Service Manuals, User Guides, Schematic Diagrams or docs for : . Car Manuals Toyota Tundra 2000-2006 Approved 04-06 techinfo.toyota.com ileaf 06toyrm 06toypdf 06rmsrc 06tundra di eg1grfe cip24192

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
cip24192


>> Download cip24192 documenatation <<

Text preview - extract from the document
                                                                                                                          DI-345
                                                 DIAGNOSTICS        -   ENGINE (1GR-FE)
                                                                                                                             DIDU8-01




    DTC                P2419               Evaporate Emission System Switching
                                           Valve Control Circuit Low


    DTC                P2420               Evaporate Emission System Switching
                                           Valve Control Circuit High

CIRCUIT DESCRIPTION
Refer to the EVAP Inspection Procedure (see page DI-368).
                                                                                                            Detection   Detection
 DTCs        Monitoring Item                 DTC Detection Conditions                     Trouble Areas
                                                                                                             Timing      Logic
                                      One of following conditions are met:
                                      S 0.02 inch orifice low-flow
                                      S 0.02 inch orifice high-flow
                                      S Vacuum pump ON stuck                     S Pump module              While
        Vent valve stuck ON
P2419                                 S Vacuum pump OFF stuck                    S Connector/Wire harness   Ignition
        (Closed)                                                                                                        2 trips
                                      S Vent valve ON (Closed) stuck               (Pump module - ECM)      switch
                                       NOTE:                                     S ECM                      OFF
                                       P043E, P043F, P2401, P2402 and P2419
                                       have same DTC detection conditions.
P2420   Vent valve stuck OFF (Vent)   Vent valve OFF (Vent) stuck

WIRING DIAGRAM
Refer to the EVAP Inspection Procedure (see page DI-368).
DI-346
                                                    DIAGNOSTICS        -   ENGINE (1GR-FE)

MONITOR DESCRIPTION
5 hours* after the ignition switch is turned OFF, the electric vacuum pump creates negative pressure (vacu-
um) in the EVAP (Evaporative Emission) system. The ECM monitors for leaks and actuator malfunctions
based on the EVAP pressure.
HINT:
*: If the engine coolant temperature is not below 35_C (95_F) 5 hours after the ignition switch is turned off,
the monitor check starts 2 hours later. If it is still not below 35_C (95_F) 7 hours after the ignition switch is
turned off, the monitor check starts 2.5 hours later.
Sequence         Operations                                                  Descriptions                                             Duration
    -      ECM activation           Activated by soak timer, 5 hours (7 or 9.5 hours) after ignition switch turned to OFF.               -
                                    Vent valve turned OFF (vent) and EVAP system pressure measured by ECM in order to
           Atmospheric pressure     register atmospheric pressure.
    A                                                                                                                               10 seconds
           measurement              If EVAP pressure is not between 70 kPa and 110 kPa (525 mmHg and 825 mmHg), ECM
                                    cancels EVAP system monitor.
           First 0.02 inch leak     In order to determine 0.02 inch leak pressure standard, vacuum pump creates negative pres-
    B      pressure measure-        sure (vacuum) through 0.02 inch orifice and them ECM checks if vacuum pump and vent             60 seconds
           ment                     valve operate normally.
                                    Vent valve turned ON (closed) to shut EVAP system.
                                    Negative pressure (vacuum) created in EVAP system, and EVAP system pressure then
           EVAP system pres-
    C                               measured.                                                                                       15 minutes*
           sure measurement
                                    Write down the measured value as it will be used in the leak check.
                                    If EVAP pressure does not stabilize within 15 minutes, ECM cancels EVAP system monitor.
                                    Purge VSV opened and then EVAP system pressure measured by ECM.
    D      Purge VSV monitor                                                                                                        10 seconds
                                    Large increase indicates normal.
           Second 0.02 inch leak    Leak check is performed after second 0.02 inch leak pressure standard is measured.
    E      pressure measure-        If stabilized system pressure higher than second 0.02 inch leak pressure standard, ECM          60 seconds
           ment                     determines that EVAP system leaking.
    F      Final check              Atmospheric pressure measured and then monitoring result recorded by ECM.                            -

* If only a small amount of fuel is in the fuel tank, it takes longer for the EVAP pressure to stabilize.


