DI-1079
DIAGNOSTICS - AUTOMATIC TRANSMISSION (A750E for 1GR-FE)
DIDVP-01
DTC P2716 Pressure Control Solenoid "D" Electrical
(Shift Solenoid Valve SLT)
CIRCUIT DESCRIPTION
See page DI-1073
DTC No. DTC Detection Condition Trouble Area
S Open or short in shift solenoid valve SLT circuit
Open or short is detected in shift solenoid valve SLT circuit for
P2716 S Shift solenoid valve SLT
1 second or more while driving (1-trip detection logic).
S ECM
MONITOR DESCRIPTION
When an open or short in the linear solenoid valve (SLT) circuit is detected, the ECM interprets this as a fault.
The ECM will turn on the MIL and store the DTC.
MONITOR STRATEGY
Related DTCs P2716 Shift solenoid valve SLT/Range check
Required sensors/Components Shift solenoid valve SLT
Frequency of operation Continuous
Duration 1 sec.
MIL operation Immediate
Sequence of operation None
TYPICAL ENABLING CONDITIONS
Specification
Item
It
Minimum Maximum
The monitor will run whenever this DTC is
See page DI-963
not present.
Case 1:
Battery voltage 10 V or more Less than 12 V
Ignition switch ON
CPU commanded duty - Less than 75%
Starter OFF
Case 2:
Battery voltage 12 V or more -
Ignition switch ON
Starter OFF
TYPICAL MALFUNCTION THRESHOLDS
Detection criteria Threshold
Case 1:
Output signal duty 100%
Case 2:
Output signal duty 100%
DI-1080
DIAGNOSTICS - AUTOMATIC TRANSMISSION (A750E for 1GR-FE)
COMPONENT OPERATING RANGE
Parameter Standard value
Output signal duty Less than 100%
WIRING DIAGRAM
E1 Electronically Controlled
Transmission Solenoid ECM
+B
SLT 13
G B-R
E6
SLT+ 14 SLT+
12
BR G-W SLT-
E6
SLT- 6
D14174
INSPECTION PROCEDURE
1 Check transmission wire.
Transmission Wire Side: PREPARATION:
(Connector Front View): Disconnect the transmission wire connector.
SLT- CHECK:
E1 Measure the resistance according to the value(s) in the table
below.
8 7 6 5 4 3 2 1
OK:
15 14 13 12 11 10 9
Specified Condition
Tester Connection
20_C (68_F)
SLT+ D11994
14 (SLT+) - 6 (SLT-) 5.0 to 5.6
CHECK:
Measure the resistance according to the value(s) in the table
below.
OK:
Tester Connection Specified Condition
14 (SLT+) - Body ground 10 k or higher
6 (SLT-) - Body ground
NG Go to step 3.
OK
DI-1081
DIAGNOSTICS - AUTOMATIC TRANSMISSION (A750E for 1GR-FE)
2 Check harness and connector (Transmission wire - ECM)
ECM: PREPARATION:
E7 E6 E5 E4 E3 (a) Connect the transmission wire connector.
(b) Disconnect the ECM connector.
CHECK:
Measure the resistance according to the value(s) in the table
below.
OK:
Specified Condition
SLT+ SLT- Tester Connection
20_C (68_F)
D14166
E6 - 13 (SLT+) - E6 - 12 (SLT-) 5.0 to 5.6
CHECK:
Measure the resistance according to the value(s) in the table
below.
OK:
Tester Connection Specified Condition
E6 - 13 (SLT+) - Body ground 10 k or higher
E6 - 12 (SLT-) - Body ground
NG Repair or replace harness or connector
(See page IN-30).
OK
Replace the ECM (See page SF-66).
DI-1082
DIAGNOSTICS - AUTOMATIC TRANSMISSION (A750E for 1GR-FE)
3 Inspect shift solenoid valve SLT.
Shift Solenoid Valve SLT: PREPARATION:
Remove the shift solenoid valve SLT (See page AT-12).
CHECK:
Measure the resistance according to the value(s) in the table
below.
OK:
Specified Condition
Tester Connection
20_C (68_F)
1-2 5.0 to 5.6
CHECK:
1 2 Connect the positive (+) lead with a 21 W bulb to terminal 2 and
the negative (-) lead to terminal 1 of the solenoid valve connec-
tor, then check the movement of the valve.
OK:
The solenoid makes an operating sound.
(-) (+)
D11987
NG Replace the shift solenoid valve SLT
(See page AT-12).
OK
Repair or replace the transmission wire
(See page AT-9).