Text preview - extract from the document
DI-1166             DIAGNOSTICS   -   AUTOMATIC TRANSMISSION (A750E/A750F for
                                      2UZ-FE)
                                                                                DIDWK-01




    DTC   P0710   Transmission Fluid Temperature Sensor "A"
                  Circuit


    DTC   P0712   Transmission Fluid Temperature Sensor "A"
                  Circuit Low Input


    DTC   P0713   Transmission Fluid Temperature Sensor "A"
                  Circuit High Input
                                                     DIAGNOSTICS        -   AUTOMATIC TRANSMISSION (A750E/A750F for                     DI-1167
                                                                            2UZ-FE)

CIRCUIT DESCRIPTION
                                                            The ATF (Automatic Transmission Fluid) temperature sensor
                                                            converts the fluid temperature into a resistance value which is
                                                            input into the ECM.
                                                            The ECM applies a voltage to the temperature sensor through
                                                            ECM terminal THO1.
                                                            The sensor resistance changes with the transmission fluid tem-
                            Acceptable                      perature. As the temperature becomes higher, the sensor resis-
                                                            tance decreases.
   Resistance




                                                            One terminal of the sensor is grounded so that the sensor resis-
                                                            tance decreases and the voltage goes down as the tempera-
                                                            ture becomes higher.
                                                            The ECM calculates the fluid temperature based on the voltage
                                                            signal.




                 Temp.
 A67628                                           D14156




   DTC No.                         DTC Detection Condition                                                  Trouble Area
                (a) and (b) are detected momentarily within 0.5 sec. when
                neither P0712 nor P0713 is detected (1-trip detection logic)
                (a) ATF temperature sensor No.1 resistance is less than 79 .
                                                                                    S Open or short in ATF temperature sensor No.1 circuit
                (b) ATF temperature sensor No.1 resistance is more than 156
     P0710                                                                          S Transmission wire (ATF temperature sensor No.1)
                    k.
                                                                                    S ECM
                HINT:
                Within 0.5 sec., the malfunction switches from (a) to (b) or from
                (b) to (a)
                                                                                    S Short in ATF temperature sensor No.1 circuit
                ATF temperature sensor No.1 resistance is less than 79  for
     P0712                                                                          S Transmission wire (ATF temperature sensor No.1)
                0.5 sec. or more (1-trip detection logic)
                                                                                    S ECM
                ATF temperature No.1 sensor resistance is more than 156 k           S Open in ATF temperature sensor No.1 circuit
     P0713      when 15 minutes or more have elapsed after the engine start         S Transmission wire (ATF temperature sensor No.1)
                DTC is detected for 0.5 sec. or more (1-trip detection logic)       S ECM


MONITOR DESCRIPTION
These DTCs indicate an open or short in the automatic transmission fluid (ATF) temperature sensor circuit.
The automatic transmission fluid (ATF) temperature sensor converts ATF temperature to an electrical resis-
tance value. Based on the resistance, the ECM determines the ATF temperature, and the ECM detects an
open or short in the ATF temperature circuit. If the resistance value of the ATF temperature is less than 79*1
or more than 156k*2, the ECM interprets this as a fault in the ATF sensor or wiring. The ECM will turn on
the MIL and store the DTC.
*1: 150_C (302_F) or more is indicated regardless of the actual ATF temperature.
*2: -40_C (-40_F) is indicated regardless of the actual ATF temperature.
HINT:
The ATF temperature can be checked on the OBD II scan tool or hand-held tester display.
DI-1168                                                DIAGNOSTICS     -   AUTOMATIC TRANSMISSION (A750E/A750F for
                                                                           2UZ-FE)

MONITOR STRATEGY
                                                     P0710           ATF temperature sensor/Range check (Fluttering)

           Related DTCs                              P0712           ATF temperature sensor/Range check (Low resistance)
                                                     P0713           ATF temperature sensor/Range check (High resistance)
  Required sensors/Components           ATF temperature sensor (TFT sensor)
      Frequency of operation            Continuous
              Duration                  0.5 sec.
           MIL operation                Immediate
       Sequence of operation            None


TYPICAL ENABLING CONDITIONS
                                                                                        Specification
                    Item
                    It
                                                                Minimum                                           Maximum
The monitor will run whenever these
                                                                                     See page DI-1128
DTCs are not present.

Range check (Fluttering, Low resistance)
The typical enabling condition is not avail-
                                                                                             -
able.
Range check (High resistance)
Time after engine start                                      15 min. or more                                          -


TYPICAL MALFUNCTION THRESHOLDS
                      Detection criteria                                                           Threshold
Range check (Fluttering)
                                                                                               Less than 79 
TFT (transmission fluid temperature) sensor resistance                                               or
                                                                                              More than 156 k
Range check (Low resistance)
TFT (transmission fluid temperature) sensor resistance                                           Less than 79 
Range check (High resistance)
TFT (transmission fluid temperature) sensor resistance                                        More than 156 k


COMPONENT OPERATING RANGE
                           Parameter                                                             Standard value
TFT (transmission fluid temperature) sensor                                    Atmospheric temperature to approx. 130