Service Manuals, User Guides, Schematic Diagrams or docs for : . Car Manuals Toyota Tundra 2000-2006 Approved 04-06 techinfo.toyota.com ileaf 06toyrm 06toypdf 06rmsrc 06tundra di ata750ef cip2740p

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
cip2740p


>> Download cip2740p documenatation <<

Text preview - extract from the document
                                                                                                                                   DI-1083
                                                DIAGNOSTICS        -     AUTOMATIC TRANSMISSION (A750E for 1GR-FE)
                                                                                                                                      DIDVQ-01




    DTC                   P2740           Transmission Fluid Temperature Sensor "B"
                                          Circuit


    DTC                   P2742           Transmission Fluid Temperature Sensor "B"
                                          Circuit Low Input


    DTC                   P2743           Transmission Fluid Temperature Sensor "B"
                                          Circuit High Input

CIRCUIT DESCRIPTION
ATF (Automatic Transmission Fluid) temperature sensor No.2 is on the transmission and just in front of the
oil cooler inlet pipeline.
If ECM detects the abnormally high temperature of ATF by this sensor, it draws driver's attention by illuminat-
ing the warning lamp.
HINT:
 S    The temperature of ATF easily rises when towing, climbing hills and in traffic, etc.
 S    If the ATF temperature sensor No.2 becomes short-circuited, the signal that indicates the ATF temper-
      ature is 150_C (302_F) or higher is input in ECM.
Vehicle conditions when the sensor is normal and when the sensor is short-circuited are indicated
in the table below.
  ATF temperature Sensor No.2
                                       Detection Condition                           Symptom                     Recovery Condition
            State
                                S AT fluid temp. more than 150_C       S AT Oil Temp. warning light re-   S AT fluid temp. less than 135_C
                                  (302_F).                               mains on                           (275_F). *2
                                S AT fluid temp. more than 130_C                                          S AT fluid temp. less than 110_C
                                                                       S Shift point too high.
                                  (266_F).                                                                  (230_F).
                                When the conditions (a) and (b)
       Sensor is normal
                                are satisfied.
                                                                                                          S AT fluid temp. less than 110_C
                                (a) AT fluid temp. more than 130_C
                                                                   S Lock-up at 3rd gear. *1                (230_F) *2 and engine coolant
                                    (266_F).
                                                                                                            temp. less than 95_C (203_F).
                                (b) Engine coolant temp. more
                                    than 95_C (203_F).
                                                                       S AT Oil Temp. warning light re-
                                S Any conditions.                        mains on                         S Symptoms still occur
    Sensor is short-circuited                                          S Shift point too high.
                                S Engine coolant temp. more than
                                                                       S Lock-up at 3rd gear. *1          S Symptoms still occur
                                  95_C (203_F).

HINT:
*1: When AT fluid temperature is normal, transmission locks up at 5th gear with the shift lever in D position
and at 4th gear with the shift lever in 4 position.
*2: When AT fluid temperature is in normal range, it decreases to less than 135_C (275_F) within 5 minutes
with the shift lever in P or N position in an idling state.
DI-1084
                                                       DIAGNOSTICS        -   AUTOMATIC TRANSMISSION (A750E for 1GR-FE)


   DTC No.                            DTC Detecting Condition                                                Trouble Area
                  (a) and (b) are detected momentarily within 0.5 sec. when
                  neither P2742 nor P2743 is detected (1-trip detection logic)
                  (a) ATF temperature sensor No.2 resistance is less than 25 
                      (0.046 V)                                                      S Open or short in ATF temperature sensor No.2 circuit
    P2740         (b) ATF temperature sensor No.2 resistance is more than 156        S Transmission wire (ATF temperature sensor No.2)
                      k (4.915 V)                                                    S ECM
                  HINT:
                  Within 0.5 sec. the malfunction switches from (a) to (b) or from
                  (b) to (a)
                                                                                     S Short in ATF temperature sensor No.2 circuit
                  ATF temperature sensor No.2 resistance is less than 25 
    P2742                                                                            S Transmission wire (ATF temperature sensor No.2)
                  (0.046 V) for 0.5 sec. or more (1-trip detection logic)
                                                                                     S ECM
                  ATF temperature No.2 sensor resistance is more than 156 k          S Open in ATF temperature sensor No.2 circuit
    P2743         (4.915 V) when 15 minutes or more after the engine start           S Transmission wire (ATF temperature sensor No.2)
                  DTC is detected for 0.5 sec. or more (1-trip detection logic)      S ECM


MONITOR DESCRIPTION
The Automatic Transmission Fluid (ATF) temperature sensor converts ATF temperature to an electrical re-
sistance value. Based on the resistance, the ECM determines the ATF temperature, and the ECM detects
an open or short in the AFT temperature circuit. If the resistance value of the ATF temperature is less than
25  (0.046 V) or more than 156 k (4.915 V), the ECM interprets this as a fault in the ATF sensor or wiring.
The ECM will turn on the MIL and store the DTC.

MONITOR STRATEGY
                                                     P2740               ATF temperature sensor/Range check (Fluttering)

            Related DTCs                             P2742               ATF temperature sensor/Range check (Low voltage)
                                                     P2743               ATF temperature sensor/Range check (High voltage)
  Required sensors/Components           ATF temperature sensor (TFT sensor)
      Frequency of operation            Continuous
              Duration                  0.5 sec.
            MIL operation               Immediate
       Sequence of operation            None


TYPICAL ENABLING CONDITIONS
                                                                                           Specification
                    Item
                    It
                                                                   Minimum                                            Maximum
The monitor will run whenever these
                                                                                        See page DI-963
DTCs are not present.

Range check (Fluttering, Low voltage)
The typical enabling condition is not avail-
                                                                                                -
able.

Range check (High voltage)
Time after engine start                                         15 min. or more                                           -
                                                                                                                            DI-1085
                                                      DIAGNOSTICS   -   AUTOMATIC TRANSMISSION (A750E for 1GR-FE)

TYPICAL MALFUNCTION THRESHOLDS
                     Detection criteria                                                     Threshold
Range check (Fluttering)
                                                                                        Less than 0.046 V
TFT (transmission fluid temperature) sensor voltage                                             or
                                                                                        More than 4.915 V
Range check (Low voltage)
TFT (transmission fluid temperature) sensor voltage                                     Less than 0.046 V
Range check (High voltage)
TFT (transmission fluid temperature) sensor voltage                                     More than 4.915 V


COMPONENT OPERATING RANGE
                        Parameter                                                        Standard value
TFT (transmission fluid temperature) sensor                              Atmospheric temperature to approx. 130



◦ Jabse Service Manual Search 2026 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo