Service Manuals, User Guides, Schematic Diagrams or docs for : . Car Manuals Toyota Sienna 2004-2007 Approved SRM 04 70 20w7a20a reset400
<< Back |
HomeMost service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download
Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing.
If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.
Image preview - the first page of the document
>> Download reset400 documenatation <<Text preview - extract from the document70-12 WINDSHIELD/WINDOWGLASS/MIRROR - POWER WINDOW CONTROL SYSTEM (W/ JAM
PROTECTION)
700S4-01
RESET
NOTICE:
S Resetting the driver's power window motor (initializing the pulse sensor) is necessary when
the battery terminal is disconnected; when the master switch, wire harness, power window reg-
ulator and power window motor are replaced or removed/installed; or when the fuses are re-
placed. AUTO operation function, jam protection function and remote operation function via the
power window master switch do not operate without resetting.
S If the AUTO switch (driver side switch) of the master switch has been continuously operated
for a long time, the power window motor will stop so that no additional load can be applied to
the motor. Continuing to operate the switch even after the motor has stopped will cause the
switch to blink while restricting the AUTO UP/DOWN function and the remote UP/DOWN func-
tion. If this happens, reset the motor again after several minutes have passed.
S Whenever disconnecting the battery terminal, reset all the other systems besides the power
window control system.
1. RESET POWER WINDOW REGULATOR MOTOR (DRIVER SIDE)
(a) Turn the ignition switch ON.
(b) Halfway open the power window by pressing the master switch.
(c) Fully pull up the master switch until the power window is fully closed and continue to hold the switch
for approx. 1 second after the power window is fully closed.
(d) Check that the AUTO UP/DOWN function operates normally.
If operation is normal, reset operations have been completed at this time. If not normal, follow steps (e) to
(g) below.
(e) Disconnect the negative battery terminal for 10 seconds.
(f) Connect the battery terminal.
(g) Perform the above steps (a) to (d) again.
If operation is normal, reset operations have been completed at this time. If not normal, follow steps (h) to
(k) below.
(h) Turn the ignition switch ON.
(i) Halfway open the power window by pressing the master switch.
(j) Fully pull up the master switch until the power window is fully closed and continue to hold the switch
for approx. 12 seconds after the power window is fully closed.
(k) Check that the AUTO UP/DOWN function operates normally.
2005 SIENNA REPAIR MANUAL (RM1163U)