Text preview - extract from the document
   Global LCD Panel Exchange Center                 www.panelook.com




                                                                                                        SDI




                                             SPECIFICATIONS


                              106cm (42 Inch) Wide Plasma Display Module

                                                MODEL : S42SD-YD01

                                                      (PAL/NTSC)



              x   This specification will be approved by both Creative Technology Ltd and Samsung SDI

                  Co.,Ltd.
              * Please return one of this specification with your signature for approval.




                      Proposed by:                                                     Approved by:
                       Signature                                                            Signature
                      Manager
                      Customer Quality Group,
                      PDP Business Division,

                      Samsung SDI CO.,LTD




                                                  CONFIDENTIAL                    Spec. Rev. : Version 3




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center           www.panelook.com




                                                                                        S DI
                                             CONFIDENTIAL

                                    SAMSUNG SDI CO.,LTD.




                               Document: VSC-PRO-FSPPDP-01
                                         Version # 1.0
                                   Date: November 20, 2000




                                                          Version 3        2/2       16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center           www.panelook.com




                                                                                             S DI
                                             CONFIDENTIAL



                                           Revision History

            Revision           Date              Description Of Changes                    Approval

                 0           14.Feb.2002                 Newly established

                                             - Display Performance(6p)
                 1          07.May.2002      - Brightness Variation Specification(11p)
                                             - Input Signal Specifications(13-14p)

                 2          25.June.2002     - Input Power Voltage Specification(20-22p)



                 3         16.October.2002   - Input Power Specification(21p)




                                                            Version 3           3/2        16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center                               www.panelook.com




                                                                                                                                   S DI
                                                                CONFIDENTIAL



                                                         TABLE OF CONTENTS
           1 DESCRIPTION ............................................................................................. .4

           2 FEATURES ....................................................................................................4

           3 PRODUCT NAME AND MODEL NUMBER.......... ...............................................4

           4 FUNCTION OUTLINE .....................................................................................4

           5 BLOCK DIAGRAM .........................................................................................5

           6 DISPLAY CHARACTERISTICS................................................................6
             6.1 Display Performance ...................................................................................................6
             6.2 Display Cell Arrangement ...........................................................................................7
             6.3 Brightness Measurement Condition .................................................................................8
             6.4 Contrast Measurement Condition ....................................................................................9
             6.5 Display Cell defect specification. ....................................................................................10
             6.6 Brightness Variation Specification ..................................................................................11

           7. MECHANICAL CHARACTERISTICS.................................................................12
              7.1 Mechanical Specification..............................................................................................12
              7.2 Mechanical Characteristics............................................................................................12


           8. ENVIRONMENTAL CONDITION ......................................................................12
              8.1 Recomended Environment Condition ...............................................................................12

           9. INTERFACE SPECIFICATION .........................................................................13
              9.1 Input Signal Specification ...........................................................................................13
              9.2 Input Power Voltage Specification ................................................................................19

           10. APPENDIX ......................................................................................................25
              10.1. Mechanical Dimensions Drawing Front Side ...................................................................25
              10.2. Mechanical Dimensions Drawing Rear Side ...................................................................26

           11. RELIABILITY ................................................................................................ .......... 27
              11.1 MTBF ...................................................................................................................27
              11.2 Expected ServiceLife.................................................................................................27

           12. WARNINGS/ CAUTIONS / NOTICE....................................................................28
              12.1 Warning.................................................................................................................28
              12.2 Caution..................................................................................................................29
              12.3 Notice....................................................................................................................30




                                                                                     Version 3                 4/2              16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center               www.panelook.com




                                                                                                  S DI
                                                 CONFIDENTIAL

           1. DESCRIPTION

                The S42SD-YD01 is a 42-inch wide full color plasma display module with a resolution of
                852(H) 480(V) pixels. The display module includes Display Panel, Panel driving
                electronics, Logic controller and Power supply .

           2. FEATURES

                x Wide aspect ratio(16:9) 42 inch diagonal display screen. The display screen is 920
                  wide and 518 high.

                x Slim and light weight. The display module is 71      in depth and 22.5    in weight.

                x 16.77 million colors by combination of 8 bits R,G and B digital data

                x High brightness, High contrast, Wide viewing angle. The screen has a white
                  peak brightness of Typical 500cd/ , contrast of Typical 550:1 and a viewing angle of
                  greater than 160 comparable to that achievied with CRTs.

           3. PRODUCT NAME AND MODEL NUMBER

                x Product name : 42-inch Full Color Plasma Display Module
                   (abbreviation : PDP Module)
                x Model number : S42SD-YD01

           4. FUNCTION OUTLINE

                 x The plasma display module has APC(Automatic Power Control) function which restrict
                   power consumption within certain value without regard to display load ratio.

                x The plasma display module is operated at 50HZ or 60Hz frame rate. It is required
                 external frame rate conversion in order to display the other formats.

                x The plasma display module is made up of 4 types of input power voltages; Voltage for
                 operating Logic, Voltage for FET driver, Voltage for Column driver, and Voltage for
                  Display driver.

                x The plasma display module is operated at progressive signal only.
                  It is required external progressive scan conversion in order to display the other formats.

                x The plasma display module requires 90~240V, 50~60Hz of input power voltage



                                                                Version 3          5/2         16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center           www.panelook.com




                                                                                        S DI
                                             CONFIDENTIAL


           5. BLOCK DIAGRAM




                                                          Version 3        6/2       16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center              www.panelook.com




                                                                                                      S DI
                                                CONFIDENTIAL




           6. DISPLAY CHARACTERISTICS

             6.1 Display Performance

              No              Item                                           Rating

                                                             Horizontal 852     Vertical 480 pixels
               1          Display Pixels
                                                                   (1 pixel = 1 R,G,B cells)

               2          Display Cells                      Horizontal 2556     Vertical 480 cells

               3           Pixel Pitch                        Horizontal 1.08      Vertical 1.08

               4        Cell Arrangement                                 R,G,B Stripe

                                                         Horizontal 920.16           Vertical 518.4
               5      Effective Display Size
                                                           [ 36.23 inch (H)        20.41 inch (V) ]

               6        Number of Color                               16.77 million colors
                          Brightness *1
               7                                            Typical 500cd/ (module, LVDS input)
                        (Peak Brightness)
                        Contrast Ratio *2
               8                                                         Typical 550:1
                         (in dark room)
                                                     White              X = 0.285 0.03, Y = 0.290       0.03

                    Chromaticity Coordinates          Red               X= 0.645      0.03, Y= 0.345 0.03
               9
                        (Typical Value)              Green              X= 0.250      0.05, Y= 0.665 0.04
                                                     Blue               X= 0.155      0.04, Y= 0.090 0.04

               10       Viewing Angle *3                                  Over 160


              (Note)
               * 1. Brightness and Color Coordinates are the value that measured with 1% load ratio white
                    pattern. The condition for measurement is shown in Figure-3.
               * 2. Contrast Ratio is calculated from the display brightness and the non-display brightness
                    value, and display condition is shown in Figure-3.
               * 3. Viewing angle is the critical angle at which the brightness is reduced to 50% to the
                    brightness perpendicular to the PDP unit.




                                                                 Version 3            7/2          16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center           www.panelook.com




                                                                                        S DI
                                             CONFIDENTIAL


           6.2 Display Cell Arrangement




                                                          Version 3        8/2       16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center            www.panelook.com




                                                                                        S DI
                                              CONFIDENTIAL


           6.3 Brightness Measurement Condition

               (1) Display Pattern




                (2) Display Area ratio : 1% white window

                (3) Vsync : 16.7msec

                (4) Measuring equipment : MINOLTA CA-100

                (5) Ambient Temperature : Room Temperature

                (6) Ambient Light : dark Room (<2 lux)




                                                           Version 3       9/2       16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center                www.panelook.com




                                                                                                    S DI
                                                  CONFIDENTIAL


           6.4 Contrast Measurement Condition

                (1) Measurement point
                .




                (2) Vsync : 16.7 msec

                (3) Measuring Equipment : MINOLTA CA-100
                                          Pattern Generator(VG-828, LVDS Output).

                (4) Contrast Calculation fomula

                                   Brightness of 1% white window Area at the center of the screen
                 Contrast ratio
                                                   Brightness of black Area *1

                       Note
                       1. For mass production test purposes, it is recommended to measure just 1 point,
                         P1 of Figure.-4 on display pattern of Fig.-3.


                (5) Ambient Light : Dark Room (<2 lux)




                                                                   Version 3        10/2         16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center                 www.panelook.com




                                                                                                   S DI
                                                   CONFIDENTIAL


           6.5 Display Cell Defect Specification

                 In some cases, a panel may have defective cells that cannot be controlled.

                 These defective cells can be categorized into three types;
                 (1) Non-lighting cell defect : defect in which the cell is always off
                 (2) Non-extinguishing cell defect : defect in which the cell is always on
                 (3) Flickering cell defect : defect in which the cell is flickering

           The display cell defect specifications define the allowed limits for display cell defects and are
           used as the criteria in determining wether a panel is shipped.




