Samcon [radial thru-hole] ELR Series


>> Download Samcon [radial thru-hole] ELR Series documenatation <<

Text preview - extract from the document
Samcon Radial Lead Aluminum Electrolytic Capacitors
             ELR                              SERIES
                                                                                                                RoHS
                                                                                                                compliance
  Load Life of 2000 Hours at 105
  Extended Temperature Range - 40 ~ +105
  ELR Series Aluminum Electrolytic Capactors are Small Sized High Reliable, LOW IMPEDANCE Capacitors
  Specially designed for small sized switching power supplies


 SPECIFICATIONS
                   Item                                                                                      Characteristics
Category Temperature Range                                                                                   - 40 ~ +105
            Voltage Range                                                                                    6.3 ~100 V.DC
      Nominal Cap. Range                                                                                     0.1 ~ 15000 F
   Capacitance Tolerance                                                              - 20% ~ + 20% (at 20, 120Hz)
                                                                        I = 0.01CV or 3(A) whichever is greater.(after 2 minutes)
          Leakage Current
                                                 where,I: Max Leakage Current(A), C: Nominal Capacitance(F), V: Rated Voltage(V) (at 20)

  Dissipation Factor (tan)                         WV    6.3     10    16    25     35     50   63 100
      ( at 120Hz, +20 )                           tan 0.16 0.14 0.12 0.10 0.10 0.08 0.08 0.06
                                                  Add 0.02 per 1,000 F for more then 1,000 F items

   Low Temp. Impedance                                      W. V .                 6.3     10       16     25        35    50    63    100
     Stability at 120Hz                           Z( - 25 ) / Z ( + 25 )            4      3        2      2         2      2     2     2
                                                  Z( - 40 ) / Z ( + 25 )            8      6        4      4         3      3     3     3

                                                 After 2000 hours' application of DC rated working voltage at 105, the capacitor shall meet the following limits:
                                                 Capacitance Change ...