           SERVICE MANUAL




                        EC Chassis

Modification reserved
Eco Eco Chassis Service Manual




2
                                                                           Eco Eco Chassis Service Manual




Table Of Contents

Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Component description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Service Instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Adjustment procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Troubleshooting guide for main chassis . . . . . . . . . . . . . . . . . . . . . . . . .24
Scart specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Description of the circuit
*STV2110B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
*STV8224A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
*STV8225 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37
*TDA8174 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
*STV8223 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
*TDA2822M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
*TEA5101B . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
*BUH515D . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
*CF70095ANW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55
*CF70200NW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
*CF72306 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
**Spare Part list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61
Exploded view
layout of the pcb's and circuit diagrams




                                                                                                                 3
Eco Eco Chassis Service Manual




TECHNICAL DATA

F.TXT CRT PANEL                               Ultra                        Ultra S.TXT               Ultra
Visible Picture                               37cm                         37cm                      37cm
Deflection Angle                              90                           90                        90
Vertical Frequency                            50Hz                         50Hz                      50Hz
Horizontal Frequency                          15.625Hz                     15.625Hz                  15.625Hz




ELECTRONIC
Program Number         64+1 AV                           64+1 AV                         64+1 AV
Teletext               -                                 Simple Text                     Fast Text
Tuner                  VST                               VST                             VST
                       Including Hyper Band              Including Hyper Band            Including Hyper Band
TV Standards           Pal-Secam                         Pal-Secam                       Pal-Secam
                       B/G-L/L'-I-DK                     B/G-L/L'-I-DK                   B/G-L/L'-I-DK
Music Power            1W                                1W                              1W




CONNECTIONS

Euro AV Socket           Including                         Including                        Including




MAIN STAGE

Mains Voltage               175-250VAC                        175-250VAC                   175-250VAC
Mains Frequency             50Hz                              50Hz                         50Hz
Power Consumption           60W                               60W                          60W
Power Consumption
In Stby Mode                10W                               10W                          10W




4
                                                                           Eco Eco Chassis Service Manual




RECOMMENDATION FOR SERVICE REPAIRS
1- Use only original spare parts. Only use components         volve a shock hazard from the receiver.
   with the same specifications for replacement.              Servicing should not be attempted by anyone who
2- Original fuse value only should be used.                   is not thoroughly familiar with the precautions
3- Main leads and connecting leads should be chec-            necessary when working on high voltage equip-
   ked for external damage before connection.                 ment.
   Check the insulation.                                      Perfectly discharge the high potential of the pictu-
4- Parts contributing to the safety of the product must       re tube before handling the tube. The picture tube
   not be damaged or obviously unsuitable.                    is highly evacuated and if broken.
   This is valid especially for insulators and insulating     Glass fragments will be violently expelled.
   parts.                                                     Always discharge the picture tube anode to the re-
5- Thermally loaded solder pads are to be sucked off          ceiver chassis to keep of the shock hazard before
   and re-soldered.                                           removing the anode cap.
6- Ensure that the ventilation slots are not obstructed.    8- Keep wire away from the high voltage or high tem-
7- Potentials as high as 25 KV are present when this re-       perature components.
   ceiver is operating. Operation of the receiver           9- When replacing a wattage resistor in circuit board,
  outside the cabinet or with back cover removed in-           keep the resistor 10 mm away from circuit board.




HANDLING OF MOS
CHIP COMPONENTS
MOS circuit requires special attention with regard to          til they are used. Most components must never be
static charges. Static charges may occur with any              stored in styropor materials or plastic magazines.
highly insulating plastics and can be transferred to        2- Persons have to rid themselves of electrostatic char-
persons wearing clothes and shoes made of synthetic            ges by touching MOS components.
materials. Protective circuits on the inputs and outputs    3- Hold the component by the body touching the ter-
of mos circuits give protection to a limited extend only       minals.
due to time of reaction.
                                                            4- Use only grounded instruments for testing and pro-
Please observe the following instructions to protect the       cessing purposes.
components against damage from static charges.              5- Remove or connect MOS ICs when operating volta-
1- Keep mos components in conductive package un-               ge is disconnected.




X-RAY RADIATION
PRECAUTION
1- Excessive high voltage can be produce potentially           voltage be recorded as a part of the service re-
   hazardous X-RAY radiation. To avoid such hazard,            cord. It is important to use an accurate and reliab-
   the high voltage must not be above the specified li-        le high voltage meter.
   mit. The nominal value of the high voltage of this re-   2- The primary source of X-RAY radiation in this TV re-
   ceiver is 25KV at zero beam current (minimum                ceiver is the picture tube. For continued X-RAY radi-
   brightness) under 220V AC power source. The high            ation protection, the replacement tube must be
   voltage must not under any circumstance, exceed             exactly the same type tube as specified in the part
   30KV. It is recommended the reading of the high             list.