                                                              Specification
                Item
                                Number of cell defects                 Distance between cell defects

            Non-lighting    z Zone A: 4 and less
            cell defect     z Zone B: 10 and less

            Non-
                            z Zone A: 1 and less
            extinguishing
                            z Zone B: 3 and less            Regardless of A and B zone,
            cell defect
                                                            The Distance between cell defects is over 10mm.
            Flickering      z Zone A: 1 and less            (single R,G,B and Black)
            cell defect     z Zone B: 3 and less

                            Total number of cell defects
            Total defect      Zone A and B
                              is 12 and less



                                                                 Version 3          11/2         16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center               www.panelook.com




                                                                                                   S DI
                                                 CONFIDENTIAL

           6.6 Brightness Variation Specification

               The color-PDP uses ultraviolet light produced by gas discharge to illuminate phosphor.
               Uneven phosphor coating and inconsistent discharge characteristics cause slight difference
               in brightness among the sections in a panel.
               The brightness variation specifications define the allowed limits for brightness differences
                and the criteria in determining whether a panel is shipped.



                 Item                                Definition                               Specification

                            The brightness is measured at 9 points (A1~A9 of Fig-6)
            Full white
                            on full white pattern.                                            10% and less
            brightness
                            The full white brightness variation as then calculated
            variation
                            from the following equations.


                            The Chromaticity Coordinates on Full white window;
            Color           Chromaticity Coordinates is measured at 9 points (A1~A9       x 0.015(average)
            variation       of Fig-6) on full white pattern                               y    0.015(average)




                         Max  x                         x  Min
                                    u 100%                     u 100%
                              x                           x




                                                                  Version 3       12/2          16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center                   www.panelook.com




                                                                                                        S DI
                                                      CONFIDENTIAL



           7. MECHANICAL CHARACTERISTICS
             7.1 Mechanical Specifications

                No          Item                                       Rating

                1          Outer         Width 1019.2     Height 616      Thickness 71
                         Dimensions      *see Appendix A1, A2 (Mechanical Dimensions Drawing)
                2         Weight         Approx. 22.5 kg



             7.2 Mechanical Characteristics

                No           Item                                        Rating
                                            Frequency      : 10 to 55Hz
                                            Sweep rate : 1minute/octave
                1          Vibration        Stroke : x,y direction : 0.35
                                            z-direction : 0.175
                                            Applied time : 30minutes/dir.

                                            Acceleration : less than 20G (X,Y-direction)
                2            Shock          less than 10G (Z-direction)
                                            Test time : 11 ms

              Notes: ( Test condition ) Non-Packaging, Non-Operational



           8. ENVIRONMENTAL CONDITIONS

             8.1 Recommended Environment Condition

                 No.            Item                                     Rating
                                            Operational              0 to 50
                           Temperature      Storage                  -15 to 60
                     1                      Temperature Slope        1.5 /minute max.
                           * MAXIMUM GLASS SURFACE TEMPERATURE MUST BE KEPT LESS THAN 80
                                            Operational              20 to 70 % RH (no condensation)
                    2      Humidity
                                            Storage                  20 to 80 % RH (no condensation)
                                            Operational              800 to 1114 hPa (Altitude : 0 to 2,000 m)
                    3      Pressure
                                            Storage                  600 to 1114 hPa (Altitude : 0 to 4,500 m)




                                                                     Version 3             13/2      16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center                 www.panelook.com




                                                                                                      S DI
                                                   CONFIDENTIAL



           9. INTERFACE SPECIFICATIONS
             9.1 Input Signal Specifications
             * The Location No. is possible to change to PBA Revision
                 (1) Input signal name and Pin assignment




              Note
             1. LA3 connector is located in Logic Board.
             2. Pin to Pin pitch of connector LA3 is 0.625 .
             3. Connector LA3(parts #:1554A-3141R ) is supplied by UJU
                Electronics. This Item is compatible with FI-WE*P.HF (JAE, JAPAN)
             4. The length of mating cable to LA3 is recommended to be not longer than 25.0 .
             5. Pin numbering order : right to left view from component side of Logic Board.
             6. Reserved for factory use only. This pin should be disconnected in case of customer's use.
                 This pin is output pin. In case of fan failure, this signal becomes high.




