Service Manuals, User Guides, Schematic Diagrams or docs for : . Various Guildline Guildline6564Datasheet

<< Back | Home

Most service manuals and schematics are PDF files, so You will need Adobre Acrobat Reader to view : Acrobat Download Some of the files are DjVu format. Readers and resources available here : DjVu Resources
For the compressed files, most common are zip and rar. Please, extract files with Your favorite compression software ( WinZip, WinRAR ... ) before viewing. If a document has multiple parts, You should download all, before extracting.
Good luck. Repair on Your own risk. Make sure You know what You are doing.




Image preview - the first page of the document
Preview not available!
Sorry, no preview image available for this document.
Possible reasons are : this is not a PDF document, it is password protected or the file is partially corrupted.
We are working to fix the issue.
You can still download the full file from the link below and it will be viewable.



>> Download Guildline6564Datasheet documenatation <<

Text preview - extract from the document
                                                                   Model 6564 Series
                        8 AND 16-CHANNEL HIGH TO ULTRA-HIGH RESISTANCE SCANNERS

                     First Commercially Available High to Ultra High Resistance Scanner

                                                       Guildline's 6564 High to Ultra-High Resistance
                                                       Scanners are the first commercial scanners capable of
                                                       operating with measurement capabilities to 10 P 's (1015) and
                                                       at voltages to 1000 Vdc. This capability has never previously
                                                       been commercially available, and will greatly improve the
                                                       measurement and calibration throughput of high and ultra-
                                                       high ohm resistors now that standard laboratories can easily
                                                       and quickly automate a single or multiple resistance values.

           8 Channel Model Shown                       Use of the 6564 Scanners makes no material contribution
                                                       towards uncertainty based on noise or repeatability. As an
                                                       example, this means using the scanner has no measured effect
             6564SERIES FEATURES                       on Guildline's 6520 Teraohmmeter Transfer measurement
                                                       mode of operation throughout the entire range of the meter.
       Withstands up to 1000 Vdc Providing Fully       Contributing less than 1 ppm of Leakage for measurements at
       Automated Resistance Measurements               100 G               the 6564 scanner has negligible effect on
       Measurements from 100k to 10P with No           the uncertainty contribution when used for direct reading
       Guarding Required                               measurements considering the uncertainty budgets of
                                                       measurements at these values. Furthermore, due to the
       Fully Automates 6520 Short Transfer
                                                       repeatability of the scanner's leakage, this leakage is easily
       Measurements
                                                       characterized and can be removed by specifying the offset. A
       Very Low Leakage which can be Easily            complete table of the error contribution due to leakage of the
       Characterized                                   6564 Scanner is provided on page 2 of this datasheet.
       Thermoelectric Potentials: <20 nV
                                                     The 6564 Series Scanners Provides >10015 Typical
       Contact Life: 10,000,000 Cycles
                                                     Isolation, Measurements to10P
       Front Panel or Remote GPIB Control
                                                     to 1000 V with No Guarding Required! True
       2 Terminal Switching Matrix, 8 or 16          Automation Capability for High to Ultra-High Value
       Channels                                      ResistanceisNowAvailableforEveryone!
       8 Channel is Upgradeable to 16 Channels
                                                       High and Ultra-High ohm resistance measurements are
       Gold Flashed Tellurium Copper Terminals         typically difficult to make and are very time consuming
       Front Panel Indication of Selected Channels     because of the low signal/noise ratio. With the Guildline model
                                                       6564 Scanners and software, these hard-to-make high ohm
                                                       measurements (up to 10 P) can now be automated and
                                                       scheduled at any time that is convenient to the metrologists,
                                                       even at night and over the weekends, when the lab is empty
                                                       and quiet.

                                                       8-channel and 16-channel models are available. Like other
                                                       Guildline products, the 8-channel scanner can be expanded to
                                                       a 16-channel model, giving our customers exactly what's
                                                       needed now and the flexibility for future growth.

                                                       The 6564 Scanners are provided with BNC, Triax and type N
                                                       connectors used by Guildline 6520 and 6500A Teraohmmeters.
                                                       Optional adaptors are provided to support BPO, BNC, and other
                                                       types of connections. The 6564 scanner accounts for all
                                                       necessary measurement connections.            The 6564 offers
                                                       convenient operation from either the front panel or from the
 Complete Automated High to Ultra-                     built in IEEE 488 bus. TeraCalTM Software included with the
High Resistance Measurement System!                    6520 has built-in drivers to automatically address the scanners.
6564 8 and 16-Channel, High to Ultra High Resistance Scanners
6564 Series Specifications
                                                                                                           Isolation Specifications
            Measured                                                6564 Leakage                                    6520 Transfer Mode            6520 Direct Reading       6636 Element Drift
         Resistance Value                                           Specification                                      Specification                 Specifications           Specifications
                                                                                                                                      (4 Hours)        (12 Month)                 (12 Month)
                    100 M                                                <0.1 ppm                                                 25 ppm               150 ppm                   15 ppm
                      1G                                                 <0.1 ppm                                                 25 ppm               200 ppm                    35 ppm
                     10 G                                                 0.1 ppm                                                 25 ppm               600 ppm                   100 ppm
                    100 G                                                   1 ppm                                                 25 ppm               800 ppm                   200 ppm
                      1T                                                   10 ppm                                                 80 ppm              1000 ppm                   500 ppm
                     10 T                                                 100 ppm                                                500 ppm              3500 ppm                   750 ppm
                    100 T                                                1000 ppm                                                700 ppm              6000 ppm                  1000 ppm
                      1P                                                     1%                                                 2000 ppm                 2.5%                       NA
                     10 P                                                    10%                                                5000 ppm                 30%                        NA


                                                                                                           General Specifications
     Thermoelectric Potentials:                                                   <20 nV typical and <50nV max.
                                                                                  Life: >10,000,000 cycles at low levels
                                                                                  Initial Contact Resistance: 0.05 max.
     Relay Contact Ratings:                                                       Current: 2A max at 10 V
                                                                                  Voltage Switched: 100 V max. at 1 mA
                                                                                  Voltage Non-Switched: 1000 V max.
     Leakage Resistance:                                                          10015
     Channel Outputs                                                              Male N Type Termination 



◦ Jabse Service Manual Search 2024 ◦ Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo