Service Manuals, User Guides, Schematic Diagrams or docs for : . Car Manuals Toyota Tundra 2000-2006 Approved 04-06 techinfo.toyota.com ileaf 06toyrm 06toypdf 06rmsrc 06tundra di eg1grfe cip04514

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
cip04514


>> Download cip04514 documenatation <<

Text preview - extract from the document
                                                                                                                                  DI-243
                                                  DIAGNOSTICS        -   ENGINE (1GR-FE)
                                                                                                                                     DIDTQ-01




    DTC                 P0450               Evaporative Emission Control System Pres-
                                            sure Sensor/Switch


    DTC                 P0451               Evaporative Emission Control System Pres-
                                            sure Sensor/Switch Range/Performance


    DTC                 P0452               Evaporative Emission Control System Pres-
                                            sure Sensor/Switch Low Input


    DTC                 P0453               Evaporative Emission Control System Pres-
                                            sure Sensor/Switch High Input

DTC SUMMARY
                                                                                                              Detection Tim-    Detection
 DTC          Monitoring Items           Malfunction Detection Conditions              Trouble Areas
                                                                                                                  ings           Logic
                                                                                  S Pump module              S EVAP monitor-
                                       Sensor output voltage rapidly fluctuates
         Pressure sensor voltage ab-                                              S Connector/Wire harness     ing (ignition
 P0450                                 beyond upper and lower malfunction                                                       1 trip
         normal fluctuation                                                         (Pump module - ECM)        OFF)
                                       thresholds for 0.5 seconds.
                                                                                  S ECM                      S Ignition ON
                                                                                  S Pump module              S EVAP monitor-
                                       Sensor output voltage fluctuates fre-      S Connector/Wire harness     ing (ignition
P0451    Pressure sensor noising                                                                                                2 trip
                                       quently in certain time period.              (Pump module - ECM)        OFF)
                                                                                  S ECM                      S Engine running
                                                                                  S Pump module
                                                                                                             S EVAP monitor-
                                       Sensor output voltage does vary in cer-    S Connector/Wire harness
P0451    Pressure sensor stuck                                                                                 ing (ignition    2 trip
                                       tain time period.                            (Pump module - ECM)
                                                                                                               OFF)
                                                                                  S ECM
                                                                                  S Pump module              S Ignition ON
                                       Sensor output voltage is less than 0.45    S Connector/Wire harness   S EVAP monitor-
P0452    Pressure sensor voltage low                                                                                            1 trip
                                       V for 0.5 seconds.                           (Pump module - ECM)        ing (ignition
                                                                                  S ECM                        OFF)
                                                                                  S Pump module              S Ignition ON
                                      Sensor output voltage is more than 4.9      S Connector/Wire harness   S EVAP monitor-
P0453    Pressure sensor voltage high                                                                                           1 trip
                                      V for 0.5 seconds.                            (Pump module - ECM)        ing (ignition
                                                                                  S ECM                        OFF)

HINT:
The pressure sensor is built into the pump module.
CIRCUIT DESCRIPTION
The circuit description can be found in the EVAP (Evaporative Emission) Inspection Procedure (see page
DI-368).
DI-244
                                                   DIAGNOSTICS   -   ENGINE (1GR-FE)

MONITOR DESCRIPTION
 Pressure Sensor Specification:                         (a)   DTC P0450: Pressure sensor voltage abnormal fluctua-
                                                              tion.
                                Malfunction Area
 Output Voltage                                               If the pressure sensor voltage output rapidly fluctuates
                                                              between less than 0.45 V and more than 4.9 V, the ECM
  4.900 V
                                                              interprets this as an open or short circuit malfunction in
  4.150 V                                                     the pressure sensor or its circuit, and stops the EVAP
                                                              (Evaporative Emission) system monitor. The ECM then il-
                                Usable Range
                                                              luminates the MIL and sets the DTC (1 trip detection log-
  1.425 V
                                                              ic).
                                Malfunction Area
                                                        (b)   DTC P0451: Pressure sensor noising or stuck
  0.450 V
                                                              If the pressure sensor voltage output fluctuates rapidly for
                  60      110      Pressure
                  kPa     kPa                                 10 seconds, the ECM stops the EVAP system monitor.
 HINT:                                                        The ECM interprets this as noise from the pressure sen-
 Standard atmospheric pressure is 101.3 kPa
                                               B17403         sor, and stops the EVAP system monitor. The ECM then
                                                              illuminates the MIL and sets the DTC.
                                                              Alternatively, if the sensor voltage output does not
                                                              change for 10 seconds, the ECM interprets this as the
                                                              sensor being stuck, and stops the monitor. The ECM then
                                                              illuminates the MIL and sets the DTC.
                                                              (Both the malfunctions are detected by 2 trip detection
                                                              logic)
                                                        (c)   DTC P0452: Pressure sensor voltage low
                                                              If the pressure sensor voltage output is below 0.45 V, the
                                                              ECM interprets this as an open or short circuit malfunction
                                                              in the pressure sensor or its circuit, and stops the EVAP
                                                              system monitor. The ECM then illuminates the MIL and
                                                              sets the DTC (1 trip detection logic).
                                                        (d)   DTC P0453: Pressure sensor voltage high
                                                              If the pressure sensor voltage output is 4.9 V or more, the
                                                              ECM interprets this as an open or short circuit malfunction
                                                              in the pressure sensor or its circuit, and stops the EVAP
                                                              system monitor. The ECM then illuminates the MIL and
                                                              sets the DTC (1 trip detection logic).
                                                                                                                                       DI-245
                                                    DIAGNOSTICS           -   ENGINE (1GR-FE)

MONITOR STRATEGY
                                                                                                Evaporative emission control system pressure
                                                                 P0450
                                                                                                sensor/switch chattering
                                                                                                Evaporative emission control system pressure
                                                                                                sensor noise
                                                                 P0451
                                                                                                Evaporative emission control system pressure
              Related DTCs
                                                                                                sensor stuck
                                                                                                Evaporative emission control system pressure
                                                                 P0452
                                                                                                sensor/switch low input
                                                                                                Evaporative emission control system pressure
                                                                 P0453
                                                                                                sensor/switch high input

      Required sensors/components           Pump module
          Frequency of operation            Once per driving cycle
                                            0.5 sec.: P0450, P0452, P0453
                    Duration
                                            10 sec.: P0451
                                            Immediate: P0450, P0452, P0453
                  MIL operation
                                            2 driving cycles: P0451

          Sequence of operation             None


TYPICAL ENABLING CONDITIONS
                                                                                        Specification
                      Item
                      It
                                                               Minimum                                            Maximum
The monitor will run whenever these
                                                                                       See page DI-18
DTCs are not present

Pressure sensor noise:
Atmospheric pressure                                                           70 to 110 kPa (525 to 825 mmHg)
Battery voltage                                                  10.5 V                                               -
IAT                                                                                4.4 to 35