Service Manuals, User Guides, Schematic Diagrams or docs for : . Car Manuals Toyota Sienna 2004-2007 Approved SRM 04 73 20mtr x140001

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
x140001


>> Download x140001 documenatation <<

Text preview - extract from the document
                                                                                              73-23
                       THEFT DETERRENT & DOOR LOCK   -   ENGINE IMMOBILIZER SYSTEM


ENGINE IMMOBILIZER SYSTEM
                                                                                              730EO-09


REGISTRATION
1.    DESCRIPTION OF CODE REGISTRATION
(a)   When adding master keys and sub-keys (Additional registration).
      (1) Register the key code (immobiliser code) in the transponder key ECU.
                         Target ECU                                             See Step
                     Transponder key ECU                                             3.
(b)   When replacing the transponder key ECU (New registration).
      (1) Register the key code (immobiliser code) in the transponder key ECU.
                         Target ECU                                             See Step
                     Transponder key ECU                                             2.
      (2)   Register the ECU COMMUNICATION ID between the ECM and the transponder key ECU.
                         Target ECU                                             See Step
                            ECM                                                      5.
(c)   When replacing the ECM.
      (1) Register the ECU COMMUNICATION ID between the ECM and the transponder key ECU.
                         Target ECU                                             See Step
                     Transponder key ECU                                             5.




 2005 SIENNA REPAIR MANUAL (RM1163U)

                                                               Author :              Date :   3331
73-24
                      THEFT DETERRENT & DOOR LOCK         -    ENGINE IMMOBILIZER SYSTEM

2.    KEY REGISTRATION IN AUTOMATIC REGISTRATION (NEW REGISTRATION)
(a) The new registration of the key codes (immobiliser codes) is made automatically.
HINT:
 S    When you install a new transponder key ECU, the key codes (immobiliser codes) must be registered.
 S    A new transponder key ECU starts in the automatic key code registration mode. In this mode, a maxi-
      mum of 4 key codes for 3 master keys and 1 sub-key can be registered. Since the transponder key
      ECU can distinguish types of keys, the registration order is not specified.


 Automatic Key Code Registration                                                                      Security Indicator
 (New Registration)
                                                   START


                                                                                                      BLINKING
                                                                                                      (Until the first key is
                                                                                                      inserted.)



                                Insert the key in the ignition key cylinder.




                                                                                                      OFF
                                                                                                      (Approx. 1 sec.)
                                              Registration begins.
                      (The registration is completed approx. 1 sec. after the key is inserted.)




                                               Remove the key.
                                                                                                      ON
                                                                                                      (When the maximum
                                                                                                      number of key codes
                                                                                                      are registered, the
                                                                                                      security indicator re-
                        Yes                                                                           mains OFF until the
                                          Register another key?                                       last key registered is
                                                                                                      removed. After it is
                                                                                                      removed, the securi-
                                                                                                      ty indicator starts
                                                          No                                          blinking.)


                                                    END




2005 SIENNA REPAIR MANUAL (RM1163U)

                                                                      Author :               Date :                     3332
                                                                                                    73-25
                         THEFT DETERRENT & DOOR LOCK     -    ENGINE IMMOBILIZER SYSTEM

HINT:
S     When no key is inserted in the ignition key cylinder in the automatic key code registration mode, the
      security indicator remains on.
 S    When the immobiliser system is operating normally and the key is pulled out, the security indicator
      blinks.
NOTICE:
If the key code registration has failed in the automatic key code registration mode, code 2-1 will be
output from the security indicator. Trying to re-register an already registered key will cause code
2-2 to be output when the key is inserted. The output details are shown below.
    Security Indicator
                                             0.2 sec.

                                       ON
                         Normal
             (Immobiliser system is
                                       OFF
             operating normally.)
                                                   1.8 sec.



                                             0.25 sec.        1 sec.

                                       ON
                         Code 2-1
                                       OFF

                                              0.25 sec.
                                                      0.5 sec.



                                             0.25 sec.            1 sec.

                                      ON
                         Code 2-2
                                      OFF


                                               0.25 sec.
                                                       0.5 sec.




(b)     Finish the automatic key code registration mode.
        The automatic key code registration mode can be forced to end when at least 1 key code (immobiliser
        code) for the master key has been registered.
        (1) Turn the ignition switch ON/OFF alternately 5 times within 10 seconds using the already regis-
              tered master key.




