>> Download seton documenatation <<Text preview - extract from the documentAC-20
AIR CONDITIONING - MANIFOLD GAUGE SET
1GR-FE: MANIFOLD GAUGE SET AC3RQ-02
SET ON
Low Pressure 1. CONNECT CHARGE HOSE TO MANIFOLD GAUGE
Charging Hose SET
Tighten the nuts by hand.
CAUTION:
Do not connect the wrong hoses.
2. CONNECT QUICK DISCONNECT ADAPTERS TO
CHARGING HOSES
Tighten the nuts by hand.
3. CLOSE BOTH VALVES OF MANIFOLD GAUGE SET
4. REMOVE CAPS FROM SERVICE VALVES ON RE-
FRIGERANT LINE
High Pressure
Charging Hose
I28849
Access Cab, Standard Cab 2UZ-FE:
Low Pressure
Charging Hose
High Pressure
Charging Hose
I11119
AC-21
AIR CONDITIONING - MANIFOLD GAUGE SET
Double Cab 2UZ-FE:
Low Pressure
Charging Hose
High Pressure
Charging Hose
I27018
5. CONNECT QUICK DISCONNECT ADAPTERS TO SER-
VICE VALVES
HINT:
Push the quick disconnect adapter onto the service valve, then
Sleeve
slide. Slide the sleeve of the quick disconnect adapter down-
ward to lock it.