Service Manuals, User Guides, Schematic Diagrams or docs for : . Rare and Ancient Equipment Ericsson Mobile Phones ERICSSON EF738 TestService

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
TestService


>> Download TestService documenatation <<

Text preview - extract from the document
       Test/Service Programs
Ericsson Mobile Phone EF738
Test/Service Programs




2
                                                Test/Service Programs


                   Contents
Test Equipment_____________________________________ 5
  Recommended Instruments _________________________________ 5
  Other Equipment__________________________________________ 6
Test Program_______________________________________ 7
  How to Use _______________________________________________ 7
    Initiating the Test Program ______________________________________ 7
    Return to TEST INPUT ________________________________________ 7
    Exit ________________________________________________________ 7
  Individual Test Options ____________________________________ 8
    Overview of the Test Program __________________________________ 15
ETACS Service Program ____________________________ 17
  Hardware Requirements___________________________________           17
  Software Installation ______________________________________       18
  Starting the Program _____________________________________         18
  The Programming Cycle___________________________________           19
  Using the Menus _________________________________________          19
    How to Select _______________________________________________       19
    The Functions _______________________________________________       20
      File_____________________________________________________         20
      Edit ____________________________________________________         21
      Short Numbers____________________________________________         31
      Options _________________________________________________         31
  Re-Programming a Telephone ______________________________ 32
  Contents of Saved Short Number Files _______________________ 32
Keypad NAM Programming _________________________ 33
  Long NAM Programming__________________________________ 34
    Programmable Parameters _____________________________________ 34
    Programming Instructions _____________________________________ 36
    Default Values ______________________________________________ 38
  Quick NAM Programming _________________________________ 40
    Programmable Parameters _____________________________________ 40
    Programming Instructions _____________________________________ 41
    Default Values ______________________________________________ 42
Flash Programming ________________________________ 43
  Introduction _____________________________________________ 43
  Hardware Requirements___________________________________ 43
  Software Setup ___________________________________________ 43
    Installing the Shell Program ____________________________________ 44
    Installing a Flasher Program____________________________________ 44
  Flash Operation __________________________________________ 45
    Hardware Setup _____________________________________________ 45
    Flashing Instructions__________________________________________ 45




                                                                        3
Test/Service Programs




4
                                                                         Test/Service Programs


Test Equipment
             The type of equipment required for service on the Ericsson Mobile Phone EF738 is
             listed below and includes instruments, tools, and other hardware.
             Descriptions of the programs for test, service, NAM programming, ESN transfer,
             and software upgrading are also included in the following subsections.


             Recommended Instruments
             Instrument                       Recommended Unit
             Alternative 1:
             Radio Test System                Marconi 2960
             lternative 2:
             Communication Test Set           Schlumberger 4031
             Alternative 3:
             Communications Test Set          Schlumberger 4015
             Alternative 4:
             Radio Test Set                   Rohde & Schwarz CMS 52
             Signalling Unit                  Rohde & Schwarz CMS-B13
             Other alternatives:
             Oscilloscope                     Tektronix 2235
             Multimeter                       Hewlett-Packard 3468A
             Digital Voltmeter                Fluke 8060A
             Power Supply Unit                Power Box EK030-10


                    POWER SUPPLY                         GROUND CABLE (black)
                                                             SUPPLY CABLE (red)

                                   GROUND SUPPLY
                                                              ANTENNA CABLE

                                                                  ANTENNA ADAPTER

                                                                                         D
                INSTRUMENT (FRONT)                                                       U
                                                                     C
                                         RF IN/OUT                                       M
    IN-AUDIO-OUT                                                     A
                                                                                         M
                                                                     R
                                                                                         Y
                                                                     C
                                                                                         B
                                                                     R
                                                                                         A
                                                                     A
                                                                                         T
                                                                     D
                                                                                         T
                                                                     L
                                                                                         E
                                                                     E
                                                                                         R
                                                                                         Y




         DB-9
    IN - AF - OUT
                              LPC
                     DB-15
                             102 280
      KRY 101 1612/2




                                                                                                 5
Test/Service Programs


                Other Equipment
                Equipment                             Ordering Number
                ETACS Service Program
                Programming Interface                 NTZ 112 311
                Connection Cable                      KRY 101 1135/10
                Adapter                               LPC 102 280
                Car Cradle                            KRY 109 1001/72
                Test Handset                          NTZ 112 210
                Antenna Cable                         NTZ 112 294
                Antenna Cable Adapter                 RNT 403 012/003
                Dummy Battery                         NTZ 112 310
                Service Adapter Kit
                - Test Interface Box                  LPC 102 280
                - Audio Box                           KRY 101 1612/51
                - Power Supply 110V                   KRY 101 1612/54
                - Power Supply 220V                   KRY 101 1612/55
                Standard tools and soldering equipment must also available
                Note: When servicing mobile telephones, it is most important that a bench earthing
                network is used to protect sensitive components against electrostatic discharge
                (ESD).