  Operation A: Atmospheric Pressure Measurement                            Operation B: 0.02 Inch Leak Pressure Measurement

                               Canister
                                                Fuel Tank


                                      Vent Valve: OFF (vent)                                            OFF            OFF (vent)

 Purge VSV: OFF
 0.02 Inch Orifice
 Pressure Sensor
                                                       Air Filter                                       ON

 Vacuum Pump: OFF      Pump Module
             Operation C: EVAP Leak Check                                                   Operation D: Purge VSV monitor



                         OFF          ON (closed)                                                       ON              ON (closed)

                                                                       Atmospheric
                                                                       Pressure
                                                                       Negative
                                                                       Pressure
                         ON                                                                              ON



                                                                                                                                             A23480
                                                                                                      DI-347
                                            DIAGNOSTICS   -   ENGINE (1GR-FE)

(a)    P2419: Vent valve stuck ON (Closed)
       In sequence B and E, to determine the leak criterion, the vacuum pump creates negative pressure in
       the canister pump module through the 0.02 inch orifice. If the pressure is out of specified range or is
       not saturated, the ECM illuminates the MIL and sets DTCs P043E, P043F, P2401, P2402 and P2419
       (2-trip detection logic).
  EVAP Pressure during EVAP Monitor

      Purge VSV                     OFF                                                OFF    ON: Open
                                                                                              OFF: Closed
       Vent Valve                   OFF                                                OFF    ON: Closed
                                                                                              OFF: Vent
  Vacuum Pump                        ON                                                ON



                                                                                               Malfunction
                                                    Malfunction
 EVAP Pressure
       -1 kPa                                         OK                                        OK

      Specified                                       Malfunction                               Malfunction
      Range

      -4.85 kPa

       Sequence         A             B                       C                 D      E
                       10             60                                        10     60
            Time       sec.          sec.
                                                     Within 15 minutes
                                                                                       sec.
                                                                                sec.
                                                                                                           A23903
DI-348
                                                     DIAGNOSTICS       -   ENGINE (1GR-FE)

(b) P2420: Vent valve stuck OFF (vent)
In sequence C, the vent valve turns ON (closes) and the EVAP (Evaporative Emission) system pressure is
then measured by the ECM, using the pressure sensor, to conduct an EVAP leak check. If the pressure does
not increase when the vent valve turned ON (closed), the ECM interprets this as the vent valve being stuck
OFF (vent). The ECM illuminates the MIL and sets the DTC.
    EVAP Pressure when Vent Valve Stuck OFF (vent):

      Purge VSV                                                                                         ON                    ON: Open
                                                                                                                              OFF: Closed

      Vent Valve                                                                 ON                                           ON: Closed
                                                                                                                              OFF: Vent
  Vacuum Pump                                                                   ON


 EVAP Pressure
      Positive
      Negative
                                                             OK

  First 0.02 inch
  Leak Pressure
  Standard
                                                        Malfunction
      Sequence                    A            B                           C                            D          E
                                  10          60                                                        10       60
            Time                  sec.        sec.
                                                                   Within 15 minutes
                                                                                                        sec.     sec.
                                                                                                                                       A23666



MONITOR STRATEGY
                                                               P2419                           Vent valve stuck open
                 Related DTCs
                 R l t d DTC
                                                               P2420                           Vent valve stuck closed
      Required sensors/components         Vent valve
          Frequency of operation          Once per driving cycle
                    Duration              Within 2 minutes
                  MIL operation           2 driving cycles
          Sequence of operation           None


TYPICAL ENABLING CONDITIONS
                                                                                        Specification
                      Item
                      It
                                                             Minimum                                                Maximum
The monitor will run whenever these
                                                                                       See page DI-18
DTCs are not present

Atmospheric pressure                                                           70 to 110 kPa (525 to 825 mmHg)
Battery voltage                                                10.5 V                                                    -
Vehicle speed                                                      -                                             2.5 mph (4 km/h)
Ignition switch                                                                             OFF
EVAP pressure sensor malfunction (P450,
                                                                                        Not detected
P0452, P0453)

EVAP canister purge valve                                                         Not operated by scan tool
EVAP canister vent valve                                                          Not operated by scan tool
EVAP leak detection pump                                                          Not operated by scan tool
                                                                                                                                    DI-349
                                               DIAGNOSTICS    -     ENGINE (1GR-FE)


Both of the following conditions are met
                                                                             Condition 1 and 2
before IG switch OFF

1. Duration that vehicle is driven                      5 min.                                                   -
2. EVAP purge operation                                                          Performed
ECT                                                                       4.4 to 35