                                                                                                                  5
Eco Eco Chassis Service Manual




                                 POWER CORD



                                 SAW FILTER



                                 IR SENSOR



                                 VOLTAGE REGULATOR



                                 ON/OFF SWITCH


                                 LINE FILTER

                                 PTC

                                 NPN TRANSISTOR

                                 PNP TRANSISTOR

                                 CERAMIC FILTER

                                 COIL

                                 LINEARITY COIL

                                 FUSIBLE RESISTOR

                                 IW METAL OXIDE RESISTOR

                                 1/2W METAL OXIDE RESISTOR

                                 1/4 OR 1/6W CARBON FILM RESISTOR

                                 CERAMIC CAPACITOR /POLYESTER CAPACITOR

                                 ELECTROLYTIC CAPACITOR

                                 DIODE

                                 ZENER DIODE

                                 SWITCH JUMPER

                                 NET (INPUT)

                                 NET (OUTPUT)

                                 TACT SWITCH
6
                                                                              Eco Eco Chassis Service Manual




SERVICE
INSTRUCTION
      VCR COMPUTER AND DECODER CONNECTIONS ...........8
      - Video Cassette recorder (VCR) connection . . . . . . . . . . . . . . .
      - Decoder Connection
      - VCR Connection via Scart Socket
      - Computer Connection via Scart Socket
      - Decoder Connection via Scart Socket


      OPERATION OF THE TELEVISION
      - Power On . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
      - Stand by Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
      - Programme Number Selection . . . . . . . . . . . . . . . . . . . . . . . . .9
      - Mute Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
      - AV Selection Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
      - Analogue Level Selection Key . . . . . . . . . . . . . . . . . . . . . . . . .11
          - Brightness Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
          - Colour Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
          - Contrast Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
          - Volume Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
          - Status Key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13

      PROGRAMMING THE TV CHANNELS
      - Power Off . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
      - Access to The Menu Program . . . . . . . . . . . . . . . . . . . . . . . . .14
      - Selection of The Desired Function . . . . . . . . . . . . . . . . . . . . . .14
      - Automatic Channel Searching . . . . . . . . . . . . . . . . . . . . . . . .14
      - Band Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
      - Memorisation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
      - Skipping unused Program Positions . . . . . . . . . . . . . . . . . . . . .16
      - Stopping Automatic Searching . . . . . . . . . . . . . . . . . . . . . . . .16
      - Fine Tuning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
      - Changing The Program Number . . . . . . . . . . . . . . . . . . . . . . .17
      - Standard Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
      - Memorisation of Analogue Levels . . . . . . . . . . . . . . . . . . . . . .18

      SLEEP TIMER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
      TELETEXT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19


                                                                                                           7
Eco Eco Chassis Service Manual




8
Eco Eco Chassis Service Manual




                             9
Eco Eco Chassis Service Manual




10
Eco Eco Chassis Service Manual




                            11
Eco Eco Chassis Service Manual




12
Eco Eco Chassis Service Manual




                            13
Eco Eco Chassis Service Manual




                                 s




14
            Eco Eco Chassis Service Manual




s




    s   s




                                        15
Eco Eco Chassis Service Manual




                                 s
           s




                            s




16
Eco Eco Chassis Service Manual




                            17
Eco Eco Chassis Service Manual




                                 s




18
Eco Eco Chassis Service Manual




                            19
Eco Eco Chassis Service Manual




20
                                                                  Eco Eco Chassis Service Manual




ADJUSTMENT PROCEDURE

Due to the concept, all the following   adjust-      LF3 to get correct demodulation and 4,5 volts on
ments can be performed after a short warming         pin 2 (AFC).
time (1 minute)                                      4.1.2 With a spectrum analyzer
                                                     Switch off the AFC by grounding the IDENT signal.
1. POWER SUPPLY                                      The analyzer probe is connected at the output
Adjust with potentiometer PP1, 105 volts on DP 10    of the TUNER. Connect the RF generator with
cathode.
                                                     Tuner input (The choice of frequency doesn't
                                                     influence the adjustment result).
2. SCANNING ADJUSTMENTS                              Tuner until you find frequency at 38.9 on PT4.
2:1 Horizontal:
                                                     Adjust LF3 - see 4.1.1-.
Adjust R14 for correct Phase
                                                     4:2 AGC
2:2 Vertical
                                                     Connect RF generator with a signal of 2mV on
Adjust RD11 (Vertical amplitude) to get correct      mid range VHF high.
picture height,
                                                     Adjust potentiometer RF 10 on the threshold of
                                                     voltage decreasing on pin 1 of the Tuner (PT6).
3. COLOUR DECODER ALIGNMENT
INSTRUCTION                                          5. ADJUSTMENTS DEPENDING ON THE
The procedure is recommended as follows:
                                                     PICTURE TUBE
BAR pattern generator in SECAM.                      First adjust Focus with special points pattern with
At first the SECAM bell filter has to be aligned     medium contrast and correct brightness.
with L4. Use first a scope on pin 17 IC1             Cut off is performed automatically, G2 is
Color identification must be adjusted by L1 test     adjusted to get black level at 150/160 volts on
point on PT3. readjust BELL filter test point PT3.   green cathode, depending on the picture tube
Discriminator Blue and Red adjusted by L3 test       specification.
point on pin 26. PT2, and I 2 test point on pin      PV1 (blue gain) and PV2 (red gain) allow to
29.(Control by the eye on a grey colored             adjust the white you need, with color analyzer or
pattern).                                            compared with a reference.
Adjust R25 DL level for egalizing amplitude of       Peak and mean beam current limited are
direct and delayed lines (PT3 or the eye) Switch     adjusted by software.
to a PAL DEM pattern, and adjust phase of delay
line with L5 (using a scope or the eye).
                                                     6. UNITEXT
                                                     LT1 adjustment: Pin 2 of ICT1 adjust 64 