY (W/ POWER BACK DOOR)
                                                 (a)      Inspect back door courtesy lamp switch operation.
                                                          (1) Check that there is continuity between the terminal
                                                               3 and the terminal 4 when the back door is open and
                                                               closed.
                                                          Standard:
                                                          Back door is open: No continuity
                                                          Back door is closed: Continuity
                                       I35768



                                                 7.   HEADLAMP RELAY
                                                 (a) Inspect relay continuity.
                                                 Standard:
                                                            Condition                Tester connection            Specified condition
                                                             Always                        1-2                        Continuity
                                                             Always                        3-5                      No continuity
                                                        Apply B+ between
                                                                                           3-5                        Continuity
                                                       the terminal 1 and 2

                                       E64835




 2005 SIENNA REPAIR MANUAL (RM1163U)

                                                                              Author :                   Date :                     3088
65-6
                                                   LIGHTING     -   LIGHTING SYSTEM

                                                    8.   TAIL LAMP RELAY
                                                    (a) Inspect relay continuity.
                                3                   Standard:
                                                              Condition             Tester connection            Specified condition
                                5
                                                                                          1-2
                                                               Always                                                Continuity
                                                                                          3-4
                            2   4     1                        Always                     3-5                      No continuity
                                                        Apply B+ between
                                                                                          3-5                        Continuity
                                                       the terminal 1 and 2
                                          E68810



                                                    9.   FOG LAMP RELAY
                                                    (a) Inspect relay continuity.
                                                    Standard:
                                                              Condition             Tester connection            Specified condition
                                                               Always                     1-2                        Continuity
                                                               Always                     3-5                      No continuity
                                                        Apply B+ between
                                                                                          3-5                        Continuity
                                                       the terminal 1 and 2

                                          B16200



                                                    10. RUNNING LIGHT RELAY
                                                    (a) Inspect relay continuity.
                                3                   Standard:
                                                              Condition             Tester connection            Specified condition
                                5
                                                                                          1-2
                                                               Always                                                Continuity
                                                                                          3-4
                            2   4     1                        Always                     3-5                      No continuity
                                                        Apply B+ between
                                                                                          3-5                        Continuity
                                                       the terminal 1 and 2
                                          E68810



                                                    11. HEADLAMP DAY DIM LIGHT RELAY
                                                    (a) Inspect relay continuity.
                                                    Standard:
                                                              Condition             Tester connection            Specified condition
                                                               Always                     1-2                        Continuity
                                                               Always                     3-5                      No continuity
                                                        Apply B+ between
                                                                                          3-5                        Continuity
                                                       the terminal 1 and 2

                                          B16200



                                                    12. BRK RELAY
                                                    (a) Inspect relay continuity.
                                                    Standard:
                                                              Condition             Tester connection            Specified condition
                                                                                          1-2
                                                               Always                                                Continuity
                                                                                          3-4
                                4
                                                               Always                     3-5                      No continuity
                                                        Apply B+ between
                                                                                          3-5                        Continuity
                                                       the terminal 1 and 2
                                          E67351



2005 SIENNA REPAIR MANUAL (RM1163U)

                                                                              Author :                  Date :                     3089
                                                                                                                               65-7
                                               LIGHTING    -    LIGHTING SYSTEM

                                                13.    KEY CYLINDER LAMP ASSY
                                                (a)    Connect the battery positive (+) lead to the terminal 1 and
                                                       the battery negative (-) lead to the terminal 2, and check
                                                       that the indicator light comes on.




                                      I35769



                                                14.    TRANSPONDER KEY AMPLIFIER
                                                (a)    Inspect key cylinder lamp operation.
                                                       (1) Connect the battery positive (+) lead to the terminal
                                                            2 and the battery negative (-) lead to the terminal
                                                            6, and check that the indicator light comes on.




                                      E66577



                                                15.  ROOF CONSOLE BOX ASSY
                                                (a)  Inspect map light assy continuity.
                                                     (1) Check the continuity between the terminals at each
                                                          switch position as shown in the chart.
                                                Standard:
                                                      Switch operation          Tester connection            Specified condition
                                                           OFF                         -                       No continuity
                                                          DOOR                        2-3                        Continuity
                                      I35770                   ON                     1-2                        Continuity


                                                16.  AIR OUTLET REGISTER ASSY NO.1
                                                (a)  Inspect interior light LH No.1 continuity.
                                                     (1) Check that there is continuity between the terminals
                                                          at each switch position as shown in the chart.
                                                Standard:
                                                      Switch operation          Tester connection            Specified condition
                                                           OFF                         -                       No continuity
                                                          DOOR                        2-3                        Continuity
                                      I35770                   ON                     1-2                        Continuity


                                                17.  AIR OUTLET REGISTER ASSY NO.2
                                                (a)  Inspect interior light RH No.1 continuity.
                                                     (1) Check that there is continuity between the terminals
                                                          at each switch position as shown in the chart.
                                                Standard:
                                                      Switch operation          Tester connection            Specified condition
                                                           OFF                         -                       No continuity
                                                          DOOR                        2-3                        Continuity
                                      I35770                   ON                     1-2                        Continuity


2005 SIENNA REPAIR MANUAL (RM1163U)

                                                                         Author :                   Date :                     3090
65-8
                                               LIGHTING    -   LIGHTING SYSTEM

