Text preview - extract from the document
73-16
                         THEFT DETERRENT & DOOR LOCK      -   DOOR CONTROL TRANSMITTER
                                                                                                          730E9-02


REGISTRATION
HINT:
S       If replacing the door control transmitter or the door control receiver, register the recognition code.
S       The add mode is used to register new recognition codes while still retaining codes already registered.
        This mode is used when a new transmitter is added. If the number of registered codes exceeds 4, the
        previously registered codes will be erased in order, starting from the first registered code.
S       The rewrite mode is used to erase all the previously registered recognition codes in order to register
        all new recognition codes. This mode is used when the transmitter or the door control receiver is ex-
        changed for a new one.
S       The confirmation mode is used to confirm how many recognition codes have already been registered
        before an additional registration of the recognition codes.
S       The prohibition mode is used to erase all the registered codes and disables the wireless door lock func-
        tion. This mode is used when the transmitter is lost.
S       All the following registration procedures must be performed in order continuously.

1.      When using hand-held tester:
        REGISTER RECOGNITION CODE

     Flow Chart of Recognition Code Registration
                                                              START




                                The vehicle should be in the following condition.
                                F Ignition switch is turned ON.




                   1.   Select a mode according to display of hand-held tester.




                                                       Add Mode or
                                                       Rewrite Mode




                                           Number of registered codes is shown.




                                                    Continued on next page




 2005 SIENNA REPAIR MANUAL (RM1163U)

                                                                      Author :           Date :             3324
                                                                                                               73-17
                        THEFT DETERRENT & DOOR LOCK        -   DOOR CONTROL TRANSMITTER

                    Continued from previous page




                2. Press LOCK and UNLOCK switch on transmitter simultaneously for more than 1 sec.


          Within
          3 sec.

                3. Press the LOCK or UNLOCK switch for more than 1 sec.




   Within 30 sec.


                    Response to registration completion:
                     Body ECU automatically performs power door LOCK-UNLOCK operation to show which
                     mode has been selected.


                    LOCK-UNLOCK Occurs Once                    LOCK-UNLOCK Occurs Twice

                    Registration of recognition code has       Registration of recognition code has failed.
                    been completed.
                                       T1                                          T1   T1
                      LOCK                                        LOCK

                    UNLOCK                                     UNLOCK

                                                                                     T1: Approx. 1 sec.
                    HINT:
                    When LOCK-UNLOCK operation is performed twice, registration of recognition code has
                    failed. Perform registration procedures by beginning once again.


                                                                                 Within 40 sec.
                            Proceed to flow chart to finish         If other transmitter is to be registered.
                            registration.                            HINT:
                                                                     4 recognition codes can be registered at one
                                                                     time.


                Perform either of the following.
                   F Use hand-held tester to order completion.
                   F Disconnect hand-held tester.




               Registration of recognition codes (add mode and rewrite mode) is completed.


2005 SIENNA REPAIR MANUAL (RM1163U)

                                                                      Author :               Date :            3325
73-18
                             THEFT DETERRENT & DOOR LOCK        -    DOOR CONTROL TRANSMITTER

2.      When not using hand-held tester:
        REGISTER RECOGNITION CODE

     Flow Chart of Recognition Code Registration
                                                                    START




                                 The following conditions should be met.
                                 F No key in ignition key cylinder.
                                 F Driver side door is opened (Other doors are closed).
                                 F Driver side door is unlocked.




                                 1.     Insert key into ignition key cylinder, then pull it out.


           Within 5 sec.

                                  2.    Insert key into ignition key cylinder, then pull it out.




                                  3.    Close and open driver side door twice.




                                  4.    Insert key into ignition key cylinder, then pull it out.
           Within 40 sec.




                                  5.    Close and open driver side door twice.




                                   6.    Insert key into ignition switch and close all doors.




            Within 40 sec.
                                                        Continued on next page




 2005 SIENNA REPAIR MANUAL (RM1163U)

                                                                            Author :               Date :   3326
                                                                                                               73-19
                          THEFT DETERRENT & DOOR LOCK      -   DOOR CONTROL TRANSMITTER

                                                     Continued from previous page

                              Mode Selection:
                                7.    Turn ignition switch from LOCK to ON and back to LOCK at approximately
                                      1 second intervals according to the number of times shown below.

