Image preview - the first page of the document
>> Download regpro documenatation <<Text preview - extract from the documentBE-154 BODY ELECTRICAL - WIRELESS DOOR LOCK CONTROL SYSTEM (Double
Cab)
BE2LN-01
REGISTRATION PROCEDURE
REGISTER RECOGNITION CODE
HINT:
S Register the recognition code when replacing the door control transmitter or the door control receiver.
S The add mode is used to register new recognition codes while still retaining codes already registered.
This mode is used when a new transmitter is added. If the number of registered codes exceeds 4, the
previously registered codes will be erased in order, starting from the first registered code.
S The rewrite mode is used to erase all the previously registered recognition codes in order to register
new recognition codes. This mode is used when the transmitter or the door control receiver is replaced
a new one.
S The confirmation mode is used to confirm how many recognition codes have already been registered
before an additional registration of a recognition codes.
S The prohibition mode is used to erase all the registered codes and disables the wireless door lock func-
tion. This mode is used when the transmitter is lost.
S All the following registration procedures must be performed in order continuously.
BODY ELECTRICAL - WIRELESS DOOR LOCK CONTROL SYSTEM (Double BE-155
Cab)
Flow Chart of Recognition Code Registration
START
Make sure that the following conditions are met.
D No key in ignition key cylinder.
D Driver side door is open (other doors are closed).
D Driver side door is unlocked.
1. Insert key into ignition key cylinder, then pull it out.
2. Press door lock control switch (for manual operation) 5 times to LOCK/UNLOCK at approx.
1 sec. interval.
1st time 2nd time 3rd time 4th time 5th time
Approx. Approx.
LOCK 1 sec. 1 sec.
Within OFF
40 sec.
UNLOCK
3. Close and open driver side door
4. Press door lock control switch again (for manual operation) 5 times to LOCK/UNLOCK at
approx. 1 sec. interval.
1st time 2nd time 3rd time 4th time 5th time
Approx. Approx.
LOCK 1 sec. 1 sec.
OFF
UNLOCK
Within
40 sec.
5. Insert key into ignition key cylinder.
Continued on next page
BE-156 BODY ELECTRICAL - WIRELESS DOOR LOCK CONTROL SYSTEM (Double
Cab)
Continued from previous page
Mode Selection:
6. Turn ignition switch from LOCK to ON and back to LOCK at approximately
1 second intervals according to the number of times shown below.
Number of ON-LOCK operations of ignition switch:
Add Mode
ON-LOCK operation: 1 time T1: Approx. 1 sec.
T1
ON
LOCK
Rewrite Mode
ON-LOCK operation: 2 times
T1 T1
ON
LOCK
Confirmation Mode
Within 40 sec.
ON-LOCK operation: 3 times
T1 T1
ON
LOCK
Prohibition Mode
ON-LOCK operation: 5 times
T1 T1
ON
LOCK
If the number of the ON-LOCK operations of the ignition switch
is 0, 4 or 6 or more, there will be no response (power door lock and
unlock operation) to show which mode has been selected.
7. Remove key from ignition key cylinder.
Within 3 sec.
Continued on next page
BODY ELECTRICAL - WIRELESS DOOR LOCK CONTROL SYSTEM (Double BE-157
Cab)
Continued from previous page
Within
3 sec.
Response to selected mode (Power door lock operation):
Body ECU automatically performs power door LOCK-UNLOCK operation to inform which
mode has been selected.
Add Mode
LOCK-UNLOCK operation: 1 time
T1: Approx. 1 sec.
T1
T2: Approx. 2 sec.
LOCK
UNLOCK
Rewrite Mode
LOCK-UNLOCK operation: 2 times
T1 T1
LOCK
UNLOCK
Confirmation Mode
LOCK-UNLOCK operation: The number of registered codes (1 - 5 times)
1st time 2nd time
T2 T2
LOCK
UNLOCK
Prohibition Mode
LOCK-UNLOCK operation: 5 times
T1 T1
LOCK
UNLOCK
HINT:
D In the confirmation mode, when LOCK-UNLOCK operation is performed twice, the
number of registered recognition codes is 2.
D In the confirmation mode, when 0 codes are registered, LOCK-UNLOCK operation
is automatically performed 5 times.
Add Mode or
Confirmation Mode and
Within Rewrite Mode
Prohibition Mode
40 sec.
Continued on next page Registration procedures are completed.
BE-158 BODY ELECTRICAL - WIRELESS DOOR LOCK CONTROL SYSTEM (Double
Cab)
Continued from previous page
Within
40 sec.
8. Press LOCK and UNLOCK switches on transmitter simultaneously within 1.5 sec.
Within
3 sec.
9. Press either switch for more than 1.5 sec.
Within
3 sec.
Response to registration completion:
Body ECU automatically performs power door LOCK-UNLOCK operation to show
whether registration has been completed correctly or not.
LOCK-UNLOCK Occurs Once LOCK-UNLOCK Occurs Twice
Registration of recognition code has Registration of recognition code has failed.
been completed.
T1 T1 T1
LOCK LOCK
UNLOCK UNLOCK
T1: Approx. 1 sec.
HINT:
If LOCK-UNLOCK operation is performed twice, registration of recognition code has
failed. Perform registration procedures by beginning once again.
Within 40 sec.
Proceed to flow chart to finish If other transmitter is to be registered.
registration. HINT:
4 recognition codes can be registered
at once.
Perform either of the following.
D Open a door.
D Insert key into ignition key cylinder.
Registration of recognition codes (add mode and rewrite mode) is completed.