Text preview - extract from the document
 GPP Series
                  Features
              *   Small low profile
              *   10mm terminal spacing for direct PCB mounting
              *   Aluminium case with explosion proof vent
              *   2000 Hour lifetime

                Item                                                         Performance Characteristics
 Operating Temperature Range                         -40 to +85 deg C                                     -25 to +85 deg C
 Working Voltage Range                              10 to 100 Volts D.C.                                160 to 450 Volts D.C.
 Nominal Capacitance Range                           470 to 68000 uF                                        47 to 2700 uF
 Capacitance Tolerance                                                       +/- 20 % ( 120 Hz), 20 deg C
 Leakage Current (+20deg C)                                                   I <=0.02 CV after 5 Minutes
                                        Less than the value below:
                                                   WVDC      10~16          25~35           50~63         80~100     160~250    350~450
                                                uF
 Dissipation Factor %                   47~390                                                                          15        20
 (120 Hz, +20 deg C)                    470~3900               25             20              20            20          15        20
                                        4700~8200              35             30              30            25
                                        10000~22000            40             35              30
                                        27000~47000            45             40              35
                                        56000~68000            50             45
                                        Impedence Ratio at 120 Hz
 Stability at Low Temperature           -25 to +20 deg C : 3 max
                                        -40 to +20 deg C : 12 max
                                        Test conditions
                                        Duration time:                  2000 Hrs
                                        Ambient temperature:            +85 deg C
 Load Life                              Applied voltage:                Rated working voltage
                                        Ripple Current:                 Maximum rated ripple current.
                                        After testing--Measure at 20 deg C.
                                        Capacitance change:             <= +/- 20% of initial measured value
                                        Dissipation factor:             <= 200% of initial specified value
                                        Leakage current:                <= The initial specified value
                                        Test Conditions
                                        Duration time:                  500 Hrs
                                        Ambient temperature:            +85 deg C
                                        Applied voltage:                None
 Shelf Life
                                        After testing--Measure at 20 deg C.
                                        Same limits as for load life.
                                        Pre-treatment: The measurements shall be conducted after application
                                        of the Working D.C. voltage for 30 minutes.
 Marking                                White print on black sleeve


 Physical Dimensions and Mounting Details
              The capacitors can also be supplied with an optional 4mm (+/-1mm) long terminal.




                                                                                      Mounting holes               TERMINALS
                                                                                        in P.C.B.
                  Safety Vent


Eurocap International Limited.
Tel. +44 (0)1992 625407.                       E-Mail: [email protected]
Fax +44 (0)1992 625420.                      Website: www.eurocap-int.com/eurocap                                       GPP Pg. 1 of 5
 GPP Series
           Ir (A) specified at 85