Text preview - extract from the document
DI-404
                                         DIAGNOSTICS     -     ENGINE (1GR-FE)
                                                                                                             DIDUD-01




 Cranking Holding Function Control Circuit

CIRCUIT DESCRIPTION
The system detects the ignition switch's starting signal (STSW signal) and then supplies current to the starter
until the ECM judges that the engine has started successfully. The purpose is to reduce the holding time of
the ignition key.




                                   EFI                                           ACC CUT
                                                         STA Relay               Relay
                                                                                                  Ignition
    STSW
                                                                                                  SW
                                             AM2                                           ACC

     ACCR                                                                 Park/Neutral      ST2
                                                                          Position SW
                                                                   P
       NSW                                                         N                           STA
                                                                                    ACCR       NO. 2
                                                     Starter

  ENG rpm                                  Battery                                   ECM
                                                                          NSW              STSW
                                                                           STA


                                                                                                             A23466




WIRING DIAGRAM
Refer to DTC P0617 on page DI-276.

INSPECTION PROCEDURE

   1     Check operation of engine cranking.

CHECK:
When turning the ignition switch to the START position, check whether the starter motor starts.
OK:
    Engine is cranked.

                                                OK           Check for intermittent problems
                                                             (See page DI-11).


   NG
                                                                                                                        DI-405
                                               DIAGNOSTICS          -   ENGINE (1GR-FE)



   2      Connect hand-held tester, and check STA signal.

PREPARATION:
(a) Connect the hand-held tester to the DLC3.
(b) Turn the ignition switch to ON, and push the hand-held tester main switch ON.
(c) On the hand-held tester, enter the following menu: DIAGNOSIS / ENHANCED OBD II / DATA LIST
    / ALL / STARTER SIG.
CHECK:
Read the STA signal on the hand-held tester while the starter operates.
OK:
                                                Standard:
        Ignition Switch Position                               ON                                  START
            STARTER SIG                                      OFF                                     ON


                                                       NG               Repair or replace harness or connector.


  OK



   3      Check voltage between terminals STSW and STAR/NSW of ECM connector.

                                                     (a)       Measure the voltage between the terminals of the E6 and
                                                               E5 ECM connectors, while cranking the engine (ignition
            E6             E5                                  switch START position).
                                                               Standard:
                                                                Symbols (Terminal No.)            Specified condition
                                                                NSW (E6-8) - E1 (E5-1)                9 to 14 V
                                                               STSW (E5-12) - E1 (E5-1)               9 to 14 V
       NSW (+) STSW (+)            E1 (-)
                                            B17411



       Result:
            Terminal STAR                             Terminal STSW                               Proceed to
               9 to 14 V                                   9 to 14 V                                  A
                  0V                                       9 to 14 V                                  B
                  0V                                           0V                                     C


                                                           B            Replace ECM (See page SF-66).


                                                           C            Go to step 8.


   A
DI-406
                                   DIAGNOSTICS       -       ENGINE (1GR-FE)



   4     Check park/neutral position switch assembly.

 Component Side:
                                         (a)     Disconnect the park/neutral position switch connector.
                                         (b)     Check for resistance between each terminal shown below
                                                 when the shift lever is moved to each range.
                                                 Standard:
                                                  Shift range                  Terminal No.             Specified condition
                                                                                  1-3
                                                         P                                                    Below 1 
                                                                                  6-9
                                                         R                        2-3                         Below 1 
                                                                                  3-5
                                D14154                   N                                                    Below 1 
                                                                                  6-9
                                                         D                        3-7                         Below 1 
                                                         3                        3-4                         Below 1 
                                                     2, L                         3-8                         Below 1 


                                           NG            Check and repair harness and connector.


  OK



   5     Check starter relay.

                                         (a)     Remove the starter relay from the engine room R/B.
                                         (b)     Inspect the starter relay.
                                                 Standard:
                                               Terminal No.                             Specified condition
                                                  3-5                                    10 k or higher
                                                                                          Below 1 
                                                  3-5
                                                                           (Apply battery voltage terminals 1 and 2)



                                A19288
                                           NG            Replace starter relay.


  OK
                                                                                                                          DI-407
                                         DIAGNOSTICS       -   ENGINE (1GR-FE)



 6     Check harness and connector park/neutral position switch and starter relay.

Wire Harness Side
                                               (a)      Check the harness and the connector between the park/
                                                        neutral position switch connector and the starter relay.
  N1                                                    (1) Disconnect the park/neutral position switch con-
                                                             nector.
                                                        (2) Remove the starter relay from the engine room R/B.
                                                        (3) Check for resistance between the wire harness side
                                                             connectors.
                                                        Standard (Check for open):
 Park/Neutral position switch Connector
                                    A23563                          Symbols (Terminal No.)                     Specified condition
                                                     Park/Neutral position switch (N1-6) - Starter relay (1)       Below 1 

Engine Room R/B:                                        Standard (Check for short):
                                                                    Symbols (Terminal No.)                     Specified condition
                                               Park/Neutral position switch (N1-6) or Starter relay (1)
                                                                                                                10 k or higher
                                                                                               - Body ground

                                               (b)      Check the harness and the connector between the starter
                                                        relay and the body ground.
                      Starter Relay                     (1) Remove the starter relay from the engine room R/B.
                                                        (2) Check for resistance between the starter relay and
                                                              the body ground.
                                                        Standard (Check for open):
                                                                    Symbols (Terminal No.)                     Specified condition
                                                                Starter relay (2) - Body ground                    Below 1 




                                      A23461
                                                 NG            Repair or replace harness or connector.


 OK



 7     Check starter assembly (See page ST-12 (1.6 kw) or ST-24 (2.0 kw))


                                                 NG            Replace starter assembly.


 OK
DI-408
                                             DIAGNOSTICS     -   ENGINE (1GR-FE)



   8      Check STA fuse.

 Engine Room R/B                                  (a)     Remove the starter relay from the engine room R/B.
                                                  (b)     Measure the voltage between the terminal of the engine
                                                          room R/B and the body ground.
                                                          Standard:
                                                           Symbols (Terminal No.)                            Specified condition
                                                        Starter relay (5) - Body ground                          9 to 14 V


                                                    NG           Check for short in all harness and components
                            Starter Fuse A23469                  connected to STA fuse, and replace fuse.


  OK



   9      Check ignition switch.

                 ACC       AM1
                                                  (a)     Check for resistance between the connector terminals
       IG1                                                shown in the chart below.
                                       ST1                Standard:
                                                        Switch position                Terminal No.                 Specified condition
             4    3    2    1
                                                             LOCK                 All terminal to terminal           10 k or higher
    ST2      8    7    6    5                                ACC                           2-3                          Below 1 
                                                                                    2 - 3, 2 - 4, 3 - 4
                                                              ON                                                        Below 1 
                                                                                           6-7
                 AM2             IG2
                                                                                    1 - 2, 1 - 4, 2 - 4
                                         A23468             START                                                       Below 1 
                                                                                    6 - 7, 6 - 8, 7 - 8


                                                    NG           Replace ignition switch.


  OK



 Check and repair harness and connector.