                                 Number of ON-LOCK operations of ignition switch:

                                     Add Mode
                                     ON-LOCK operation: 1 time                            T1: Approx. 1 sec.
                                                            T1

                                                ON
                                             LOCK

                                     Rewrite Mode
                                     ON-LOCK operation: 2 times
                                                            T1 T1
                                                ON

                                             LOCK


                                      Confirmation Mode
          Within 40 sec.
                                     ON-LOCK operation: 3 times
                                                               T1   T1
                                               ON

                                             LOCK

                                     Prohibition Mode
                                     ON-LOCK operation: 5 times
                                                            T1 T1
                                                ON

                                             LOCK

                                      If the number of the ON-LOCK operations of the ignition switch
                                      is 0, 4 or 6 or more, there will be no response (power door lock and
                                      unlock operation) to show which mode has been selected.




                                 8.     Remove key from ignition key cylinder.



          Within 3 sec.
                                                        Continued on next page



2005 SIENNA REPAIR MANUAL (RM1163U)

                                                                     Author :             Date :               3327
73-20
                      THEFT DETERRENT & DOOR LOCK    -     DOOR CONTROL TRANSMITTER

                                                Continued from previous page

        Within
        3 sec.
                   Response to selected mode (Power door lock operation):

                    Body ECU automatically performs power door LOCK-UNLOCK operations to inform which
                    mode has been selected.
                      Add Mode
                        LOCK-UNLOCK operation: 1 time
                                                                                T1: Approx. 1 sec.
                                           T1
                                                                                T2: Approx. 2 sec.
                            LOCK

                         UNLOCK
                      Rewrite Mode
                         LOCK-UNLOCK operation: 2 times
                                        T1 T1
                            LOCK

                         UNLOCK

                       Confirmation Mode
                         LOCK-UNLOCK operation: The number of registered codes (1 - 5 times)
                                                1st time             2nd time
                                             T2          T2
                            LOCK

                         UNLOCK

                      Prohibition Mode
                        LOCK-UNLOCK operation: 5 times
                                       T1 T1
                            LOCK

                          UNLOCK
                       HINT:
                       F In the confirmation mode, when LOCK-UNLOCK operation is performed twice, the
                       number of registered recognition codes is 2.
                       F In the confirmation mode, when 0 codes are registered, LOCK-UNLOCK operation
                       is automatically performed 5 times.



                           Add Mode or                                Confirmation Mode and
        Within             Rewrite Mode                               Prohibition Mode
        40 sec.



                       Continued on next page                 Registration procedures are completed.


2005 SIENNA REPAIR MANUAL (RM1163U)

                                                                   Author :              Date :         3328
                                                                                                                     73-21
                        THEFT DETERRENT & DOOR LOCK     -    DOOR CONTROL TRANSMITTER


               Continued from previous page


    Within
    40 sec.
                9. Press LOCK and UNLOCK switches simultaneously on transmitter for more than 1 sec.


          Within
          3 sec.


               10. Press the LOCK or UNLOCK switch for more than 1 sec.


     Within
     3 sec.
               Response to registration completion:
               Body ECU automatically performs power door LOCK-UNLOCK operations to show
               whether registration has been completed correctly or not.


               LOCK-UNLOCK Occurs Once                      LOCK-UNLOCK Occurs Twice

               Registration of recognition code has     Registration of recognition code has failed.
               been completed.
                                    T1                                            T1   T1
                    LOCK                                     LOCK

               UNLOCK                                       UNLOCK

                                                                                    T1: Approx. 1 sec.
                   HINT:
                   If LOCK-UNLOCK operation is performed twice, registration of recognition code has
                   failed. Perform registration procedures by beginning once again.


                                                                                            Within 40 sec.
                              Proceed to flow chart to finish                   If another transmitter is to be registered.
                              registration.                                      HINT:
                                                                                 4 recognition codes can be registered
                                                                                 at once.


               Perform either of the following.
                 F Open a door.
                 F Insert key into ignition key cylinder.




                   Registration of recognition codes (add mode and rewrite mode) is completed.




2005 SIENNA REPAIR MANUAL (RM1163U)

                                                                     Author :                  Date :                 3329