C TROUBLESHOOTING
                        To Ignition SW            VOLTAGE CHECK
                        IG Terminal
                                                      (a) Establish conditions in which voltage is present at the check
                                                          point.
                                                          Example:
                        Fuse                                  [A] - Ignition SW on
                                                              [B] - Ignition SW and SW 1 on
                              [A]                             [C] - Ignition SW, SW 1 and Relay on (SW 2 off)
                                                      (b) Using a voltmeter, connect the negative lead to a good ground
                                                          point or negative battery terminal, and the positive lead to the
                       SW 1          Voltmeter            connector or component terminal.
                                                          This check can be done with a test light instead of a voltmeter.
                              [B]


                       Relay
                              [C]



 SW 2                  Solenoid




                                                  CONTINUITY AND RESISTANCE CHECK
                                                      (a) Disconnect the battery terminal or wire so there is no voltage
                                                          between the check points.
          Ohmmeter                                    (b) Contact the two leads of an ohmmeter to each of the check
                                                          points.




                SW

                                                          If the circuit has diodes, reverse the two leads and check
                                                          again.
                                                          When contacting the negative lead to the diode positive side
                                                          and the positive lead to the negative side, there should be
                                                          continuity.
     Ohmmeter                                             When contacting the two leads in reverse, there should be no
                                                          continuity.




      Diode

                                                      (c) Use a volt/ohmmeter with high impedance (10 k/V
                                                          minimum) for troubleshooting of the electrical circuit.
        Digital Type           Analog Type




12
                                                 2005 SIENNA (EWD613U)
                                                                                                             C
                 To Ignition SW           FINDING A SHORT CIRCUIT
                 IG Terminal
                                              (a) Remove the blown fuse and disconnect all loads of the fuse.
                                              (b) Connect a test light in place of the fuse.
                                              (c) Establish conditions in which the test light comes on.
   Test Light      Fuse Case                      Example:
                                                     [A] - Ignition SW on
                                                     [B] - Ignition SW and SW 1 on
                          Short [A]                  [C] - Ignition SW, SW 1 and Relay on (Connect the
                                                            Relay) and SW 2 off (or Disconnect SW 2)
                                              (d) Disconnect and reconnect the connectors while watching the
                  SW 1                            test light.
                                                  The short lies between the connector where the test light
                          Short [B]               stays lit and the connector where the light goes out.
Disconnect                                    (e) Find the exact location of the short by lightly shaking the
                      Disconnect                  problem wire along the body.

  Light           Relay                   CAUTION:
                                              (a) Do not open the cover or the case of the ECU unless
                                                  absolutely necessary. (If the IC terminals are touched,
                          Short [C]               the IC may be destroyed by static electricity.)
                                              (b) When replacing the internal mechanism (ECU part) of
                                                  the digital meter, be careful that no part of your body or
                      Disconnect                  clothing comes in contact with the terminals of leads
                                                  from the IC, etc. of the replacement part (spare part).
          SW 2    Solenoid




                                          DISCONNECTION OF MALE AND FEMALE
                                          CONNECTORS
                                                  To pull apart the connectors, pull on the connector itself, not
                                                  the wire harness.
                                                  HINT : Check to see what kind of connector you are
                                                         disconnecting before pulling apart.




                    Pull Up                                              Pull Up




                            Press Down                                       Press Down




                                                                                                              13
                                         2005 SIENNA (EWD613U)
C TROUBLESHOOTING
 Reference:                                              HOW TO REPLACE TERMINAL
                                                         (with terminal retainer or secondary locking device)
             10                                          1. PREPARE THE SPECIAL TOOL

                 3                               1            HINT : To remove the terminal from the connector, please
                                                                     construct and use the special tool or like object shown on
                                                                     the left.
                                                         2. DISCONNECT CONNECTOR
                         0.2
             1                                   (mm)


 Example:                                                3. DISENGAGE THE SECONDARY LOCKING DEVICE OR
                          Up              Tool
 (Case 1)                                                   TERMINAL RETAINER.

                                                             (a) Locking device must be disengaged before the terminal
                                                                 locking clip can be released and the terminal removed from
                                                                 the connector.
                                                             (b) Use a special tool or the terminal pick to unlock the secondary
                                                                 locking device or terminal retainer.
                                                             NOTICE:
                                                             Do not remove the terminal retainer from connector body.
     Terminal Retainer
                                                             [A]   For Non-Waterproof Type Connector
              Terminal Retainer                                    HINT : The needle insertion position varies according to the
                                                                          connector's shape (number of terminals etc.), so
                                                                          check the position before inserting it.

                                                                   "Case 1"
                                                                         Raise the terminal retainer up to the temporary lock
     [Retainer at Full Lock Position]                                    position.




                               Terminal
           Stopper             Retainer




     [Retainer at Temporary Lock Position]
                                                                   "Case 2"
                                                                         Open the secondary locking device.
  Example:                        Secondary
  (Case 2)                        Locking Device




14
                                                        2005 SIENNA (EWD613U)
                                                                                                                            C
                            Tool
                          Tab




                          Tab




Example:                                                                 [B]    For Waterproof Type Connector
                            Terminal
(Case 1)                                                 Tool
                            Retainer                                            HINT : Terminal retainer color is different
                                                                                       according to connector body.
                                                                                       Example:
                                                                                       Terminal Retainer   : Connector Body
                                                                                       Black or White      : Gray
                                                                                       Black or White      : Dark Gray
    Tool                  Access Hole
                                                                                       Gray or White       : Black
           [Male]          (   Mark)             [Female]

                                                                                "Case 1"
                                                                                      Type where terminal retainer is pulled
                                                                                      up to the temporary lock position (Pull
                                                                                      Type).
                                                                                       Insert the special tool into the terminal
                                                                                       retainer access hole (YMark) and pull
                                                                                       the terminal retainer up to the
                                                                                       temporary lock position.
                                                                                HINT : The needle insertion position varies
                     Retainer                                                          according to the connector's shape
                     at Full Lock Position                                             (Number of terminals etc.), so check
                                                                                       the position before inserting it.




            Retainer
            at Temporary Lock Position
            [Male]                           [Female]
                                                                                "Case 2"
                                                                                      Type which cannot be pulled as far as
Example:               Terminal Retainer                                              Power Lock insert the tool straight into
(Case 2)                                                                              the access hole of terminal retainer as
                                                                                      shown.




                              Tool                              Tool


                                                Press Down
     [Male]     Press Down                    [Female]

                                                                                                                             15
                                                        2005 SIENNA (EWD613U)
C TROUBLESHOOTING
                                            Push the terminal retainer down to the temporary lock position.




 Retainer at
 Full Lock Position




 Retainer at
 Temporary Lock Position
     [Male]                 [Female]


           Locking Lug                      (c) Release the locking lug from terminal and pull the terminal out
                                                from rear.



                           Tool




                                        4. INSTALL TERMINAL TO CONNECTOR

                                            (a) Insert the terminal.
                                            HINT:
                                            1. Make sure the terminal is positioned correctly.
                                            2. Insert the terminal until the locking lug locks firmly.
                                            3. Insert the terminal with terminal retainer in the temporary lock
                                                position.




                                           (b) Push the secondary locking device or terminal retainer in to
                                               the full lock position.
                                        5. CONNECT CONNECTOR