                                                                   Version 3          14/2         16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center                   www.panelook.com




                                                                                                   S DI
                                                    CONFIDENTIAL



                   z

                            SCALER BOARD LVDS                   LOGIC BOARD LVDS
                                 (DS90C385)                     (DS90CF386)               SIGNAL
                                                                                           NAME
                   PIN #            PIN NAME          PIN #           PIN NAME
                    31              TxCLKIN            26            RxCLKOUT             DCLK
                    51               TxIN0             27             RxOUT0          R0(LSB DATA)
                    52               TxIN1             29             RxOUT1               R1
                    54               TxIN2             30             RxOUT2               R2
                    55               TxIN3             32             RxOUT3               R3
                    56               TxIN4             33             RxOUT4               R4
                       2             TxIN5             34             RxOUT5          R7(MSB DATA)
                       3             TxIN6             35             RxOUT6               R5
                       4             TxIN7             37             RxOUT7               G0
                       6             TxIN8             38             RxOUT8               G1
                       7             TxIN9             39             RxOUT9               G2
                       8             TxIN10            41             RxOUT10              G6
                    10               TxIN11            42             RxOUT11         G7(MSB DATA)
                    11               TxIN12            43             RxOUT12              G3
                    12               TxIN13            45             RxOUT13              G4
                    14               TxIN14            46             RxOUT14              G5
                    15               TxIN15            47             RxOUT15         B0(LSB DATA)
                    16               TxIN16            49             RxOUT16              B6
                    18               TxIN17            50             RxOUT17         B7(MSB DATA)
                    19               TxIN18            51             RxOUT18              B1
                    20               TxIN19            53             RxOUT19              B2
                    22               TxIN20            54             RxOUT20              B3
                    23               TxIN21            55             RxOUT21              B4
                    24               TxIN22            1              RxOUT22              B5
                    25               TxIN23             2             RxOUT23
                    27               TxIN24             3             RxOUT24             Hsync
                    28               TxIN25             5             RxOUT25             Vsync
                    30               TxIN26             6             RxOUT26             D_EN
                    50               TxIN27             7             RxOUT27              R6



                           Note
                           1. LVDS Chip is supplied by National Semiconductor.




                                                                    Version 3      15/2       16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center                  www.panelook.com




                                                                                        S DI
                                                CONFIDENTIAL

                (2) Interface Circuit Diagram




                                                :




                                                :




             (3) Input signal Timing specification
              (3-1) PAL System




                                                              Version 3   16/2       16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center                        www.panelook.com




                                                                                                                   S DI
                                                          CONFIDENTIAL


           Symbo                         TIMING                          Unit                       Remark
           l
                         Minimum         Typical     Maximum
            TVSYNC        19.5             20.0           20.5           ms           Frame Frequency : 50Hz Typical
             tWV            1               1               4            H*1

             tVH            3               3                            H*1

             tHV            1              97                            H*1

            THSYNC        28.5           34.46            34.46

             tWH            4               8              16             D

             tHC           16              22                             D

             tCH           16              22                             D

             TCLK          34              38.5           38.5            ns

            tWCLK1         15            TCLK/2       TCLK-15             ns

            tWCLK2         15            TCLK/2       TCLK-15             ns

             tSUD          10                                             ns

             tHD           10                                             ns



             Notes :
              1. 1H = One cycle of Horizontal sync signal(=THSYNC)
              2. 1D = One cycle of Dot clock signal(=TCLK)
              3. If input display data in a horizontal period is 852 and less, the incorrect image is displayed

           (1) Electrical characteristics of Input signal

                                                                                              Value
                   No.           Items             Symbol           Condition                                             Unit
                                                                                    min.     typical     max.
                          Input Voltage:
                          LVDS Level
                1                                               -
                          1) "H" Level              VIH                              2.0        -        5.25              V
                          2) "L" Level              VIL                              -0.5       -            0.8           V
                          Input Current:
                          LVDS Level
                                                                VI =2.75V
                2         1) "H" Level              IIH                               -         -            1            mA
                                                                VCC =5.25V
                                                                VI =0.4V
                          2) "L" Level              IIL                               -         -            1            mA
                                                                VCC =5.25V



                                                                               Version 3       17/2              16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center           www.panelook.com




                                                                                        S DI
                                             CONFIDENTIAL



                (3-2) NTSC System




                                                          Version 3       18/2       16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center                        www.panelook.com




                                                                                                                  S DI
                                                          CONFIDENTIAL


           Symbo                          TIMING                         Unit                      Remark
           l
                         Minimum          Typical   Maximum
            TVSYNC        16.2              16.7          17.2           ms          Frame Frequency : 60Hz Typical
             tWV            1                  1           4             H*1

             tVH            3                  3                         H*1

             tHV            1                  1                         H*1

            THSYNC        28.5             34.46          34.46

             tWH            4                  8           16             D

             tHC           16                22                           D

             tCH           16                22                           D

             TCLK          34               38.5          38.5           ns

            tWCLK1         15              TCLK/2     TCLK-15            ns

            tWCLK2         15              TCLK/2     TCLK-15            ns

             tSUD          10                                            ns

             tHD           10                                            ns


             Notes :
              1. 1H = One cycle of Horizontal sync signal(=THSYNC)
              2. 1D = One cycle of Dot clock signal(=TCLK)
              3. If input display data in a horizontal period is 852 and less, the incorrect image is displayed