 2005 SIENNA REPAIR MANUAL (RM1163U)

                                                                    Author :              Date :     3333
73-26
                        THEFT DETERRENT & DOOR LOCK    -   ENGINE IMMOBILIZER SYSTEM

3.    REGISTRATION OF ADDITIONAL KEY (ADDITIONAL REGISTRATION)
(a) Register an additional key by using the hand-held tester.
HINT:
 S    A maximum of 5 master key codes and 3 sub-key codes can be registered.
 S    Registration mode will end if each step is not completed within the specified time.
 S    When the ignition cylinder or the key cylinder set is replaced, remove the transmitter module from the
      original master key. Then install this transmitter module to a new key and use it as master key. If neces-
      sary, use this master key to register other keys.




 2005 SIENNA REPAIR MANUAL (RM1163U)

                                                                  Author :             Date :              3334
                                                                                                                     73-27
                              THEFT DETERRENT & DOOR LOCK       -   ENGINE IMMOBILIZER SYSTEM



 Additional Registration



         Security Indicator

                                                      START
    BLINKING
    (Until the first
    key is inserted.)



                        Insert the already registered master key in the ignition key cylinder and
                        turn the ignition switch ON.

        OFF

                        Hand-held tester operation:
                            1. Select SIENNA from the menu.
                            2. Select IMMOBILISER.                                                       Within 120 sec.
                            3. Select ID UTILITY.
                            4. Select TRANSP CODE REG.
                         After the above operation, proceed to the next step according to the
                         prompts on the tester screen.
        ON                                                                                               Within 20 sec.
                                                                                                         after the tester
                        Remove the master key.                                                           instruction



                                                                                                         Within 10 sec.
                        Insert the key to be registered in the ignition key cylinder.

        BLINKING

                        After 60 sec., the key is registered.
                        (The security indicator goes off.)
        OFF


                                                       END



HINT:
S     A brief outline of procedures for key code registration is shown on this page. For detailed information,
      please refer to the prompts on the screen of the hand-held tester.
 S    When the immobiliser system is operating normally and the key is pulled out, the security indicator
      blinks.
NOTICE:
If the key code registration has failed in the automatic key code registration mode, code 2-1 will be
output from the security indicator. Trying to re-register an already registered key will cause code
2-2 to be output when the key is inserted. The output details are shown in step 2 (New Registration).

 2005 SIENNA REPAIR MANUAL (RM1163U)

                                                                          Author :              Date :                3335
73-28
                           THEFT DETERRENT & DOOR LOCK       -   ENGINE IMMOBILIZER SYSTEM

4.    ERASURE OF KEY CODE
(a) Erase key codes by using the hand-held tester.
HINT:
 S    All key codes are erased except for the master key which is used for erasing the key codes.
      In order to use a key for which the code has been erased, it is necessary to register the key code again.
 S    Registration operation will be cancelled if each step is not completed within the specified time.

 Erasing Key Code




    Security Indicator
                                                     START
 BLINKING
 (Until the first
 key is inserted.)
                         Insert the already registered master key in the ignition key cylinder
                         and turn the ignition switch ON.

    OFF
                         Hand-held tester operation:
                          1. Select SIENNA from the menu.
                          2. Select IMMOBILISER.                                                          Within 120 sec.
                          3. Select ID UTILITY.
                          4. Select TRANSP CODE ERS.
                           After the above operation, proceed to the next step in accordance
                           with the prompts on the tester screen.

 ON for 1 sec.                                                                                            Within 10 sec.
 then OFF                                                                                                 after the tester
                         Remove the master key.                                                           indicates

    BLINKING

                                                       END




HINT:
S       A brief outline of procedures for key code registration is shown on this page. For detailed information,
        please refer to the prompts on the screen of the hand-held tester.
S       When the immobiliser system is operating normally and the key is pulled out, the security indicator
        blinks.




 2005 SIENNA REPAIR MANUAL (RM1163U)

                                                                        Author :                 Date :                 3336
                                                                                                73-29
                      THEFT DETERRENT & DOOR LOCK   -   ENGINE IMMOBILIZER SYSTEM

5.  ECU COMMUNICATION ID REGISTRATION
NOTICE:
 S  The ECU communication ID should be registered when the transponder key ECU and/or the
    ECM is replaced in order to match the ECM COMMUNICATION ID.
 S  The engine cannot be started unless the ECM COMMUNICATION ID matches.
(a) Register the ECU communication ID.
    (1) After the transponder key ECU and/or the ECM is replaced, turn the ignition switch ON (the en-
         gine is not running).
    (2) Short the TC and CG terminals of the DLC3 and leave it as is for 30 minutes.
    (3) Check that the engine starts.




2005 SIENNA REPAIR MANUAL (RM1163U)

                                                              Author :              Date :      3337



◦ Jabse Service Manual Search 2026 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo