Image preview - the first page of the document
>> Download Eurocap [snap-in] GPP Series documenatation <<Text preview - extract from the document GPP Series
Features
* Small low profile
* 10mm terminal spacing for direct PCB mounting
* Aluminium case with explosion proof vent
* 2000 Hour lifetime
Item Performance Characteristics
Operating Temperature Range -40 to +85 deg C -25 to +85 deg C
Working Voltage Range 10 to 100 Volts D.C. 160 to 450 Volts D.C.
Nominal Capacitance Range 470 to 68000 uF 47 to 2700 uF
Capacitance Tolerance +/- 20 % ( 120 Hz), 20 deg C
Leakage Current (+20deg C) I <=0.02 CV after 5 Minutes
Less than the value below:
WVDC 10~16 25~35 50~63 80~100 160~250 350~450
uF
Dissipation Factor % 47~390 15 20
(120 Hz, +20 deg C) 470~3900 25 20 20 20 15 20
4700~8200 35 30 30 25
10000~22000 40 35 30
27000~47000 45 40 35
56000~68000 50 45
Impedence Ratio at 120 Hz
Stability at Low Temperature -25 to +20 deg C : 3 max
-40 to +20 deg C : 12 max
Test conditions
Duration time: 2000 Hrs
Ambient temperature: +85 deg C
Load Life Applied voltage: Rated working voltage
Ripple Current: Maximum rated ripple current.
After testing--Measure at 20 deg C.
Capacitance change: <= +/- 20% of initial measured value
Dissipation factor: <= 200% of initial specified value
Leakage current: <= The initial specified value
Test Conditions
Duration time: 500 Hrs
Ambient temperature: +85 deg C
Applied voltage: None
Shelf Life
After testing--Measure at 20 deg C.
Same limits as for load life.
Pre-treatment: The measurements shall be conducted after application
of the Working D.C. voltage for 30 minutes.
Marking White print on black sleeve
Physical Dimensions and Mounting Details
The capacitors can also be supplied with an optional 4mm (+/-1mm) long terminal.
Mounting holes TERMINALS
in P.C.B.
Safety Vent
Eurocap International Limited.
Tel. +44 (0)1992 625407. E-Mail: [email protected]
Fax +44 (0)1992 625420. Website: www.eurocap-int.com/eurocap GPP Pg. 1 of 5