                                                        DIAGNOSTICS         -      AUTOMATIC TRANSMISSION (A750E/A750F for                    DI-1247
                                                                                   2UZ-FE)
                                                                                                                                                DIDX0-01




     DTC                      P2716               Pressure Control Solenoid "D" Electrical
                                                  (Shift Solenoid Valve SLT)

CIRCUIT DESCRIPTION
See page DI-1241
   DTC No.                              DTC Detection Condition                                                   Trouble Area
                                                                                        S Open or short in shift solenoid valve SLT circuit
                  Open or short is detected in shift solenoid valve SLT circuit for
    P2716                                                                               S Shift solenoid valve SLT
                  1 second or more while driving (1-trip detection logic).
                                                                                        S ECM


MONITOR DESCRIPTION
When an open or short in the linear solenoid valve (SLT) circuit is detected, the ECM interprets this as a fault.
The ECM will turn on the MIL and store the DTC.

MONITOR STRATEGY
            Related DTCs                              P2716                Shift solenoid valve SLT/Range check
  Required sensors/Components            Shift solenoid valve SLT
      Frequency of operation             Continuous
              Duration                   1 sec.
            MIL operation                Immediate
       Sequence of operation             None


TYPICAL ENABLING CONDITIONS
                                                                                              Specification
                     Item
                     It
                                                                     Minimum                                               Maximum
The monitor will run whenever this DTC is
                                                                                           See page DI-1128
not present.

Solenoid current cut status                                                                      Not cut
Battery voltage                                                     11 V or more                                               -
CPU command duty ratio to SLT                                       19% or more                                                -
Ignition switch                                                                                    ON
Starter                                                                                           OFF


TYPICAL MALFUNCTION THRESHOLDS
                       Detection criteria                                                                  Threshold
Solenoid status from IC                                                                             Fail (Open or short)


COMPONENT OPERATING RANGE
                            Parameter                                                                 Standard value
Output signal duty                                                                                    Less than 100%
DI-1248                                     DIAGNOSTICS     -   AUTOMATIC TRANSMISSION (A750E/A750F for
                                                                2UZ-FE)

WIRING DIAGRAM
          E1 Electronically Controlled
          Transmission Solenoid                                                                        ECM
                                                                                                      +B
                          SLT                                                                13
                                     G                              B-R
                                                                                             E6
                                      SLT+ 14                                                      SLT+



                                                                                             12
                            BR                                      G-W                         SLT-
                                                                                             E6
                                     SLT- 6




                                                                                                                    D14174


INSPECTION PROCEDURE

   1      Check transmission wire.

                  Transmission Wire Side:         PREPARATION:
                  (Connector Front View):         Disconnect the transmission wire connector.
                       SLT-                       CHECK:
   E1                                             Measure the resistance according to the value(s) in the table
                                                  below.
               8 7 6 5 4 3 2 1
                                                  OK:
               15 14 13 12 11 10 9
                                                                                              Specified Condition
                                                            Tester Connection
                                                                                                 20_C (68_F)
           SLT+                          D11994
                                                           14 (SLT+) - 6 (SLT-)                    5.0 to 5.6 
                                                  CHECK:
                                                  Measure the resistance according to the value(s) in the table
                                                  below.
                                                  OK:
                                                            Tester Connection                 Specified Condition
                                                         14 (SLT+) - Body ground                  10 k or higher
                                                          6 (SLT-) - Body ground                        


                                                    NG          Go to step 3.


  OK
                                       DIAGNOSTICS    -   AUTOMATIC TRANSMISSION (A750E/A750F for             DI-1249
                                                          2UZ-FE)



  2         Check harness and connector (Transmission wire - ECM)

ECM:                                         PREPARATION:
       E7     E6   E5     E4   E3            (a) Connect the transmission wire connector.
                                             (b) Disconnect the ECM connector.
                                             CHECK:
                                             Measure the resistance according to the value(s) in the table
                                             below.
                                             OK:
                                                                                        Specified Condition
      SLT+         SLT-                               Tester Connection
                                                                                           20_C (68_F)
                                    D14166
                                                E6 - 13 (SLT+) - E6 - 12 (SLT-)             5.0 to 5.6 
                                             CHECK:
                                             Measure the resistance according to the value(s) in the table
                                             below.
                                             OK:
                                                      Tester Connection                 Specified Condition
                                                 E6 - 13 (SLT+) - Body ground             10 k or higher
                                                 E6 - 12 (SLT-) - Body ground                   


                                               NG         Repair or replace the harness or connector
                                                          (See page IN-30).


 OK



Replace the ECM (See page SF-82).
DI-1250                             DIAGNOSTICS   -   AUTOMATIC TRANSMISSION (A750E/A750F for
                                                      2UZ-FE)



   3      Inspect shift solenoid valve SLT.

 Shift Solenoid Valve SLT:                PREPARATION:
                                          Remove the shift solenoid valve SLT (See page AT-12).
                                          CHECK:
                                          Measure the resistance according to the value(s) in the table
                                          below.
                                          OK:
                                                                                    Specified Condition
                                                   Tester Connection
                                                                                       20_C (68_F)
                                                         1-2                           5.0 to 5.6 
                                          CHECK:
             1           2                Connect the positive (+) lead with a 21 W bulb to terminal 2 and
                                          the negative (-) lead to terminal 1 of the solenoid valve connec-
                                          tor, then check the movement of the valve.
                                          OK:
                                                 The solenoid makes an operating sound.



                 (-)   (+)
                                 D11987
                                            NG        Replace the shift solenoid valve SLT
                                                      (See page AT-12).


  OK



 Repair or replace the transmission wire
 (See page AT-9).