               (1) Electrical characteristics of Input signal




                                Input Voltage:
                                LVDS Level
                     1                                               -
                                1) "H" Level        VIH                             2.0        -        5.25             V
                                2) "L" Level        VIL                             -0.5       -            0.8          V
                                Input Current:
                                LVDS Level
                     2          1) "H" Level        IIH         VI =2.75V            -         -            1            mA
                                                                VCC =5.25V
                                2) "L" Level        IIL         VI =0.4V             -         -            1            mA
                                                                VCC =5.25V


                                                                              Version 3       19/2              16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center            www.panelook.com




                                                                                          S DI
                                              CONFIDENTIAL




           9.2 Input Power Voltage Specifications
              (1) Input Power Connector Location




              Note
                1. Layout Schematic is viewed from back side of PDP Module.
                   Input Power Connector is denoted as
                3. The Input Power Connector in Y-Drive Board is named as "SY".
                4. The Input Power Connector in X-Drive Board is named as "SX".
                5. The Input Power Connector in Logic Board is named as "SL".
                . The Input Power Connector in Column Drive Board is named as "BUFFER".




                                                           Version 3       20/2       16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center             www.panelook.com




                                                                                             S DI
                                               CONFIDENTIAL

             (2) Input Power Voltage Source and Pin Assignment
             Caution : If you would controll at will(not in spec), SMPS may operate `protection' mode.




                                                             Version 3        21/2        16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center           www.panelook.com




                                                                                        S DI
                                             CONFIDENTIAL




             (3) Input Power Specification




                 Note
                1. Typical Voltage of Va and Vs varies depending on Display Panel
                2. More detail specification is described in next page.
                3. `9Vcc' is same `V9A' pin. in `SA' connector.
                4. `12Vcc' is same `V12(A)' in `SA' connector or `V12A' in `AUDIO' connector.
                5. 12Vsp is same `VAMP' pin in `AUDIO' connector.




                                                          Version 3       22/2       16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center                 www.panelook.com




                                                                                        S DI
                                                CONFIDENTIAL




             (4) Detail Input Power Specification




                                                             Version 3    23/2       16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center           www.panelook.com




                                                                                        S DI
                                             CONFIDENTIAL



             (5) Protection




                                                          Version 3       24/2       16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center            www.panelook.com




                                                                                        S DI
                                              CONFIDENTIAL




             (10) Power Applying Sequence
                  (This Sequence is applicated only for Danam communication's SMPS)

                  Vcc applied   Vdd applied   Vs applied    Va applied




                                                           Version 3       25/2       16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center           www.panelook.com




                                                                                        S DI
                                             CONFIDENTIAL




           10. Appendix
              10.1. Mechanical Dimensions Drawing Front Side




                                                                                               .




                                                          Version 3       26/2       16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center           www.panelook.com




                                                                                        S DI
                                             CONFIDENTIAL




           10.2. Mechanical Dimensions Drawing Rear Side




                                                           Version 3      27/2       16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center                www.panelook.com




                                                                                                  S DI
                                                  CONFIDENTIAL




           11. RELIABLITY

              11.1 MTBF Value
                  Mean Time Between Failure is dependent on overall PDP module design.

                  MTBF : 20,000hours (environmental temperature : 25          )




              11.2 Expected Service Life

             #1. Definition
                 The expected service life is defined by the following two categories.
                 And the life time is defined by the reached time either (1) or (2).

                 (1) The white color brightness level becomes half (50%) of its initial value, which is
                     determined by the phosphor characteristics.

                 (2) The number of display cell deffects increases to double the specification value, which
                     is depending on the discharge characteristics.

             #2. Test condition and life time
                 The expected service life time differs with display conditions as below.

                 (1) Full screen white color display

                     Life time : 30,000 hours (this is not the guaranteed life)

                     * Test condition : 8Hr/Day




                                                                  Version 3       28/2         16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center               www.panelook.com




                                                                                                  S DI
                                                 CONFIDENTIAL


           12. WARNING / CAUTION / NOTICE

               TO PREVENT POSSIBLE DANGER, DAMAGE, AND BODILY HARM, PLEASE
              CONSIDER AND OBSERVE ALL WARNINGS AND CAUTIONS CONTAINED IN
              THIS PARAGRAPH.