6
                                                                  Test/Service Programs


Test Program

        How to Use
        This document will describe the use of the built-in test program for the EF738.
        After the more extensive descriptions found in Individual Test Options, an overview
        follows in the form of a table with data referring to the different options.
        This table will become a handy alternative after having some experience of the test
        program.

        Initiating the Test Program
        The test program is initiated from the special test handset;
        by holding down the M button and pressing 90 40 59 or
        by pressing 90 40 59 followed by M M
        However, if the Test Program Enter function is enabled in the telephone, the pro-
        gram can be initiated and run directly from the keypad by pressing the same
        sequence (M = MENU).
        When the phone enters the test mode, the hardware becomes initialized and the text
        TEST INPUT appears in the display.
        To step forward and backwards in the test program; press SEND and RCL.
        To choose a specific test; press its number followed by the # button.

        Return to TEST INPUT
        Press the C or M button to return to the input mode where the TEST INPUT prompt
        is displayed.

        Exit
        To exit from the test program; select test option 99 and press the # button.




                                                                                            7
Test/Service Programs


                Individual Test Options
                A list describing the use of the test program options follows below.
                A summary of the test options and possible parameter values is given as well.


                1 CH NUMBER Setting of channel number
                            Choose any chanel in the ETACS system (0-600, 1329-2047).
                            Default setting is channel 1.
                            To change channel number; enter a 4-digit decimal number fol-
                            lowed by #.
                            Use * and # to step backwards/forwards.
                            Channel number and signal strength are displayed.
                2 TX POWER         Sets the transmitter on and offF and determines the output power
                                   level.
                                   8      off
                                   7      power level 7; minimum output power
                                   6      power level 6
                                   5      power level 5
                                   4      power level 4
                                   3      power level 3
                                   2      power level 2; maximum output power
                                   When the power reduction function is activated in menu 76,
                                   power level 2 will be displayed as `S'.
                                   When the extra power option in menu 76 is activated,
                                   power level 2 will be displayed as `X'.
                4 FLASHER          Used only when loading the program into a terminal.
                5 PWR CAL          Calibration of power levels.
                                   Transmitter is turned on and tuned to the calibration channel.
                                   Modify the power levels with the following keys:
                                   # / * increases/decreases the power level
                                   M+S stores the value and steps to next power level;
                                         transmitter is turned on
                                   M+# starts calibration and displays power level;
                                         steps forward to next power level (2->3->...->7->2).
                                   C     turns off TX, restores channel no., returns to menu 0.
                6 TX DETECT        Performs two simple transmitter tests: a general Go/NoGo trans-
                                   mitter test and a transmitter leakage test.
                                   To start the test, press any key except C.
                                   The result is displayed when the test is finished:
                                   FF both tests passed
                                   01     general transmitter test failed
                                   02     leakage test failed
                7 TX SENS          Factory and level 5 repair only




8
                                                      Test/Service Programs


9 RF CAL         Calibrates the RSSI levels based on the level of the signal cur-
                 rently being received.
                 The value determined for each level is the minimum strength
                 signal for that level, averaged over 16 readings to provide a
                 more reliable value.
                 The value for level 0 is used to update the Receiver Carrier
                 Detect (RXCD) such that signals below this level are ignored.
                 This value (plus a fixed offset) also determines the minimum
                 signal threshold for the AFC.
                 When the received signal is below this threshold, the AFC pro-
                 vides TCXO compensation based on a default temperature com-
                 pensation table.
                 The values for level 1 and 5 are used to determine the RSSI
                 graph to display.
                 The values for level 2, 3 and 4 are interpolated from these two
                 reference levels.
                 M+# displays the next RSSI level number and its current value
                 M+S reads an averaged RSSI value and stores it
10 RX SENS       Adjustment of the receiver audio output
                 M+# enables calibration and echoes the initial value
                 # / * increases/decreases the value by 1; new value is echoed
                 M+S stores the current value
11 KEYPAD        Factory and level 5 repair only
13 BANDGAP       Factory and level 5 repair only
14 AUDIO DEV Adjustment of the audio deviation
             M+# enables calibration and echoes the initial value
             # / * increases/decreases the value by 1; new value is echoed
             M+S stores the current value
15 AFC           Sets the AFC operating mode and displays AFC information
                 0      only temperatue compensation
                 1      temp. + age compensation
                 2      temp. + age + freq. compensation, smoothed (default)
                 3      temp. + age + freq. compensation, no smooth
                 4      no compensation
                 Any other code entered in handset mode will display:
                 ABCCDDEEFF where
                 A = AFC operating mode
                   0 only temperatue compensation
                   1 temp. + age compensation
                   2 temp. + age + freq. compensation, smoothed (default)
                   3 temp. + age + freq. compensation, no smooth
                   4 no compensation




                                                                                 9
Test/Service Programs


                             B = AFC state
                              1 waiting for signal;
                                 (no valid RSSI, compensate for temp. or temp. + age)
                              2 acquiring lock;
                                 (RSSI good, use whole freq. error for 1.5 sec for fast lock)
                              3 locked (RSSI good, use smoothed freq. compensation)
                              4 freeze lock ( RSSI temporarily lost, compensate for
                                 temp + age + (frozen) freq. error for up to 30 sec.)
                              5 locked using short count;
                                 (RSSI good, use smoothed freqcompensation);
                                 only entered when current savings is active;
                                 short freq. measurements is used to find freq. error com-
                                 pensation
                              6 entered when DRX has started;
                                 compensate for temp. + age + (frozen) freq. error.
                             CC total compensation
                             DD temperature table component
                             EE age component
                             FF frequency error component
                18 DAC2CAL   Calibration of the VCTCXO.
                             M+# enables calibration and echoes the initial value
                             # / * increases/decreases the value by 1; new value is echoed
                             M+S stores the current value
                             During the calibration the AFC is in `Temperature only compen-
                             sation mode' (Tp-15:0)
                             Upon exiting the calibration the AFC returns to its previously
                             selected operating mode.
                19 RX SAT    Factory and level 5 repair only
                20 AUDIO     Sets the audio paths in the audio circuit
                             Key TX-audio           RX-audio
                             0      muted           muted
                             1      unmuted         muted
                             2      muted           unmuted
                             3      unmuted         unmuted
                21 HANDSET   Sets the audio paths in the handset.
                             0      microphone off, earphone off, loudspeaker off (default)
                             1      microphone on, earphone on, loudspeaker off
                             2      microphone off, earphone off, loudspeaker on
                22 TX SAT    Controls the SAT tone switch and TX SAT deviation.
                             0     generate 5970 Hz SAT
                             1     generate 6000 Hz SAT
                             2     generate 6030 Hz SAT
                             3     no SAT generated
                             4     SAT tone switch setting = ON
                             5     SAT tone switch setting = OFF
                             M+# enables calibration and echoes the initial value
                             # / * increases/decreases the value by 1; new value is echoed
                             M+S stores the value




10
                                                        Test/Service Programs


23 MANCH OUT Controls the wideband data and deviation
             To transmit these data the transmitter must be switched on.
             0     off - no data output)
             1     8kHz output; ones
             2     8kHz output; zeros
             3     hardcoded idle frame; 0101010101
             M+# enables calibration and echoes the initial value
             # / * increases/decreases the value by 1; new value is echoed
             M+S stores the value
24 MANCH IN       Displays the latest received data from the base station.
                  The value is displayed each time a key is pressed.
25 VOLUME         Sets the earpiece and loudspeaker volume.
                  Possible values: 0 - 7 (default: 3)
26 DTMF           DTMF tones consist of a lower frequency in combination with a
                  higher frequency.
                  The test enables listening to either or both as follows:
                  0     low frequency
                  1     high frequency
                  2     both frequencies.
                  # / * scroll forwards/backwards to next/previous DTMF tone
                  M+# enables calibration and echoes the initial value
                  # / * increase/decrease the value by 1; new value is echoed
                  M+S stores the value
27 TX SOURCE Sets the TX audio paths in the audio circuit.
             Also possible to adjust the levels of the different audio paths.
             0      external line input, ATMS (default)
             1      internal MIC
             2      internal MIC with MicAmp gain
             M+# enables calibration and echoes the initial value
             # / * increases/decreases the value by 1; new value is echoed
             M+S stores the value
28 EARPIECE       Sets the earpiece mute switch in the audio circuit to allow for
                  adjustment of the earpiece sensitivity values.
                  0     internal earpiece disconnected
                  1     internal earpiece connected
                  2     audio sent out AFMS on system connector (default)
                        internal earpiece and AFMS can both be adjusted
                  M+# enables calibration and echoes the initial value
                  # / * increases/decreases the value by 1; new value is echoed
                  M+S stores the value
29 COMP           Selects compander or linear mode
                  M+# displays the current compander settings
                  M+0 linear mode (default)
                  M+1 companding mode