                                                18.  AIR DUCT REGISTER ASSY NO.3
                                                (a)  Inspect interior light LH No.2 continuity.
                                                     (1) Check that there is continuity between the terminals
                                                          at each switch position as shown in the chart.
                                                Standard:
                                                      Switch operation         Tester connection            Specified condition
                                                           OFF                        -                       No continuity
                                                          DOOR                       2-3                        Continuity
                                      I35770                ON                       1-2                        Continuity


                                                19.  AIR OUTLET REGISTER ASSY NO.4
                                                (a)  Inspect interior light RH No.2 continuity.
                                                     (1) Check that there is continuity between the terminals
                                                          at each switch position as shown in the chart.
                                                Standard:
                                                      Switch operation         Tester connection            Specified condition
                                                           OFF                        -                       No continuity
                                                          DOOR                       2-3                        Continuity
                                      I35770                ON                       1-2                        Continuity


20.    FRONT DOOR TRIM BOARD SUB-ASSY LH
(a)    Inspect front door courtesy lamp.
       (1) Check that the continuity exists between the terminals.
       Standard: There is continuity
21.    FRONT DOOR TRIM BOARD SUB-ASSY RH
(a)    Inspect front door courtesy lamp.
       (1) Check that the continuity exists between the terminals.
       Standard: There is continuity
22.    REAR DOOR COURTESY LAMP ASSY LH
(a)    Check that the continuity exists between the terminals.
       Standard: There is continuity
23.    REAR DOOR COURTESY LAMP ASSY RH
(a)    Check that the continuity exists between the terminals.
       Standard: There is continuity
24.    ROOM LAMP ASSY NO.2
(a)    Check that the continuity exists between the terminals.
       Standard: There is continuity
25.    LH VISOR ASSY
(a)    Inspect vanity light continuity.
       (1) Check that the continuity exists between the terminal 1 and the terminal 2 when the light is oper-
            ated.
       Standard:
       OFF (closed): No continuity
       ON (opened): Continuity




2005 SIENNA REPAIR MANUAL (RM1163U)

                                                                         Author :                  Date :                     3091
                                                                                                                                             65-9
                                                       LIGHTING      -    LIGHTING SYSTEM

26.   RH VISOR ASSY
(a)   Inspect vanity light continuity.
      (1) Check that the continuity exists between the terminal 1 and the terminal 2 when the light is oper-
           ated.
      Standard:
      OFF (closed): No continuity
      ON (opened): Continuity




                      2               1                 27.  HEADLAMP LEVELING SWITCH
                                                        (a)  Connect the battery positive (+) lead to the terminal 1 and
                                                             the battery negative (-) lead to the terminal 5.
                                                        (b) Measure the resistance between the terminal 4 and the
                                                             battery negative (-) lead when headlamp leveling switch
                                                             is operated.
                                                        (c) Measure the resistance between the terminal 5 and the
                                  4
                      5                                      battery negative (-) lead when headlamp leveling switch
                                                             is operated.
                                                        Standard:
                          V
                                                                         Switch position                        Specified voltage (V)
                                                                               0                                     9.0 to 12.6
                                                                               1                                     7.9 to 11.1
                                                                               2                                        6.9 to 9.6
                                                                               3                                        5.8 to 8.2
                                                                               4                                        4.7 to 6.6
                                                                               5                                        3.7 to 5.1



                                              E66581



                                                        (d)      Inspect switch illumination.
                                                                 (1) Connect the battery positive (+) lead to the terminal
                                                                      3 and the battery negative (-) lead to the terminal
                                                                      6, and check that the illumination comes on.

                  6                       3



                                              E66582



                                                        28.  STOP LAMP SWITCH ASSY
                              4                3        (a)  Check the continuity between the terminals at each
                                                             switch position as shown in the chart.
                                                        Standard:
                                                                Switch position            Tester connection              Specified condition
                                                                Switch pin free                  1-2                         No continuity
                              1                  2
                                                                Switch pin free                  3-4                           Continuity
 Free Pushed in                                               Switch pin pushed in               1-2                           Continuity

                                              E65594
                                                              Switch pin pushed in               3-4                         No continuity


2005 SIENNA REPAIR MANUAL (RM1163U)

                                                                                   Author :                    Date :                        3092
65-10
                                               LIGHTING      -   LIGHTING SYSTEM

                                                29.  INTERIOR DOME LAMP SWITCH ASSY
                                                (a)  Check that there is continuity between the terminals at
                                                     each switch position as shown in the chart.
                                                Standard:
                                                       Switch operation            Tester connection              Specified condition
                                                                                           8-7
                                                             OFF                           9-7                      No continuity
                                                                                           10 - 7
                                                                                           5 - 10
                                      I35771                DOOR                           6-9                        Continuity
                                                                                           7-8
                                                              ON                        7 - 8 - 9 - 10                Continuity
                                                (b)      Inspect illumination operation.
                                                         (1) Connect the battery positive (+) lead to the terminal
                                                              4 and the battery negative (-) lead to the terminal
                                                              1, and check that the illumination comes on.




                                                30. LIGHT CONTROL RELAY
                                                (a) Inspect relay continuity.
                                                Standard:
                                                           Condition               Tester connection              Specified condition
                                                            Always                          1-2                       Continuity
                                                            Always                          3-5                     No continuity
                                                       Apply B+ between
                                                                                            3-5                       Continuity
                                                      the terminal 1 and 2

                                      B16200