            12.1 Warning

                If you don't consider the following warnings, it could result in death or serious injury
               (1) The PDP module is controlled by high voltage about 350V. If you need to handle the
                   module during operation or just after power-off, you must take proper precautions
                   against electric shock and never touch the drive circuit portion and metallic part of PDP
                   module.
                   The capacitors in the drive circuit portion remain temporarily charged even after the
                    power off. After turning off the power, you must be sure to wait at least one minute
                    before touching the module. If the remain voltage is strong enough, it could result in
                    electric shock.

               (2) Do not use any other power supply voltage than the specified voltage in this product
                  specifications. If you use deviated power voltage from the specifications, it could result
                  infire hazard or product failure.

               (3) Do not operate or install under the deviated surroundings from the environmental
                   specification such as in moisture or rain; near water-for example, bath tub, laundary tub,
                   kitchen sink; in a wet basement; or near a swimming pool; and also near fire or heater -
                   for example, near or over radiator or heat resistor; or where it is exposed to direct
                   sunlight; or somewhere like that. If you use the PDP module in places above, it could
                   result in electric shock, fire hazard or product failure.

               (4) If any foreign objects (e.g. water, liquid and metallic chip or dust) entered the PDP
                  module, the power supply voltage to the PDP module must be turned off immediately.
                  Also, never push objects of any kind into the PDP module as they may touch dangerous
                  voltage point or make short circuits that could result in fire hazard or electric shock.

               (5) If smoke, offensive smell or unusual noise should come from the PDP module, the
                   power supply voltage to the PDP module must be turned off immediately.
                   Also, when the PDP screen cannot display any picture after the power-on or during
                   operation, the power supply must be turned off immediately. Never continue to operate
                   the PDP module under these conditions.

               (6) Do not disconnect or connect the PDP module's connector while the power supply is on,
                  or just after power off. Because the PDP module is operated by high voltage, and the
                  capacitors in drive circuit remain temporarily changed even after the power is turned off.
                  If you need to disconnect or connect it, you have to wait at least one minute after power
                  off.

                                                                Version 3          29/2        16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center                www.panelook.com




                                                                                                    S DI
                                                  CONFIDENTIAL


              (7) Do not disconnect or connect the power connector by wet hand. The voltage of the
                product may be strong enough to cause an electric shock.

              (8) Do not damage the power cable of the PDP module, also do not modify it.

              (9) When the power cable or connector is damaged or frayed, do not use it.

             (10) When the power connector is covered with dust, please wipe it with a dry cloth before the
                  power on.


           12.2 Caution

               If you don't consider the following cautions, it may result in personal injury or damage to a
               propertied facilities.

             (1) Do not set the PDP module on an unstable place, vibrating place and inclined place. The
                 PDP module may fall or drop, and it may cause serious injury to a person, and serious
                 damage to the product.

            (2) If you need to remove the PDP module to another place, you must turn off the power supply
                and detach the interface cable and power cable from the PDP module, and watch your steps
                during the work. If the cable has a damage, it may result in fire hazard or electric shock.
                 Also if the PDP module drop or fall, it may result in personal injury

            (3) When you draw or insert the PDP's cable, you must turn off the power supply and do it with
                holding the connector. If you draw the cable, the electric wire in the cable is exposed or
                broken. It may result in fire hazard or electric shock.

            (4) When you carry the PDP module, you must do it by two workers in order to avoid
                unexpected accidents.

            (5) The PDP module has a glass-plate. If the PDP module is inflicted with excessive stress -
               for example; shock, vibration, bending and heat-shock, the glass plate could break. It may
               result in personal injury. And also, do not press or strike the glass surface.

            (6) If the glass panel was broken, do not touch it with bare hand. It may result in a cut injury.

            (7) Do not place any object on the glass panel. It may be the cause of the scratch or break
               the glass panel.

            (8) Do not place any object on the PDP module. It may result in personal injury due to fall or
               drop.




                                                                  Version 3         30/2         16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center                www.panelook.com




                                                                                                   S DI
                                                  CONFIDENTIAL

           12.3 Notice

           When you apply the PDP module to your system or handling it, you must make sure to follow
           the notices described below.

              Notice to your system design

           (1) The PDP module radiates the infrared rays of between 800 and 1000 . It may bring a miss
             operation to the IR-remote controller or another electric system. Please consider to provide the
              IR absorb filter in your system, and to take enough evaluation.

           (2) The PDP module has high-voltage switching circuit and high-speed clock circuit. Therefore,
               you have to apply and evaluate the EMC consideration in your system.

           (3) The PDP module has a glass plate. In your mechanical design, please consider to avoid a
              excessive shock and stress to the glass surface. Also be careful not to demage the tip-tube at
             the corner of glass plate. If the glass plate and tip-tube are demaged, the PDP module may fail.

           (4) In your system, for your safety, please consider that remain voltage of the PDP module
             should be leaked immediately after power-off.