                                                                                    11
Test/Service Programs


                30 HF           Controls the handsfree attenuation level for RX and TX audio
                                M+0       selects RX handsfree audio gain settings
                                          and echoes initial gain settings
                                M+1       selects TX handsfree audio gain settings
                                          and echoes initial gain settings
                                0-7       sets the gain for the selected path:
                                          0=0dB, 1=-7dB, 2= -14dB, ... 7=-49dB
                32 SOFTLIMIT Sets the use of the softlimiter in the audio circuit.
                             Changes made are temporary and will not update the EEPROM.
                35 COUNTRY      Factory and level 5 repair only
                36 BER          Factory and level 5 repair only
                37 OMC          Factory and level 5 repair only
                38 ADC          Displays the different hex values from the ADC
                                M+1      RSSI
                                M+2      battery voltage
                                M+3      unused
                                M+4      temperature sense
                                M+5      bandgap reference
                                M+6      current sense
                                M+7      handsfree level
                39 DAC          Changes temporarily the output voltage from the DAC.
                                M+1      normally controlled by AFC
                                M+2      normally trimmed using `MENU 18'
                                M+3      power level
                                xxx M+# decimal value followed by `MENU + #' sent directly
                                         to the active DAC (valid values: 000 - 255)
                                #/*      increases/decreases value by 1; new value is echoed
                40 INPORT       Shows the status of the different inports (updated every second)
                                M+1     external audio connection detected
                                        0 = input high
                                        1 = input low
                                M+2     state of CPU port 2
                                M+3     flip status
                                        0 = flip closed
                                        1 = flip open
                                M+4     transmitter status
                                        0 = transmitter off
                                        1 = transmitter on
                                M+6     external handsfree detected
                                        0 = input low
                                        1 = input high
                                M+7     receiver carrier detect
                                        0 = RSSI < sensitivity limit
                                        1 = RSSI > sensitivity limit
                                #       immediately reads the selected port




12
                                                       Test/Service Programs


41 OUTPORTS      Shows the status of the selected outport
                 First select a digital outport:
                 M+1+0 VRX
                 M+1+1 VTX, Note! VRX must be on!
                 M+1+2 power down VCO
                 M+1+3 unused
                 M+1+4 SWDC
                 M+1+5 MPD2
                 M+1+6 FMPD1
                 M+1+7 unused
                 M+1+8 temperature
                 M+2       ICTRL
                 M+3       MUTE
                 M+4       green LED
                 M+5       red LED
                 M+6       back light
                 Then select the state:
                 0         set output low
                 1         set output high
42 DSCR          Turns the discriminator and multiplier on and off
                 0        discriminator off
                 1        discriminator on (default)
43 BAR           Tests the different tones of the phone
                 0         continous ringing signal at maximum volume
                 1         continuos alarm signal
                 2         click signal single pulse
                 3         error signal single pulse
                 4         continuous 3kHz ringing tone
45 LCD           Tests the different segment and icons of the display as five dif-
                 ferent patterns
                 M+digit (1-5)shows the selected pattern no. (1-5)
                 #               shows all patterns continuously
                                 starting with pattern no. 1
                 C or S          terminates the test
46 PWR DOWN Factory and level 5 repair only
47 SW REV        Displays the software, revision and ESN inside the terminal.
                 Press any key to show software name and revision.
                 Additional pressure of any key will show the ESN.
48 SYNTH         Factory and level 5 repair only
49 RX PWR        Factory and level 5 repair only
   MODE
50 GUARANTEE Press any key to display year and month when warranty/guaran-
             tee was activated and the length (months)of the warranty period
53 SYNT I SET    Factory and level 5 repair only
54 EEPROM        Factory and level 5 repair only
   INIT




