Text preview - extract from the document
AC-10
                                    AIR CONDITIONING     -   AIR CONDITIONING SYSTEM
                                                                                                         AC0C4-12


                                                 EVACUATING
Quick Disconnect                                 1.    CONNECT QUICK DISCONNECT ADAPTER TO
Adapter                                                CHARGING HOSES
                              Charging
                              Hose               2.    REMOVE CAPS FROM SERVICE VALVES ON RE-
                                                       FRIGERANT LINES
                                                 3.    SET MANIFOLD GAUGE SET
                        Service Valve            (a)   Close both valves of the manifold gauge set.
                                                 (b)   Connect the quick disconnect adapters to the service
                                        N13795
                                                       valves.




                                                 4.    EVACUATE AIR FROM REFRIGERATION SYSTEM
                                                 (a)   Connect the vacuum pump adapter to the vacuum pump.
 Vacuum Pump




          Vacuum Pump Adapter
                                        N13794



                                                 (b)   Connect the center hose of the manifold gauge set to the
                                                       vacuum pump adapter.
         Manifold                                (c)   Open both the high and low side valves and run the vacu-
         Gauge
                                                       um pump.
         Set
                                                 (d)   After 10 minutes or more, check that the low pressure
                                                       gauge indicates 750 mmHg (30 in. Hg) or more.
                                                 HINT:
                                                 If the reading is 750 mmHg (30 in. Hg) or more, close both
  Low Pressure                                   valves of the manifold gauge set and stop the vacuum pump.
  Service Valve
                                                 Check the system for leaks and repair if necessary.
                                                 (e) Close both the high and low side valves and stop the vac-
                                                       uum pump.
                                                 (f)   Leave the system in this condition for 5 minutes or more
                                                       and check that there is no change in gauge indication.
        High Pressure
        Service Valve


           Vacuum Pump Adapter
                                        N13791