           (5) As the PDP module generates heat during operation, please consider the well-radiation and
              well-ventilation in your system design. The PDP module may be defected on the usage out of
              specified ambient temperature.

           (6) The ventilation design in your system should be considered to provide the moisture-proof
             and dust proof because the PDP module has high-density dielectric parts with high-voltage.
             If the driver circuit has condensation or dusts, it may cause a short circuit or dielectric
             breakdown.

           (7) If the PDP module displays a fixed pattern on the screen for extended periods of time, it
              could make the differences of brightness and chromaticity between fixed pattern area and
              other areas. This is because the brightness of fixed pattern area becomes lower than the
              other areas due to degrading of the phosphor, but this phenomenon is not failure,.
             On the other hand, when the display pattern is changed, the areas where were illunminated
              may remain temporarily (few minutes) their brightness.
              This phenomenon is a characteristic of color PDP itself due to activation of the discharge
             surface in the PDP panel, and also it is not abnormal.
             If you have a intention to display the fixed pattern, the screen-saver technic should be
             applied to your systems in order to minimize image retention.

           (8) The PDP module is not intended for use with equipments which require extremely high
              reliability such as aerospace equipments, nuclear control systems or medical equipments
              for life support.

           (9) Based on the requirements of the safty standard (UL, EN etc.), be sure to add the filter that
              come up to the impact test to the glass plate.
                                                                 Version 3         31/2         16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center                www.panelook.com




                                                                                                   S DI
                                                  CONFIDENTIAL

              Notice to the operation and handling of the PDP module.

           (1) To prevent defect or failure, please check the cable connections and power-supply condition
               before power-on.

           (2) The PDP module is controlled by high voltage. Not only during operation but also
               immediately after power-off, never disconnect or connect the PDP module's connector
               because it may result in failure. If you need to disconnect or connect, you have to wait at
               least one minute after power-off.

           (3) The PDP module is equipped with various protection circuits that automatically stop the
               module operation if an interface signal or the power voltage becomes abnormal during
               operation. If the PDP module stop suddenly during operation, please check the conditions of
               input signal and power source before restart.

           (4) For protection of the circuit, if the abnormal situation is occured, the high output voltage
               will be shut downed by watching the input voltage (Vs/ Va/ Vcc) internally. In this case,
               the module power resetting is necessary to recover.
               There are also fuses in the Vs and Va power supply system to prevent smoking and firing by
               the excessive current. The protection function of the address driver by keeping watch for the
               internal current is provided in the Va power supply system. Therefore the number of sub-
               frames decreases to a proper value when the Ia current exceeds a constant value occasionally.

           (5) If the abnormal situation such as disconnecting of the input connector is occurred, this
              module will be on stan-by which high output voltage is stopped even if an external power is
              supplied. If a normal signal is input after this, normal operation state, operations will start
              again by re-inputting a normal signal. However it is necessary to rest th module power when
              tVH and/or tHV are less than the minimum value provide with specification

           (6) To ensure reliable operation of the PDP module and to protect it from overheating, never
              wrap or cover it with a cloth or like a sheet during power-on period. Also, never place the
              PDP module in a confined space or any other places of poor ventilation.

           (7) If you continue to watch the PDP screen for a long time, your eyes become fatigued. It is
             necessary to rest your eyes occasionally.

           (8) The PDP screen is controlled with the display-data signals and synchronized signals. If noise
              interferes with those signals, the PDP screen could become unstable and, in some case, would
              be led to failure. Do not place any equipment that generates exessive EMI/RFI noise near the
              interface cable of the PDP module, and keep the cables as short as possible.

           (9) Be careful not to break the glass panel when you handle the PDP module. Also, when
              handling the PDP module, you must wear gloves or other hand protection to prevent injuries
              that can occur if the glass panel breaks.

           (10) The glass panel section and drive circuit section of the PDP module are closely connected
               and functioned as a pair. If the module is arbitrarily recombined, restructured, or

                                                                 Version 3          32/2        16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center                www.panelook.com




                                                                                                   S DI
                                                CONFIDENTIAL
               disassembled, SDI will not be responsible for the fuction, quality, or operational integrity of
               the modified module. Do not recombine, restructure, or disassemble it.

           (11) To avoid possible electric shock, you must make sure the power supply voltage of PDP
               module is turned off before cleaning. To clean the PDP's glass panel, apply water or a
               natural detergent to a piece of soft cloth or gauze, and wring the cloth tightly before wiping
               the screen. Make sure that no water contacts the connecting terminals on the side of the glass
               panel. Never use chemical solvents, such as paint thinner or benzene, to clean the glass
               panel.

