Text preview - extract from the document
                                                                                                                19-19
                                   STARTING & CHARGING        -   GENERATOR ASSY
                                                                                                                190NB-01


REPLACEMENT



                                                      1.    REMOVE GENERATOR ASSY
                       (a)                            (a)   Remove the wire harness clamp.
                                                      (b)   Disconnect the generator connector.
                             (c)
                                                      (c)   Open the terminal cap and remove the nut and the gener-
                                                            ator wire.

                                       (b)


                                             A79746



                                                      (d)   Loosen bolts A and B.
                                                      (e)   Loosen bolt C to lessen the tension of the V belt No. 1.

        A




              B                    C
                                             A81657



                                                      (f)   Remove bolts A, B and the generator.


        A




              B
                                             A79747



                                                      2.    INSTALL GENERATOR ASSY
                                                      (a)   Temporarily install generator with bolts A and B.

        A




              B
                                             A79747




2005 SIENNA REPAIR MANUAL (RM1163U)

                                                                       Author :             Date :              2569
19-20
                                STARTING & CHARGING     -   GENERATOR ASSY

                                                (b)   Adjust the V belt No. 1 tension by tightening bolt C.
                                                      (See page 14-1 )
                                                (c)   Tighten bolts A and B.
           A                                          Torque:
                                                      58 Nm (592 kgfcm, 43 ftlbf) for bolt A
                                                      18 Nm (184 kgfcm, 13 ftlbf) for bolt B
                                                (d)   install the generator wire with the nut.
                                                      Torque: 9.8 Nm (100 kgfcm, 7 ftlbf)
               B               C
                                       (e)
                                       A81657         Connect the generator connector.
                                       (f)            Install the wire harness clamp.
3.      INSPECT DRIVE BELT (See page 14-1 )