>> Download r_azal documenatation <<Text preview - extract from the document Technical Bulletin No. RTB-001
SUBJECT: Service Manual Correction DATE: Sept. 15, '96
PAGE: 1 of 4
PREPARED BY: N. Kaiya FROM: 1st Field Information Dept. QAC
CHECKED BY: T. Inoue
CLASSIFICATION: MODEL:
Action Required Revision of service manual Azalea
Troubleshooting Information only
Retrofit Information Other
Please add the following between step 3 on page 3-7 and step 4 on page 3-8.
Language ROM Installation Procedure
NOTE:
The following procedure given by sub-steps numbered (1) through (6) are
required only for A166-26,27, A187-26,27 and A189-26,27 copiers .
This procedure should be done between steps 3 and 4 of the copier
installation procedure.
[d]
[b]
[a]
[c]
A166I597.wmf
(1) Remove the right upper bracket [a] (1 screw).
(2) Remove the left upper bracket [b] (1 screw).
(3) Remove the front upper cover [c] (2 screws).
(4) Remove the operation panel [d] (4 screws).
Technical Bulletin No. RTB-001
SUBJECT: Service Manual Correction DATE: Sept. 15, '96
PAGE: 2 of 4
(5) -For A166-26,27, A187-26,27 copiers-
Turn the operation panel [a] upside-down and install the required language ROM [b]
into the socket numbered IC40 on the SCU board.
-For A189-26, 27 copiers-
Turn the operation panel [c] upside-down and install the requred language ROMs [d]
into the sockets numbered IC6, 7, 8 and 9 on the SCU board in accordance with
the IC-number label on each IC.
-A166-26, 27, A187-26, 27 copiers-
[b]
[a]
A166I598.wmf -A189-26, 27 copiers- [d]
[c]
(6) Reinstall the following parts.
A166I596.wmf