           (12) The drive circuit section of PDP module uses C-MOS intergrated circuits that must be
               protected from static electricity. Therefore when transporting or delivering the module, be
               sure to put the module in an antistatic bag. When handling the PDP module, take adequate
               grounding precautions to prevent static electricity.

           (13) When delivering or transporting the PDP module, you must take special precautions because
               excessive vibration or shock sould not be applied to it. If the module is dropped or if
               excessive vibration or shock is applied, the glass panel of the PDP module may be broken
               and the drive circuit may become damaged. The packing for delivering or transporting
               should be made with tough structure.

           (14) When storing the PDP module, you must select an environmentally controlled place. Avoid
               any environmet in which the temperature or humidity exceeds specification values. If you
               are storing it for a long period of time, you must place the module together with a
               dehumidifying agent, such as sillica gel, in a moisture-proof bag and keep it in an
               environmentally controlled place.

           (15) The PDP module is composed of many kind of materials such as glass plate, metals and
               plastics. When you dispose it, you must ask a qualified service technician.

              Notice of the PDP module performance

             The PDP module is the newest display device utilized the gas discharge technology and digital
             signal processing technology, and its performances are mostly similar to the CRT's.
             However, some display performances of the PDP module is different from the CRT's.
             Please consider the following notices when you see the PDP screen.

           (1) There is a slight Neon luminence shown outside of the effective display area on the glass
               panel. Mask this parts so that it may not be seen on the display surface.

           (2) Depending on the type and time of usage, there may be a slight change in the brightness and
              color. There may be an increase of both X-value and Y-value by 0.05 maximum in
              chromaticity. In this case, adjust it using external data signal.

           (3) Because the PDP module uses phosphor to emit light, the phosphor, like a CRT, deteriorates
              in proportion to display signal and brightness settings. If the same pattern is displayed
              continuously (fixed display) for an extended of time, the brightness of that area will be

                                                                 Version 3         33/2         16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com
   Global LCD Panel Exchange Center                www.panelook.com




                                                                                                  S DI
                                                  CONFIDENTIAL
              decreased over non-lit areas due to the fact that the discharge surface will be more activated
              compared to other areas.

           (4) The PDP module is possible to be operated by plural Vsync; 50 , 60       that is called Multi-
              Vsync function. And the PDP screen is scanned according to each frequency, and also PDP's
              subframes to display the grayscale is arranged in this Vsync period. Due to this reason, at the
              low frequency operation especially 50 , you may sometimes find the flickering in the screen .
              But this is not a failure.

           (5) When the Vsync signal timing becomes shorter just after the changing of Vsync frequency
              (e.g. from 50 to 60H) depend on Multi-Vsync function, an initial Vsync signal of the
              changed frequency will be ignored and the PDP screen will be interrupted for maximum 1
              frame period.

           (6) Because the PDP module is a digital processing display devices, this module is equipped with
              Error diffusion technology and Duplicated Sub-Frame method to display the grayscale and
              false contour improvement. However, you may sometimes find a color false contour
              especially in human face contour at moving picture due to difference of display performance
              compared with the TV-tube.

           (7) If the PDP module displays some video test pattern that are mostly used in a laboratory or
              inspection process of the manufacturing facilities, you may find the following subjects. But
              these sujects should not be recognized in the failure or defects because the display
              performance of the PDP module is equipped with Error diffusion technology and Duplicated
              Sub-Frame method based on digital processing technique.

             Linearity in the grayscale test pattern
                If the PDP module displays the grayscale test pattern (e.g. white color brightness is
                gradually changed horizontally or vertically) in a screen, you may find the disparity of
                brightness at adjacent grayscale patterns. This behavior is caused by duplicated sub-frame
                condition, display load correction and electroad dependency.

              Color contouring and dithering at the stationary picture
                If the stationary picture such as a human face or the like is shown in the PDP screen, you
                may feel some unstable noise at the contour area. This behavior is called the color
                contouring or dithering, and is caused by the error diffusion condition, display load
                correction and electroad dependency.

           (8) If the PDP module is operated under inadeqate conditions or harsh environment, the screen
              may become unstable or noisy. This instability is mostly related to ambient temperature, air
              pressure, input signal instability (include signal noise), input power voltage and strong
              magnetic field like a MRI/NMR application or superconducting magnetic application. Please
              don't apply the PDP module to inadequate conditions or harsh environment mentioned above.




                                                                 Version 3         34/2         16/OCT/02




One step solution for LCD / PDP / OLED panel application: Datasheet, inventory and accessory! www.panelook.com



◦ Jabse Service Manual Search 2026 ◦
Jabse PravopisonTap.bg ◦ Other service manual resources online : FixyaeServiceinfo