SERVICE MANUAL
                       RMX90DVS



      MODEL NO.: RMX90DVS
                         Contents
Specification                        1-3
Block Diagram                        4
Packing View                         5
Packing View Part List               6
Point To Point Wiring Diagram        7
Exploded View                        8
Exploded View Part List             9-10
Electrical Part List                11-23
Schematic Diagram                   24-28
Printed Circuit Board Diagram       29-36
IC Block Diagram                    37-55
   General Specification
1. Power Source            AC100~240 V
2. Dimensions              322 (W)mm x 387 (L)mm x 107.5 (H) mm
3. Weight                  6.85 Kg

4. Audio Characteristics
   ( Unbalance Output Load = 100K ohm , Balance Output Load = 600 OHM
   {Signal to Signal 600 OHM },Phones = 33 ohm ,
   EQ/Filter Flat , Fader At Max. Unless Otherwise Noted)

5. INPUT/OUTPUT IMPEDANCE & SENSITIVITY: ( 1KHz INPUT , MIC/AUX, TRIM, MASTER AT
   MAX. )
   5-1. INPUT IMPEDANCE AND REFERENCE INPUT LEVEL:
    LINE/CD                  45K OHM /0dBV(1V)
    PHONO                    47K OHM /-35dBV(3.16mV)
    AUX                       45K OHM /0dBV(200mV)
    MIC1/2                    5K OHM /-42dBV(1.99mV) (Unbalance)

   5-2. OUTPUT IMPEDANCE AND REFERENCE OUT LEVEL:
                                              Nominal                   Limited
   MASTER              1K OHM /-2.2dBV (776mV)   