                                                                                13
Test/Service Programs


                60 SYNTH         Factory and level 5 repair only
                61 AUDIO         Factory and level 5 repair only
                   CIRCUIT
                62 RADIO CTRL Factory and level 5 repair only
                74 TCA TEST      Checks the ETACS combining algorithm
                76 BATT SAVE     Controls the reduced and extra power functions
                                 0     off
                                 1     power reduction invoice channel (power level 2 only)
                                 2     extra power (power level 2 only)
                77 EEDATA        Factory and level 5 repair only
                79 PIN           Factory and level 5 repair only
                91 EEPROM        Factory and level 5 repair only
                   DUMP
                92 EEPROM        Factory and level 5 repair only
                   LOAD
                96 COLD START Clears the RAM, exits service & test mode, and powers up in
                              `terminal charge only mode'
                              #     exit service & test mode; power up in normal mode
                              M+# exit service & test mode; power up in charge only mode
                97 FLASH         Calculates the checksum of the flash memory
                   CHSUM         #     2 bytes checksum will be displayed
                98 ERROR         Factory and level 5 repair only
                99 EXIT          Press # to exit the service program




14
                                                  Test/Service Programs


Overview of the Test Program
Menu            Possible Values
1 CH NUMBER     0-600, 1329-2047
2 TX POWER      8 (off) - 2 (maximum power)
4 FLASHER       only used when loading program into terminal
5 PWR CAL       calibration of power levels
6 TX DETECT     simple test of transmitter
7 TX SENS       factory and level 5 repair only
9 RF CAL        RSSI calibration
10 RX SENSE     adjustment of receiver audio output
11 KEYPAD       factory and level 5 repair only
13 BANDGAP      factory and level 5 repair only
14 AUDIO DEV    adjustment of maximum audio deviation
15 AFC          sets AFC operating mode and displays AFC information
18 DAC2CAL      calibration of VCTCXO
19 RX SAT       factory and level 5 repair only
20 AUDIO        sets audio paths in audio circuits
21 HANDSET      sets audio paths in handset
22 TX SAT       controls SAT tone switch and TX SAT deviation
23 MANCH OUT    controls wideband data and deviation
24 MANCH IN     displays latest received data from base station
25 VOLUME       sets earpiece and loudspeaker volume
26 DTMF         DTMF tones
27 TX SOURCE    sets TX audio paths in audio circuit
28 EARPIECE     sets earpiece mute switch in audio circuit
29 COMPAND      selects compander/linear mode
30 HF           controls handsfree attenuation level for RX and TX audio
32 SOFTLIMIT    sets use of softlimiter in audio circuit
35 COUNTRY      factory and level 5 repair only
36 BER          factory and level 5 repair only
37 OMC          factory and level 5 repair only
38 ADC          displays different hex values from ADC
39 DAC          changes temporarily output voltage from DAC
40 INPORTS      shows status of different inports



                                                                      15
Test/Service Programs


                Menu               Possible Values
                41 OUTPORTS        selects status of selected outport
                42 DISCR           turns discriminator/multiplier on/off
                43 BAR             tests different tones of phone
                45 LCD             tests different segments and icons of display
                46 PWR DOWN        factory and level 5 repair only
                47 SW REV          displays software, revision and ESN inside terminal
                48 SYNTH           factory and level 5 repair only
                49 RX PWR MODE     factory and level 5 repair only
                50 GUARANTEE       warranty information
                53 SYNT I SET      factory and level 5 repair only
                54 EEPROM INIT     factory and level 5 repair only
                60 SYNTH           factory and level 5 repair only
                61 AUDIO CIRCUIT   factory and level 5 repair only
                62 RADIO CTRL      factory and level 5 repair only
                74 TCA TEST        checks ETACS combining algorithm
                76 BATT SAVE       controls reduced and extra power functions
                77 EEDATA          factory and level 5 repair only
                79 PIN             factory and level 5 repair only
                91 EEPROM DUMP     factory and level 5 repair only
                92 EEPROM LOAD     factory and level 5 repair only
                96 COLD START      powers up in `terminal charge only mode'
                97 FLASH CHSUM     calculates checksum of flash memory
                98 ERROR           factory and level 5 repair only
                99 EXIT            press # to exit service program




16
                                                                 Test/Service Programs


ETACS Service Program
       The ETACS Service Program is a tool used for entering the initializing customer
       parameters into the EEPROM of the Ericsson mobile phone EF738.
       This description of the ETACS Service Program includes information on:
       



◦ Jabse Service Manual Search 2026 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo