                                                                                                                          DI-353
                                                DIAGNOSTICS     -     ENGINE (1GR-FE)
                                                                                                                             DIDUA-01




    DTC                  P043E            Evaporate Emission System Reference Ori-
                                          fice Clog Up


    DTC                  P043F            Evaporate Emission System Reference Ori-
                                          fice High Flow

CIRCUIT DESCRIPTION
Refer to the EVAP Inspection Procedure (see page DI-368).
                                                                                                            Detection   Detection
 DTC          Monitoring Item                  Detection Conditions                     Trouble Areas
                                                                                                             Timing      Logic
                                      One of following conditions are met:
                                      S 0.02 inch orifice low-flow
P043E   0.02 inch orifice clogged     S 0.02 inch orifice high-flow
                                                                               S Pump module                While
                                      S Vacuum pump ON stuck
                                                                               S Connector / Wire harness   ignition
                                      S Vacuum pump OFF stuck                                                           2 trips
                                                                                 (Pump module - ECM)        switch
                                      S Vent valve ON (Closed) stuck
                                                                               S ECM                        OFF
P043F   0.02 inch orifice high-flow    NOTE:
                                       P043E, P043F, P2401, P2402 and P2419
                                       have same DTC detection conditions.

WIRING DIAGRAM
Refer to the EVAP Inspection Procedure (see page DI-368).
DI-354
                                                   DIAGNOSTICS        -   ENGINE (1GR-FE)

MONITOR DESCRIPTION
5 hours after the ignition switch is turned to OFF, the electric vacuum pump creates negative pressure (vacu-
um) in the EVAP (Evaporative Emission) system. The ECM monitors for leaks and actuator malfunctions
based on the EVAP pressure.
HINT:
*: If the engine coolant temperature is not below 35_C (95_F) after 5 hours after the ignition switch is turned
off, the monitor check starts 2 hours later. If it is still not below 35_C (95_F) 7 hours after the ignition switch
is turned off, the monitor check starts 2.5 hours later.
 Sequence         Operations                                                Descriptions                                         Duration
    -       ECM activation         Activated by soak timer, 5 hours (7 or 9.5 hours) after ignition switch turned to OFF.            -
                                   Vent valve turned OFF (vent) and EVAP system pressure measured by ECM in order to
            Atmospheric pressure   register atmospheric pressure.
    A                                                                                                                           10 seconds
            measurement            If EVAP pressure does not reach between 70 kPa and 110 kPa (525 mmHg and 825 mmHg),
                                   ECM cancels EVAP system monitor.
                                   In order to determine 0.02 inch leak pressure standard, vacuum pump creates negative pres-
            0.02 inch leak pres-
    B                              sure (vacuum) through 0.02 inch orifice and then ECM checks if vacuum pump and vent          60 seconds
            sure measurement
                                   valve operate normally.
                                   Vent valve turned ON (closed) to shut EVAP system.
                                   Negative pressure (vacuum) created in EVAP system, and EVAP system pressure then
            EVAP system pres-
    C                              measured.                                                                                    15 minutes*
            sure measurement
                                   Write down the measured value as it will be used in the leak check.
                                   If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
                                   Purge VSV opened and then EVAP system pressure measured by ECM.
    D       Purge VSV monitor                                                                                                   10 seconds
                                   Large increase indicates normal.
                                   Leak check is performed after 0.02 inch reference pressure is measured.
            0.02 inch leak pres-
    E                              If stabilized system pressure higher than 0.02 inch leak pressure standard, ECM determines   60 seconds
            sure measurement
                                   that EVAP system leaking.
    F       Final check            Atmospheric pressure measured and then monitoring result recorded by ECM.                         -

* If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.
                                                                                                                         DI-355
                                                DIAGNOSTICS        -   ENGINE (1GR-FE)




  Operation A: Atmospheric Pressure Measurement                         Operation B: 0.02 Inch Leak Pressure Measurement

                            Canister
                                           Fuel Tank


                                   Vent Valve: OFF (vent)                                   OFF            OFF (vent)

 Purge VSV: OFF
 0.02 Inch Orifice
 Pressure Sensor
                                                  Air Filter                                   ON

 Vacuum Pump: OFF        Pump Module
               Operation C: EVAP Leak Check                                         Operation D: Purge VSV monitor



                      OFF          ON (closed)                                              ON             ON (closed)

                                                                    Atmospheric
                                                                    Pressure
                                                                    Negative
                                                                    Pressure
                      ON                                                                       ON



                                                                                                                              A23480



In sequence B and E, to determine the leak criterion, the vacuum pump creates negative pressure in the
canister pump module through the 0.02 inch orifice. If the pressure is out of specified range or is not satu-
rated, the ECM illuminates the MIL and sets DTCs P043E, P043F, P2401, P2402 and P2419 (2-trip detec-
tion logic).
  EVAP Pressure during EVAP Monitor

     Purge VSV                           OFF                                                        OFF          ON: Open
                                                                                                                 OFF: Closed
     Vent Valve                          OFF                                                        OFF          ON: Closed
                                                                                                                 OFF: Vent
  Vacuum Pump                            ON                                                         ON



                                                                                                                  Malfunction
                                                               Malfunction
 EVAP Pressure
      -1 kPa                                                    OK                                                OK

     Specified                                                   Malfunction                                      Malfunction
     Range

    -4.85 kPa

     Sequence              A              B                            C                   D        E
                        10               60                                               10        60
           Time         sec.             sec.
                                                                Within 15 minutes
                                                                                                    sec.
                                                                                          sec.
                                                                                                                              A23903
DI-356
                                                        DIAGNOSTICS         -   ENGINE (1GR-FE)

MONITOR STRATEGY
                                                                   P043E                             0.02 inch orifice clog (built-in pump module)
              Related DTCs
              R l t d DTC
                                                                   P043F                             0.02 inch orifice high-flow (built-in pump module)
      Required sensors/components              Pump module
          Frequency of operation               Once per driving cycle
                    Duration                   Within 2 min.
                  MIL operation                2 driving cycles
          Sequence of operation                None


TYPICAL ENABLING CONDITIONS
                                                                                            Specification
                      Item
                      It
                                                                  Minimum                                                Maximum
The monitor will run whenever these
                                                                                          See page DI-18
DTCs are not present

Atmospheric pressure                                                              70 to 110 kPa (525 to 825 mmHg)
Battery voltage                                                     10.5 V                                                   -
Vehicle speed                                                           -                                            2.5 mph (4 km/h)
Ignition switch                                                                                 OFF
EVAP pressure sensor malfunction
                                                                                            Not detected
(P0450, P0452, P0453)
EVAP canister purge valve                                                             Not operated by scan tool
EVAP canister vent valve                                                              Not operated by scan tool
EVAP leak detection pump                                                              Not operated by scan tool
Both of the following conditions are met
                                                                                         Condition 1 and 2
before IG switch OFF
1. Duration that vehicle is driven                                  5 min.                                                   -
2. EVAP purge operation                                                                      Performed