DIAGNOSTICS - AUTOMATIC TRANSMISSION (A750E/A750F for DI-1247
2UZ-FE)
DIDX0-01
DTC P2716 Pressure Control Solenoid "D" Electrical
(Shift Solenoid Valve SLT)
CIRCUIT DESCRIPTION
See page DI-1241
DTC No. DTC Detection Condition Trouble Area
S Open or short in shift solenoid valve SLT circuit
Open or short is detected in shift solenoid valve SLT circuit for
P2716 S Shift solenoid valve SLT
1 second or more while driving (1-trip detection logic).
S ECM
MONITOR DESCRIPTION
When an open or short in the linear solenoid valve (SLT) circuit is detected, the ECM interprets this as a fault.
The ECM will turn on the MIL and store the DTC.
MONITOR STRATEGY
Related DTCs P2716 Shift solenoid valve SLT/Range check
Required sensors/Components Shift solenoid valve SLT
Frequency of operation Continuous
Duration 1 sec.
MIL operation Immediate
Sequence of operation None
TYPICAL ENABLING CONDITIONS
Specification
Item
It
Minimum Maximum
The monitor will run whenever this DTC is
See page DI-1128
not present.
Solenoid current cut status Not cut
Battery voltage 11 V or more -
CPU command duty ratio to SLT 19% or more -
Ignition switch ON
Starter OFF
TYPICAL MALFUNCTION THRESHOLDS
Detection criteria Threshold
Solenoid status from IC Fail (Open or short)
COMPONENT OPERATING RANGE
Parameter Standard value
Output signal duty Less than 100%
DI-1248 DIAGNOSTICS - AUTOMATIC TRANSMISSION (A750E/A750F for
2UZ-FE)
WIRING DIAGRAM
E1 Electronically Controlled
Transmission Solenoid ECM
+B
SLT 13
G B-R
E6
SLT+ 14 SLT+
12
BR G-W SLT-
E6
SLT- 6
D14174
INSPECTION PROCEDURE
1 Check transmission wire.
Transmission Wire Side: PREPARATION:
(Connector Front View): Disconnect the transmission wire connector.
SLT- CHECK:
E1 Measure the resistance according to the value(s) in the table
below.
8 7 6 5 4 3 2 1
OK:
15 14 13 12 11 10 9
Specified Condition
Tester Connection
20_C (68_F)
SLT+ D11994
14 (SLT+) - 6 (SLT-) 5.0 to 5.6
CHECK:
Measure the resistance according to the value(s) in the table
below.
OK:
Tester Connection Specified Condition
14 (SLT+) - Body ground 10 k or higher
6 (SLT-) - Body ground
NG Go to step 3.
OK
DIAGNOSTICS - AUTOMATIC TRANSMISSION (A750E/A750F for DI-1249
2UZ-FE)
2 Check harness and connector (Transmission wire - ECM)
ECM: PREPARATION:
E7 E6 E5 E4 E3 (a) Connect the transmission wire connector.
(b) Disconnect the ECM connector.
CHECK:
Measure the resistance according to the value(s) in the table
below.
OK:
Specified Condition
SLT+ SLT- Tester Connection
20_C (68_F)
D14166
E6 - 13 (SLT+) - E6 - 12 (SLT-) 5.0 to 5.6
CHECK:
Measure the resistance according to the value(s) in the table
below.
OK:
Tester Connection Specified Condition
E6 - 13 (SLT+) - Body ground 10 k or higher
E6 - 12 (SLT-) - Body ground
NG Repair or replace the harness or connector
(See page IN-30).
OK
Replace the ECM (See page SF-82).
DI-1250 DIAGNOSTICS - AUTOMATIC TRANSMISSION (A750E/A750F for
2UZ-FE)
3 Inspect shift solenoid valve SLT.
Shift Solenoid Valve SLT: PREPARATION:
Remove the shift solenoid valve SLT (See page AT-12).
CHECK:
Measure the resistance according to the value(s) in the table
below.
OK:
Specified Condition
Tester Connection
20_C (68_F)
1-2 5.0 to 5.6
CHECK:
1 2 Connect the positive (+) lead with a 21 W bulb to terminal 2 and
the negative (-) lead to terminal 1 of the solenoid valve connec-
tor, then check the movement of the valve.
OK:
The solenoid makes an operating sound.
(-) (+)
D11987
NG Replace the shift solenoid valve SLT
(See page AT-12).
OK
Repair or replace the transmission wire
(See page AT-9).