19-14
                                   STARTING & CHARGING     -   CHARGING SYSTEM
                                                                                                               190N6-02


ON-VEHICLE INSPECTION
1.      CHECK BATTERY ELECTROLYTE LEVEL
(a)     Check the electrolyte quantity of each cell.
        (1) If the electrolyte is under the low level, replace the battery (or add distilled water if possible) and
            check the charging system.




                                                  2.    CHECK BATTERY SPECIFIC GRAVITY
                                                  (a)   Check the specific gravity of each cell.
                                                        Standard specific gravity: 1.25 to 1.29 at 20_C (68_F)
                                                  HINT:
                                                  If the specific gravity is less than specification, charge the bat-
                                                  tery.



                                         A01259



                                                  3.    CHECK BATTERY VOLTAGE
                                                  (a)   If it has not been 20 minutes since you drove the vehicle
                                                        or since the engine was stopped, turn the ignition switch
                                                        and the electrical system (headlight, blower motor, rear
                                                        defogger etc.) to the on position for 60 seconds. This will
                                                        remove the surface charge on the battery.
                                                  (b)   Turn off the ignition switch and the electrical systems.
                                                  (c)   Measure the battery voltage between the negative (-)
                                         A01260         and positive (+) terminals of the battery.
                                                        Standard voltage: 12.6 to 12.8 V at 20_C (68_F)
                                                  HINT:
                                                  If the voltage is less than specification, charge the battery.




                                                  (d) Check the indicator as shown in the illustration.
                                                  HINT:
         Blue        White       Red               S    Blue: OK
                                                   S    White: Charging Necessary
                                                   S    Red: Insufficient Water




                                         Z11580



4.      CHECK BATTERY TERMINALS, FUSIBLE LINK AND FUSES
(a)     Check that the battery terminals are not loosened or corroded.
(b)     Check the fusible links, high-current fuses and regular fuses for continuity.


 2005 SIENNA REPAIR MANUAL (RM1163U)

                                                                     Author :              Date :                2564
                                                                                                            19-15
                                STARTING & CHARGING       -   CHARGING SYSTEM

                                                5.      INSPECT DRIVE BELT
                                                (a)     Visually check the belt for excessive wear, frayed cords
                                                        etc.
                                                HINT:
                                                S       If any defect found, replace the drive belt.
                                                S       Cracks on the rib side of a belt are considered acceptable.
                                                        If the belt has chunks missing from the ribs, it should be
                                                        replaced.
                                       B00543



                                                (b) Check that it fits properly in the ribbed grooves.
                                                HINT:
                                                Check with your hand to confirm that the belt has not slipped out
                                                of the groove on the bottom of the pulley.




                                       B00540



6.     VISUALLY CHECK GENERATOR WIRING
(a) Check that the wiring is in good condition.
7.     LISTEN FOR ABNORMAL NOISES FROM GENERATOR
(a) Check that there is no abnormal noise from the generator while the engine is running.
8.     INSPECT CHARGE WARNING LIGHT CIRCUIT
(a) Turn the ignition switch ON. Check that the charge warning light comes on.
(b) Start the engine and check that the light goes off.
HINT:
If the light does not operate as specified, troubleshoot the charge warning light circuit.
                                              9.    INSPECT CHARGING CIRCUIT WITHOUT LOAD
                                              (a) If a battery or generator tester is available, connect the
                                                    tester to the charging circuit as per manufacturer's
                                                    instructions.


            Ammeter                             (b)     If a tester is not available, connect a voltmeter to the
                          Disconnect Wire               charging circuit as follows.
                          from Terminal B
                                                        (1) Disconnect to the wire from terminal B of the gener-
                                                              ator and connect it to the negative (-) lead of the
 Battery                                                      ammeter.
                                                        (2) Connect the positive (+) lead of the ammeter to ter-
                         Generator                            minal B of the generator.
           Voltmeter                                    (3) Connect the positive (+) lead of the voltmeter to ter-
                                       A75980                 minal B of the generator.
                                                        (4) Ground the negative (-) lead of the voltmeter.




 2005 SIENNA REPAIR MANUAL (RM1163U)

                                                                    Author :             Date :              2565
19-16
                                 STARTING & CHARGING   -   CHARGING SYSTEM

                                              (c)Check the charging circuit.
                                                 (1) Keep the engine speed at 2,000 rpm, check the
                                                       reading on the ammeter and voltmeter.
                                                 Standard amperage: 10 A or less
                                                 Standard voltage: 13.2 to 14.8 V
10.     INSPECT CHARGING CIRCUIT WITH LOAD
(a)     Keep the engine speed at 2,000 rpm, turn on the high beam headlights and turn the heater blower
        switch to the "HI" position.
(b)     Check the reading on the ammeter.
        Standard amperage: 30 A or more
HINT:
S       If the ammeter reading is less than standard amperage, repair the generator.
S       If the battery is fully charged, the indication will sometimes be less than standard amperage.




 2005 SIENNA REPAIR MANUAL (RM1163U)